Loading...
HomeMy WebLinkAboutBUILDING SCHEMATICSM OM'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (PIS-F.) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET �r BASIC WIND SPEED = 170 mph RISK CATEGORY 11 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L** LESS THAN 7'-9" L** GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3` L' GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE ASD. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. o' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 > 15' 20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 - 107.7 64.6 773 46.4 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 973 58.4 130.3 78.2 92.9 55.7 121.5 72.9 872 52.3 109.9 1 65.9 BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L** LESS THAN 12-3" 1' GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULBMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 54.9 1677 rl00.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 .0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 107.4 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 571 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160, - 180, 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - JOO' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > J00' - 350' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123. 1 > 45D' - soo' 128.8 773 236.1 141.7 118.E 71.2 208.9 125.3 NOTFS: I.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE_ SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECUON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WINO PRESSURES ARE ULTIMATE AND ASO. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS 5) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPAvo BY THE COMRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). t, Y SCANNED St LucieY Counh, I �OiI - tJSO ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANC , REVIEWED BY DATE PLANS ANDIPWMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD IFISPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, INDIC47ED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM ENO ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR 84MMA SHUTTER HEIGHT t+'•' ............. � JN$~.9 go. A4167 •'i �r PRODUCTS WHICH BEAR A MbWl-DAOE COUNTY OR A STATE OF FLORIDA APPROVAL PR0(fi �� 41 CONCEALED FASTENERS OR AT7ACHMiNTS ARE THE RESPONS3 UUjyopTq CONTRACTOR0FR,=R,,q 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANEL.$ ACCORDION & B4H4M4 SHUTTERS *** DRAWN BY RISK C4T. IT BLDGS 08109117 L E C O I N c. WIND PRESSURE CHART DATE T TESTING & ENGINEERING COMPANY BASIC WIND SPEED = 170 mph 17-194 W. JT sr sl...ms. NAGING OA ' R mles EXPOSURE A Kd = 0.85 Wwn : 1T05)8T1-15T0 . Fu : 1.10.51871-15I1 06Y4R0.W art /6Y. N. p£sG®•d a1L DRAWING N. EB-0006719 WALTER A 77LUr Jr. P.E. 1 a0 1s-f•e /1 r SHEET i OF 7 nnwme r... A ee rwv