Loading...
HomeMy WebLinkAboutNOADADE MIAMI-DARE COUNTY, FLORIDA MINA® PRODUCT COM ROL SECTION DEPARTNIENT OF REGULATORYAND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 3 t�2599 NOTICE OF ACCEPTANCE (NOA) RECETI/Fn .miamidadeeov/economv Lawson industries, Inc. 8501 NW 9e Street APR 2 4 2018 .SCANNED Medley, FL 33166 BY .SCOPE: ST. Lucle cow Permitting St. Lucie County This NOA is being issued under the applicable rotes and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AID (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance proposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is a herein, and has been designed to comply with the Florida Building Code, inc Velocity Hurricane Zone. APPROVAL DOCUMENT: Drawing No. L9 000-0901 Rev C, titled "Series SGD-9000 Aluminum Sliding Glass Door (NJ.) No Steel Reinforcement', sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09 and last revised on NOV 21, 2017, signed and sealed by Thomas J. Sotos, P. E., bearing the Miami - Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date - uct Control Section. MISSILE IMPACT RATING: None: Approved Hurricane Protection Devices Complying w/ FBC , as �RNII&cable, are required. CONCEALED FASTENERS OR ATTACHME Limitations: ARE THE RESPONSIBILITY OF THE CONTRACTOR OR 1. See design Pressure chart S lass es 1 ei m s ee _Z. 2. Applicable door egress requirement to be reviewed by Building official LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-0608.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed Ishaq L Chanda, P. E. NOA No.17-1212.06 MIAMFDADECOUNTY c'g72-�` 1�2C Expiration Date: August 26, 2022 ST. LUCIE COUNTY BUILDING DIVISIO val-Date: January25,2018 REVIEWED FOR COMPLIA� e.Arhn Al i oononeonurnoi.REVIEWF�RY— . t� ,J/i Pagel wumcu or n¢w morma ivno i rwi `�I.D HIVU MKMIT MUST BE KEPT ON 10B kY BE NECESSARY IN ORDER TO SITE OR NO INSPECTIONS) WILL BE MADE )MPLY WITH ALL APPLICABLE CODES. Dawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No.'s 99-0517.05 and 09-0706.07) 2. Drawing No. L900"901, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel Reinforcement", sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09, with the latest revision `B", dated 12/19/14, signed and sealed by Thomas J. Sotos, P. E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along with marked -up drawings and installation diagram of an Aluminum Sliding Glass Door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s BETI-09-2534 and HET148-2176, dated 05105109, both signed and sealed by Candido F. Font, P. E. (Submitted under NOA No. 09-0706.07) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, Type "C" sliding door, Grade 10, per FBC 2411.3.2.1, TAS 202-94 and per ASTM F 842-04 along with marked -up drawings and installation diagram of an Aluminum Sliding Glass