HomeMy WebLinkAboutBUILDING SCHEMATICBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS &CLADDING (P•S.FJ FOR ASG� 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET N BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS Ii RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I' LESS THAN 7'-9" L•• GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" I' GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POS/DVE NEGARVE POSITIVE NEGA77VE (h) ULTIMATE A.S.D. ULRMATE A.S.D. ULTIMATE A.S.D. UL77MATE A.S.D. ULTIMATE I A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15' 20' 80.4 48.2 1076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 f077 64.6 773 46.4 974 58.4 > 30'-40' 90.7 54.4 127.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 1177 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 1 58.4 1 130.3 78.2 92.9 1 5.7 1 21.5 1 72.9 1 .2 52.3 1 09.9 1 65.9 THESE PLANS AND ALL PROPOSED WORT: ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIE! D 114SPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICADLE CODES. SCANNED BY St. Lucie County BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F.) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET ak BASIC WIND SPEED = 170 mph RISK CATEGORY l/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L•• LESS THAN 12-3" 1- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.SD. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 574 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 107.4 89.7 538 157.9 94.7 i - la4 100.5 60.3 784.2 0.5 - F92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 189.2 113.5 1 95.1 571 1674 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - 180' 1078 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133. 1 111.5 66.9 196.3 1178 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8 139. 1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 77.3 236.1 141.7 118.6 77.2 208.9 125.3 No I.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES /S COMPLETELY GENERIC AND DOES NOT PROWD£ INFORMADON FOR A SITE SPECIFIC PROJECT. 2.) )HIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE 77ME BUILDING PERMIT Z) COMRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WAD PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE UL77MATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). /'f04 - 05Qgi ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO hgJJyE REVIEWED BY (� DATE U PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDIVONS AND FOR ALL ROOF SLOPES. L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT * No• *167 S^(�iEOf ? i°Cu Lffnk 'Ap'• !�LOR��P`v��•' PRODUCTS WHICH BEAR A MIAMI-DAOE COUNTY OR A STATE OF FLORIDA APPROVAL PE pf (0-) 0j.%GkA CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & IND14N RIVER ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS ACCORDION & B4HAAM SHUTTERS **• DRAWN BY RISK CAT. ll BLDGS 08109117 11 L E C O C. WIND PRESSURE CHART DATE T TEBT/NG & ENGTNEERINQ OONPANY BASIC WIND SPEED = 170 mph 17- T 94 W. 36tn St Sh. M5. WRIM G ENS D. 33166 EXPOSURE D, Kd = 0.85 hone : ejRj671-I630. Fm: (30.)671-1531 wrz x1v. x. otre DRAWING No EB-0006719 WALTER A 77LLIT Jr. P.E. r otn I3-Im h FLORIDA Lie. d 44167 1 SHEET I OF 1