Application Type Revision vision 13Y
Code Version 2017 St. Lucie County
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easLernmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Li Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Walter A.. Tillit, Jr. P.E.
the Evaluation Report
Florida License
PE-44167
Quality Assurance Entity
National Accreditation and Management Institute
Quality Assurance Contract Expiration Date
12/31/2018
Validated By
John Henry Kampmann Jr.
Validation Checklist- Hardcopy Received
Certificate of Independence
FL38gR5 COI AMERICANS UUnEEg SYSTEM A$59_4.,_ING_DRAWING
17-107 CERTIFICATE QF INDEPENOENC_E.PDF
FL389 R9 COI AMERICAN SHUTTER SYSTEMS SEDC., INC.
DRAWIN(5117d06 CERTIFI'CATIgN OF I,NDEP-ENDENCEI I),PDF
R3$9RQ 00I AMEAMERICAN SHUTTER SYSTEMS DRAWING_17_1QB
CERTIFICATE OF INDEPENDENCE PDF
Referenced Standard and Year (of Standard)
Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
https://floridabuilding.org/pr/pr_app_dti,aspx?param=wGEVXQwtDgvYYHH2vJvx53 Mws... 1 /3/2018
Florida Building Code Online
Sections from the Code
Page 2 of 3
Product Approval Method Method 1 Option D
Date
Submitted
09/18/2017
Date
Validated
10/18/2017
Date
Pending FBC Approval
10/19/2017
Date
Approved
12/12/2017
FL # I Model, Number or Name
389.1 Bertha HV Accordion Shutter -
Blade 3 - (Non-HVHZ) - Drwg 17-
108
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D".Max span Is 12'-3" for 40 psf
positive ASD load and 13'-0" for 35 psf negative ASD load
the HV3 blade w/o window blade,5'-2" for 110 psf ASD load
for HV3 blade w/o window blade and 8'-11" for 62 psf, 9'-
11" for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79" for max. ASD
pressure rating of+72,-72 and 84" for+64,-64 psf. See
sheet 5 for other spans and ASD pressures.
Description
Extruded aluminum interlocking blades retained by tracks
(top and bottom) for storm protection
Installation Instructions
FL389 R9 11 AMERICAN SHUTTER SYSTEMS DRAWING
1717=108 BERTHA HV ACCQRDION $HUTTERSYSTE_M--.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS DRAWING
17-108 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
389.2 Bertha HV Accordion Shutter -Blade I Extruded aluminum interlocking blades retained by tracks
1 Only- (Non-HVHZ)- Dryig 17-107 (top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span is 16'-0" for 30
p.s.f negative ASD load depending on centermates and
locking rod configuration for the HVl blade, 8'-0" for+64,
-72 p.s.f. A.S.D. load for HV blade for Keystone mountings
7'-0" p.s.f. for metals stud mountings and 8'-0" for 110
p.s.f. for HV1A working in unison. See sheets 7, 11 and 20
respectively of installation drawings for other spans and
Installation Instructions
FL389 R9 If AMERICAN SHUTTER SYSTEM ASSOC
IS— DRAWING _17-107 BERTHA HV AI'CORDDD(SHUTT_ER
SY_STEM.P_DF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEM AS$OC_,
INC. DRAWING I7-107 PRODUCT OF EVALUATION
REPORT_PDF
Created by Independent Third Party: Yes
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO- (Non-HVHZ)- Drwg 17- (top and bottom) for storm protection
106
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile. Max. 16'-0" span at 30 p.s.f ASD load
for Blade 1 and 18'-0" for Blade 2. See schedules on sheet
12, 25 and 28 respectively
Installation Instructions
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AIEAMERICAN SHUTTER SYSTEMS ASSOC_
INC. DRAWING 17-1-106 PRODUCT EVALUATION
RE2QRT_PDF
Created by Independent Third Party: Yes
Back Next
Cal Uz :: 260I Blalr stone Road Tallahassee32399 Duane, 850.487-1824
The State of Florida is an AATE0 employer. Coovrloht 2007-2011 state of Florida,:: Privacy statement :: Acce55ibi1jty statement:: Refund eStammon
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records meues4 do not send
electronic mal to this entity. Instead, contact the Office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
section 455.275(q, Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the publiC. To determine if you are a licensee under
Chapter 455, F.s., please dick here .
Product Approval Accepts:
bttps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE V XQwtDgvYYHH2vJvx53 Mws... 1 /3/2018
Florida Building Code Onl;--
Page 3 of')
—1 INIMI
Credit Card
Safe
https://floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx53Mws... 1 /3/2018