Door, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTIr2019, FTL-2021, FTL-2023, FTL-2024, FTL-2025, FTIr2028, FTL-2029 and F1Ir2030, dated 01/04/99, all signed and sealed by Gilbert Diamond, P. E. (Submitted under NOA No. 99-051Z05) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by Lawson Industries, Inc., dated 04/28/15, signed and sealed by Thomas J. Sotos, P. E. (Submitted under previous NOA No.14-0908.03) 2. Glazing complies with ASTM E1300-04/ 09 D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Technical data sheet of flexible vinyl compound FPVC 7267-75 (White) & FPVC 7200- 75 (Black), published by Team Plastics. IncJ Bayshore Vinyl Compounds, Inc. a division of Mexichem SAB de CV, LLC Isbaq 1. Chanda, P. E. Product Control Examiner NOA No.17-1212.06 Expiration Date: August 26, 2022 Approval Date: January 25, 2018 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to and complying with FBC 51 Edition (2014), issued by manufacturer, dated 05/24/17, signed and sealed by Thomas J. Sotos, P. E. 2. Statement letter of no financial dtd 011=09, signed and sealed by Thomas J. Sotos, P. E. (Submitted under NOANo. 09-0706.07) 3. Laboratory compliance letter for Test Report No.'s HETI-09 2534 and HETI-08- 2176, issued by Hurricane Engineering & Testing, Inc., dated 05/05/09, signed and sealed by Candido F. Font, P. E. (Submitted underNOWNa. 09-0706.07) 4. Proposal No. 08- 0591, issued by Product Control, dated 07/15/08, signed by Renzo Narciso. (Submitted under NOANo. 12 1204.12) 5. Laboratory compliance letter for Test Reports No_'s FTL-2019, FTIr2021, FTL- 2023, FTL-2024, FTL2025, FTL-2028, FTL-2029 and FTL-2030, issued by Fenestration Testing Laboratory, Inc., dated 01/04/99, all signed and sealed by Gilbert Diamond, P. E. (Submitted under NOA No. 99-0517.05) 6. Proposal issued by Product Control, dated 04/14/98, signed by Jaime D. Gascon, P. E. (Submitted under NOANo. 99-0517.05) G. OTHERS 1. Notice of Acceptance No. 14-0908.03, issued to Lawson Industries, Inc. for their Series "SDG-9000 ST" Aluminum Sliding Glass Door w/o Reinforcement - N.I.", approved on 05/07/15 and expiring on 08/26/17. 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. L90004901 Rev C, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel ReinforcemenY', sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09 and last revised on NOV 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consist of editorial changes of FBC 17 (60' Edition) code compliance. