Loading...
HomeMy WebLinkAboutBUILDING SCHEMATICBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P-SF.) FOR ASCE 7 f0 PEAK ROOF HEIGHT LESS THAN OR E%iJ4L TO 60 FEET ae I BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) r;iz SCANNED��, `, 'Uv ry BY fl r E f .I� St. Lucie County PEAK ROOF I- LESS THAN 7'-9" L** GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" I- GREATER OR EOUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE I A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 5Z3 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 53.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 1077 64.6 773 46.4 9Z4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 0 87.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90. 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 1 78.2 92.9 55.7 121.5 1 72.9 , 8Z2 52.3 709.9 1 65.9 THESE PLANS AND ALL PROPOSE A,RE SUBJECT TO ANY CORREQTED REQUIRED BY FIELD INSPECTORS D WORK . MAY BE NECESSAP.Y IN O THd INDIC47ED DESIGN WIND PRESSURES MHLY WITM ALL, Af'1'LI� DER TO * CORRESPOND TO THE MAXIMUM END AOLE CDDE ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. . L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. _BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (& SF,) F) FOR ASCE 7 10 PEAK ROOF HEIGHT GREATER THAN 60 FEET ar BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L** LESS THAN 12-3" L•" GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 16Z7 100.E 84.3 50.6 148.4 89.0 > 70' - 60' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 5Z4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 9Z3 58.4 178.4 10 89.7 53.8 1579 94.7 1 - t 100.5 60.3 184.2 92.5 55.5 163.0 9Z8 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57.7 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160' - 180' 1078 64.7 1976 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63. 1 185.1 111.1 > 250' - 3D0 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 30O' - 350' 121.0 72.6 221.9 133. 1 111.5 66.9 196.3 1178 > 350' - 400' 123.9 74.3 2271 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123. 1 > 450' - 500' 128.8 1 773 1 236.1 1 141.7 1 118.6 1 71.2 1 208.9 1 125.3 N07F5: I ) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & IXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELEC71ON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WINO PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO L1`1 E REVIEWED BY // DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE ) LE0 FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD *.k* PRODUCTS WHICH BEAR A M/AMI-DADS COUNTY OR A STATE OF FLORM4 APPROVAL PEP'F e i Y•00AI 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & BANANA SHUTTERS *** DRAWN BY RISK GAT. H BLDGS 08109117 11LIEC77c WIND PRESSURE CHART DATE JT TESTING A ENGINEERING COMPANY BAS/C WIND SPEED = 170 mph KW. J61N. SY. 71- J6J. VF4 : WR671- R. J3166 EXPOSURE D, Kd = 0.85 17- 194 Phone : (JO6fe EB-00. 71 : (JOJ)B71-15J1 R[v. Uff .. Ne 66wIlNM arz DRAWING Na EB-0006719 WALTER A 77LLIT Jr. P.E. ' 01O IJ-1BB 71 ' SHEET 1 OF i FLORIDA Uc.:Y 44167 i