HomeMy WebLinkAboutPROJECT INFORMATIONr,
•1.
SCANNED
BY
St. Lucie County
New RVle Canopy Fascia &
red bar for the front and sides
Prima Vista Shell Reimage
100 SE Prima Vista Blvd
Port St Lucie, FL
Canopy Signage Reimage
Proposed Signage
(2) 48" SHELL Pectan Signs @
15.21 SF ea
Total Proposed signage = 30.42 SF
Inage
(3) 7-Eleven signs @16 SF ea
Total existing signage = 48 SF
New 2D flat Canopy Fascia &
red decal for the back
SCOPE OF WORK FOR REIMAGE
Disconnect electric and remove existing (3) 7-Eleven signage from canopy
Remove existing fascia and replace with new Shell fascia and LED band
(no structural change or additional SF)
Install (2) Shell Pectan Signs on front and side facing the streets
Reconnect new signs and led band to existing electric on canopy
Canopq Special i5t, LLC
P.O. Box 5224, Plant aty, Fl. 33563 • (813) 703-68"
June 14, 2018
St Lucie County
Building Department
2300 Virginia Ave
Ft Pierce, FL
Ref: Permit 8Qb 0Z32 & 1804-0734
�M SE Prima Vista Blvd
Port St Lucie FL
Dear Sir/Madam,
Listed below are responses to the same comments for the above referenced permit submittals:
1. Please provide specifications, details and attachment method for the RVle
Shell Fascia
Attached is an additional drawing CS-3 signed and sealed with the details for the ACM install on
the canopy.
2. Please provide specifications and details for the red LED bar
Attached is an additional drawing CS-3 signed and sealed with information for the Red LED Bar
on the canopy.
3. Please provide product data and flame spread information on the plastics
Attached is the fire test report certification from the manufacturer showing compliance with FBC
4. Please provide information on framing shown to attach Shell sign to existing structure
The mounting attachment for the Shell Pectan signs to the existing fascia can be found on the
drawings CS-1 top right corner and CS-2 entire page that were already submitted. There is no
frames involved - the signs are attached with (4) Y. x 7/8 HWH TEK Stitch with bonded neo
washer (grabber) to the existing fascia.
See the attached picture of the sign from another location.
If you should have any questions, please feel free to contact me.
LLC
Anne Dumond
FL License # CBC1259301
FF
AUG 2 4 2018
Permitting Department
St. Lucie County, FL
PolyOne Innovation Center
11650 Lakeside Crossing Ct
St. Louis, Mo 63146
Test Report
Date: May 4, 2015
Log Number: 04/04/2015 HB
Customer: Federal Heath Signs
Contact: John Hirsh
Requested Testing: UL94 HB
Sample Identification: WeatherPro T-30, Red, formed parts
Reference Documents:
1. UL94, Standard for Safety, Tests for Flammability of Plastic Materials for Parts in Devices
and Appliances. 6t' Edition
Sample Preparation: Specimens were cut from customer provided part
Test Results
Units
S ecimen 1
Specimen 2
Specimen 3
Average
UL94 HB
In/min
2.12
2.07
2.20
2.13
Burn Rate
UL94 HB
In/min
<2.95
<2.95
<2.95
<2.95
requirement
Respectfully submitted,
Nancy Concepcion
Manager of Analytical Services and Product Stewardship
AUG 24 2018
Permitting Department
St. Lucie County, FL