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). haq I. Chanda, P. E. Product Control Examiner NOA No.17-1212.06 Expiration Date: August 26, 2022 Approval Date: January 25, 2018 E-2 Lawson Industries. Inc NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERL&L CERTIFICATIONS 1. None. F. STATEMENTS I. Statement letter of conformance to FBC 2017 (6�h Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. IL OTHER 1. This NOA revises # 17-0608.05, expiring 08/26/22. Ishaq L Chands, P. E. Product Control Examiner NOA No.17-1212.06 Expiration Date: August 26, 2022 Approval Date: January 25, 2018 E-3 TYPICAL Vi EN%T ON TESTED UNIT (OXXX) NOTES: SGD-9000 ALUMINUM SLIDING GLASS DOOR SEE SHEET 2 FOR DESIGN LOAD CAPACITY OF DESIRED PANEL SIZE. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (2014-5th EDITION k 201T-61h ECiOon), WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHAH BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDNENT TO BASE MATERIAL SHALL BE BEYOND WALL ORESSNG OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. NON -IMPACT WITHOUT REINFORCING fR00IICtgEY6P9 A14rtb4�W 4t{lrY4 pe NN-17-121Z•06 BTtLaIa dr�yyt—�y7KlYA- 6 ally DOORS NOT RATED FOR IMPACT,INSTALLATION b01" OF THIS PRODUCT REQUIRES THE USE Of APPROVED .{ASHUTTERS OR EXTERNAL PROTECTION DEVICESRCOMPLYNG 9 WITH HYHZ REQUIREMENTS. N PANEL MGM Rf7H 2 PANELS ONLY (3/I6" TEMP. GLASS) 2 L-9002 I FRAME SILL (2 TRAOf) 60W-76 ALUM. p.NoME NOMINAL DOOR HOGHT 1-3/4" SI ^INT. SILL J L-9003 2 FRAME JAMB (2 TRACK) -TS NUM. PROME C, .-. .: "'11N.3' FTJIN. 2/0 2/6 fT./IN. E(( (}) 40.7 INT. (-) 89.J EXT. (+) 56.7 (-) 89.J IXI. (#) fi7,7 INT, (-) 89.] EXT. (#) 64.5 INT. (-) 893 4 3 L-9004• L-9003 1/ PANEL 1/ PANEL PANEL TOP FAIL PANEL G07TOM RAL 6083-M ALUM, 6053- TS NUM, PROFILE PROFILE u 'a m C n no y e n Y 7^ O 40.7 75.] 58.7 75.1 67.J ]5,3 8 L-9008 AS REDD. LOCI( SOLE / FIXED MILE fio6]-TS ALUM. PROFILE ] L-BOOS A4 ROOD. SwOfE IXfE0.LIX,% SnIE 6a6]-TS ALUM. PROFLE 3 0 8 40.7 66.2 56.7 66.2 63.3 66.2 64.5 66. 8 L-6000 !S RECD. ASIRA6LL 614E 6063-TB ALUM. PROFILE p, c A G (: Ll 4 5 V 40.7 Si4 Si{ 55.4 5i4 55.4 $i4 SS.4Go B L-9013 AS REOD. 3/16' QAZINC CHANNEL TEAM PUSTIM Ina. Sea Mabrgl Compov7fon p Sneel ; 8 2 6 y x O 10.7 49.9 49.9 49.9 49,9 49.9 49.9 4969 fo FS-011 4/ PANEL PANEL ASSY SCREW O TOP RML AID • 5/B' P.M. - PHItt1P3 2/0 2/5 3/0 B/ 0 40.7 72.2 56.7 72.2 63.3 721 64.5 721 II M-034 2/ PANEL PANEL ASSY SCREW 0 BOTTOM RAL 40.7 60.4 56.1 60.4 60.4 W.4 1 60,4 12 FS-020 B FRAME ASSEMBLY SCREW - Ae % 7/16' P.H-PAIL 1] ]519-6001-7 A$ REM. PILE WISP. O JAMB/ASIRAWL - (0.157'w. • 0.200'n.)-SCNN901 40.7 52.5 52,5 $2.$ $2.5 525 525 525 14 7524-601 AS KIM. P WR'P. O TOP RMS - (0.1BYa. • 0.250'n.)-Scn49el O' 410 40.7 43.0 43.0 43.0 410 431L.43.0 43.0 15 7329-MI-7 AS REOD. PILE WTS'P. O SOi104 R,L6 - (O.iB]'r • OADOT.)-Scnle9el 2/6 2/6 9/0 40,7 54.] 54.3 54,3 51.) 543 IB )320-fiDO1-] AS RE00, PILE WR'P. O 0l1ERL.5 (OAR-.* • 0,210'n.)-Sc NNgel �u ® � �I ,7 'Z �' 1017 H.3 44.3 44.3 44.3 41.1 µ,) 44.3 qd.) µ3 17 35 REDO. SILL LASER 6D83-i]9UDONE0 IN PUCE 5/8" TEMP. INSULATED GLASS MAY BE USED IN 4XB' PANELS OR SMALLER. IB L-9010 - ] OR 4 • RXm PANFL JAMB CLIP 806]-i8 NUM, CH_2719] 19 Mm029 I/ CUP RXEO PANEL CLIP SCREW - IS % 3/8' N.