HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC. echanical * Electrical * Civil Engineering 7RF-CEIV:ED 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 B Phone (772) 785 - 9888 t@rmK%i�e Email pwelchinc@aol.com N(GQ N March 23, 2018 SG 6� G0uX\,CA St•�'�c�e Re: UDT — Seal Museum Association Shutter Installation 3300 N Highway AlA Fort Pierce, FL 34949 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of the shutter at the above referenced address. Wind speed: V it: 165 mph, V.d: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 183" WIDE X 97" HIGH Shutter Location: (See Attached Sketch) Required Design Pressure: +43.81-58.6 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2017. Shutter shall be FL# 12246.1 Thank you for your attention to this matter. Submitted by: PAU WELCH INC. _ Paul We ch, P.E. Reg. No.29945 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD FILE COPY UDT-SEAL Museum Association, Inc. 3300 N Highway A1A R. Pierce, FL 34949 OPENING WIDTH HEIGHT # 1 183' 97' PAUL NC MECH ELEC CCIVIL ENG. 1984 BILTW i;; ST. #114 PORT SAINT L_ C;;_, FL 34984 PAUL WELCH P,E. FLA REG NO.?9945 MAR, 2 3 2018