-PHI / SDS 20 AR-001 1 FIXED INTERLOCK AN01E 6053-i5 NUM, 01 t 1/21 19/18'A 1/6' 21 AR-002 1 MOMNC INiERLDON ANGLE/CUP 603-75 ALUM. 1 1/2- X 3/4' X 2' X 1/8' \/ 1 < y O 22 L-9022 I ASTRAGAL RETAINER CLIP 8081-T6 NUM. M-10728 DESIGN LOAD CAPACITY - PSF 27 • OPRONN SCREPI 1WB AOWTER MINER 6063-TB ALUM. _ C , O O Co q PANEL WIO7X NOWWU. DOOfl HEIGHT DODRS H17M O OR MORE PANE IS (3/IB' TEMP. GLASS) IB L-9028 1 FRAME NJAM (] 6063_To ALUM, 2a L-9020 1 FRAME SILL (3 TRACK) 600]-TB ALUM. - I-3/4' BILL 2-I/4" SILL 2-I/2' $LL.4 $^ SILL JO L-90]0 2 FRAME JAMB (] TRACK) fi063-fS ALUM. R./IN. iT./IN. (%1. (+) INT. (-) EXT. (#) INT, (-) E%T. (4) INT. (-) EXT. (+) INT. (-) 31 L-2031 AS REGD. DOUBLE IIIERLOCK STILE 6063-T6 ALUM. OpRDNAL 2/6 3/0 4/0 5" 6/8 40.1 11.4 56.7 61.4 61.4 61.4 61.4 61.4 J2 1071. 2/ PANEL PANEL TOP RAL NTLOA GUIDE M801 Nylon 6-8 MPI4e0 NFlan- Rackaell M role: 79 1� V y 40.7 54.0 54.0 54.0 54.0 54.0 54.0 5/.0 ]3 Ion. 2/ PANEL PANEL BOTTOM RAIL N71GN CUM MIDI Neon 6-6 Melded Nylon- Reekwee M rate: 79 40.7 40.7 45.5 40.9 153 10.9 163 10.9 453 40.9 45.) 60.9 453 4D.9 153 40.9 34 NW4-WHL 2/ PANEL PANEL SINSE ROMER 6 COMPONEM - ASSY 150 ]5 38 HC-OJ6 u1-109A AS REO'O. 1/ PANEL DOOR L001 ASSEMBLY 5/0' MSIRAIED PANEL lOP IWl 6083-76 ALUM. INT, OEM. PULLS. GAY, MER PROFILE 2 6 0 10.7 49,2 .2 491 19.2 49.2 49.2 49.2 J] Lli-IfOA I/ PANEL 5/8' INSULATED PANEL BORON MIL fi08]-TS NUN. MOFIig J/0 4/0 40.7 42,9 42.9 d2.9 42,9 12.9 42.9 J8 UI-108 f PANEL SAW INSUATEO PANEL LOCK MILK 6003-T6 ALUM. PROfILF {E J S • S • 8 s d E$ 70.0 J0.0 SOLO 30.0 JD,O 30.0 30.0 30.0 ]9 UI-082 1/ PANEL S/8' INSUUTED PANEL WiENLOCK 0083-i6 AWY, PROFILE 5/8" TEMP• INSULATED GLASS MAY BE USED IN 4X6' PANELS OR SMALLER. 40 UI-I6] 1/ PANEL ]/6' INSULATED PANEL ASTRAGAL 6063-T6 ALUM. PROMS 41 u-1040 AS REOb. POCKET DOOR AUB H00( 0063-T6 ALUM. PROFILE 42 L-9045 AS REO'0, 5/8 INSol GLAZING DRAWN Do TEAM PLASTICS no. See Malelaf Camp.mU O She. -Is 41 812-25N-351 AS R56 TpSrl' Don Seal Sawa Spacer Black - f/V' Xr Space N 9/0 RICH 000 6 ONLY GLASS CAPACITIES ON TKESE CHARTS ARE EASED ON ASM E1300-98 (50 SEC. WIND) T 3116' TEND. CUSS THIS APPROVES DOORS USING TWO (2) OR THREE (3) TRACK FRAMES 1 f9loBOcf21¢yIe® WITH ANY NUMBER OF PANELS THAT CONTAIN THE STILE CONFIGURATION I k' I^olonyw OWFb14 SHOWN ON SHEETS 4 AND B. I.E. XX, OX. XO, XXX. OXO, OXXO. O I -Ai Soon �,cu�ao 17/2/p.pG AND THE FOLLOWING POCKET DOOR CONFIGURATIONS: u II s Ye O'1e�Z M XXp, PXX, XXXP. PXXX, XXXXP. PXXXX, PXXXXP y V $$ OXXXP, PXXXO ,I I 5 n 3 6 /1 TEMP, GLA ZING DETAIL fi/8 TEMP INSUI-•TRO Gtn M DETAIL 44 , d M L p ) e 3f i 4 L TL,1ctn1F�A p]SIT C IS3gJN A�0I.............. '� % • sty '��' s µ0 1 0 on :.� of ;�... r J Di Q O flR a fM T Al O FOR SPACWG ;'a jj('''WcoO'60cK tm: �lIIII®® MR SPACWa FURS VC TYPICAL. ANCHORS IN PMRS SEE ILEV. MR SFI@la WOOD BUCKS AND METAL STRUCTURES NOT BY LAWSON IND. MUST SUPPORT LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. INTO 28Y WOOD BUCKS OR WOOD STRUCTURE 1-3/8' MIN. PENETRATION INTO WOOD THRU 18Y WOOD BUCKS INTO MASONRY OR CONC. 1-1/4' MIN. EMBED INTO MASONRY OR CONC. CTLY INTO CONCRETE OR MASONRY 1- MIN, EMBED INTO CONCRETE OR MASONRY INTO METAL STEEL : 12 0A MIN, THICK- 0.105' (Fy a 36 KSI MIN,) ALUMINUM 1/8' THK. MIN. (6063-T5 MIN.) 410 SMS - GRADE 2 INTO MIAMI-DARE COUNTY APPROVED MULLIONS (MIN. THK.. 1/8') (NO SHIM SPACE) TMPICAL EDGE INSTANCE INTO CONCRETE AND MASONRY a 2-1/2' MIN, REST .10XF.NEO TO INTO WOOD STRUCTURE a I' MIN. (OR AS SHOWN) 'MNI SUCONE INTO METAL STRUCTURE - 3/4' MIN, SUBSTRATES• WOOD BUCK (P.T.) AT HEAD OR JAMBS SO = 0,53 MIN. CONCRETE AT HEAD, SILL OR JAMBS F'e - WOO PSI MIN. C-90 GROUT / FILLED BLOCK AT JAMBS F'm n 210 PSI WIN. ovnals . RANTS ALL FRAME AND PANEL JOINT, INSTALLATION SCREWS AND HEADS OF ANCHOR SCREWS AT SILL TO BE SEALED WITH SEALANT. em N u o z. � -m < x qgos 3�3N�S o �^ 0 yea : DIP W d ?oTIEa SEE F�LEµNR�SPIJ faNC� hhff j N� 1 e � O y O F` m F N i7 � ; 0 2 N wPfl'0 WWON 5 IRS SEE ELEV. RJR SPADNCC emoucFRA'1T® b".,Q. MAtlptHAIli Om 1 1212Of. �jNNty�{ MLLI X� � F sNooa 8sna asr sYoada6 pnx/pnT',6/ MO d0 BHNnL9YdnArop 0998- 69 (SOO '•N Nd - 991SS tl as ' 'A71o311 �® 06 'M'N 1058 �� E7, �a0 f IS, "a'15 52a :d!•. _ ef [�a[ /• w ws w9 _a aas s ae /• wea of n•+wu p a�oz /• • O n W- mlP a+CHORs IN PMIS SEE EIEV. MR SPP=WG wlN ANCHORS IN PMRS NET& SEE EItY. MR SPACING SWIOL. mllS w'PMRS STREICEORE o SEE FLEV. MR SPMNG r me R z .m• WORD Slice 4�+ m (Ne. EUBEG.)tl .. uw.. m • MxiueDx7 A . e' I . . 'A :' \ � � ri' o u � p � Ee Q c7 ] o O A \� IA $ENNE W-DACE fAGN1Y APPR'O NEIELION S Im ANNRgSP. LLYORS nI SEPMGSE NOSI II ii 11 '' nmWi a OR WOOD DIIGR iii D Ii 1316, STR RE lil II 11 {WN USES.) 1 1 i I: 1. d AI P SEE M. . FOR IN SPACING J r II it n $E fLEV. FDR SPACING � Y a I II I vl 4 p 1�ej� �j II i II O ED m i J O a �l g _ = # d N ; III I:I II� 8 � I li II II1 i. 1 D/e• $ W i � 1II (Nn ERSEOI � � ail II POCKET JAMB H4PANEL ttgg LE SILL RSER ADNEREO ED ESISILL & SUCONE ! y$pp O S II .. Ill I< M J f ® 1-D/A. MOVI.JOB 2-I/4• DP110N5 IS 5 2-1�R P RMET A 0.NINO 1 fin. _ - ++lE\G1111Gp1f1f ..........!........ I 1 ERSUDUCCREV680 A:oy aW lee E'YIY.. (Nrn. lilieEwl a� 'NIN •� POCKET DOOR JAMB ANCHOR DETAIL e*". mre m < rY m ANRS LNCCiaYY Nen-SNNY, Nan ft Grout e1 uNimum 5a IW SEE MEN. FOR SPAGINO �> I� .•'• , I THREE (3) TRACK SECTION •• IG+aGGG+�o z e o m O THREE (3) TRACK SECTION 2�ao 1.000 2 TTP. �0 40 . .]>6 L -1 .062 iTP. FRAME HEAD (2) TRACK LOCK STILE 9094 L16By 462 UP. IA00 .060 iTP. .,SB LAID 1.044 FRAME HEAD (3) TRACK E3811 -115mr 2.3TiItr DOUBLE INTERLOCK ])9LI9IL189TTP. L460 PANEL TOP RAIL PANEL BOTTOM RAIL SINGLE INTERLOCK .o 121E zle A62 e 3.500 121E ^� A62 9087 1218 II 421E A62 —(bW SILL RISER FOR 2 @ J TRACKS FRAME JAMB (2) TRACK FRAME JAMB (3) TRACK .599 E.9 9 044 �082 1. INSULATED LOCK STILE INSULATED PANEL TOP RWL .090 2.930 2875 '"5 ug9 .094 .094 •90B i N .3,6 M2 1.656 A62 1696 2.5]3 d IA,S 4.154 B90 AAI] 2250 INSULATED BOTTOM RAIL FRAME SILL (2) TRACK ASTRAGAL STILE 4,B 6q k I.IJ2 4590 494 5.6,2 2313 FRAME SILL (3) TRACK INSULATED INTERLOCK �(S00 1{I42244 B,9 91 F�- 4I2I50-V+r 470 61IA ASTRAGAL RETAINER CUP JAMB i1KED PANEL CUP II FRAME BOTTOM CORNFR t2 IvnoccrMsv�o a 04�lICtRM�04R0MrA e4p.4a. rro TZ L1�IItl IFES RAMV , ENGINEERING, INC. 2100 W 76 ST. #311, HIALEAH, FLORIDA, 33016 FLORIDA BUILDING Robert S. Monsour, P.E. FI # 11955 / 0006024 ASCE 7-10 WIND PDE, DESIGN WIND LOADS (LBS/SQFT) Kd = .85 /~` FOR 170 MPH WIND ZONE Interior & Exterior Zones (4&5 - Walls) Positive Pressures P ��ti eicoo Exposure D For the 170 mph Wind Zone CATEGORY-2 BL'_DG. Effective Wind Area (or, Tributary Area) in Square_Feet Height 10 20 30 40 .'50- 60 Maximum 1.00 0.95 0.92 0.89 / '0:980 0.86 iA, 46.1 44.0 42.8 41.9 /' 41..3, 40.7 2 4 .3 6.1 44.9 44.0 ' -�,4:VV 42.7 5 47.9 46.5 45'.,6-. 9,'9 44.3 30 51.9 49.6 48.2 47.2 46.5 45.9 40 54.6 52.1 50.7 R 49:7..,, `/ 48.9 48.2 50 56.8 1 54.3 1 52.8 1--�, 51.7` ' 50.9 50.2 60 58.6 56.0 54.4• < f'53L37 1 52.5 51.8 •Interior•Zone(4-Walls).Negative.Pressures°' Exposure D For the 170 mph Wlnd`Zone CATEGORY 2 BLDG:. Effective Wind Acea,(or;,Tributary Area) in Square Feet Height 10 20 1,/�30/-� ' 40 50 60 Maximum -1.10 -1.05 °� 5-1:02` -0.99 -0.98 -0.96 1 -5 -4 _ 1 ; `-46.7 -45.8 -45.2 -44.6 o 0:2 - Y49.0 -48.1 -47.4 -46.8 25 -54.4 -521 ; -50.8 -49.8 -49.1 -48.5 30 -56.3 J -54.0 ` -52.6 -51.6 -50.9 -50.3 40 -59.2/ / 256.7 1 -55.3 1 -54.3 1 -53.5 -52.9 50 -61.6`�,; ' � -59r1 -57.6 -56.5 -55.7 -55.0 60 7q&p6 _ \: 60.9 1 -59.4 1 -58.3 1 -57.4 -56.8 1f ( /J__1 Exterior Zones_(5'-Walls) Negative Pressures... Exposure D _ .. ` For the -170 1.mph Wind Zone CATEGORY 2 BLDG. i Effective Wind Area (or, Tributary Area) in Square Feet Height } 110 20. 30 40 50 60 (Maxi 111UM')_-,_7/1.40 -1.29 -1.23 -1.19 -1.15 -1.13 /15, -61.7 -57.6 -55.1 -53.4 -52.1 -51.0 i✓ 20":`e -64.7 -60.3 -57.8 -56.0 -54.6 -53.4 25 -67.1 -62.6 -59.9 -58.1 -56.6 -55.4 ( 30 -69.5 -64.8 -62.1 1 -60.1 1 -58.6 -57.4 \, 40 -73.1 -68.2 -65.3 -63.2 1 -61.7 -60.4 60 -76.1 71.0 -68.0 -65.8 -64.2 -62.8 �, 60 -78.5 -73.2 -70.1 -67:9 -66.2 -64.8 NOTE: AN 8% REDUCTION OF THE LOADS SHOWN ABOVE MAY BE TAKEN FOR FLAT ROOFS. LZength of End Zone (a): 10% of least horizontal dimension or .4 h, whichever is smaller, but not less than 4% of least horizontal dimension or 3 ft. (h = mean roof height in feet).