HomeMy WebLinkAboutPRODUCT EVALUATION REPORTSCANNED
BY 398 East Dania Beach Blvd
BUILDING DROPS St. Lucie County Suite338
Dania Beach, FL 33004
A Perfect Solution in Every Drop
954.399.8478 PH
Certificate of Authorization: 29578 954.744.4738 FX
-
contact@ buildingdrops.com
Product Evaluation deport
Of
JELD-WEN, inc.
Contours Premium Steel Wood Edge
Full Lite Inswing Door
for
Florida Product Approval
Report No. 3791
Current Florida Building Code
Method: 1 — A (Certification)
Category: Exterior Door Assembly
Sub — Category: Swinging Exterior Door Assemblies
Product: Contours Premium Steel Wood Edge
Full Lite Aron -Impact Inswing Door
Material: Wood/24 Ga. Steel
Product Dimensions: 12'-0"x V-8" (Maxinwin)
Prepared For:
.11?t,li-i'6'1?N; inc.
3737 i_akeport 131vd.
Klamath Falls, 012. 97601
Prepared by: F ruo����''
Hermes F. Norero. P.E. .����� •
Florida Professional En-incer # 73778 p
Date:06/IQ/li 7&
Contents:
Evaluation Report Pages 1 — 5 T
Digitally signed by Hermes F. Norero, P.E. O • ,• C O
Reason: I am approving this document i T� ••.,,..•'' c�
.. Date: 2015.06.12 13:09:00 -04'00' ��'��s`S/ONAL \\��
HermrR'P orero, P.E.
Florida No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Manufacturer: JELD-WEN, inc.
P.roduc[Category:
Product: Sub -Category:
Compliance Method:
Product.Name:
Scopes
limits of Use:
Exterior Door Assembly
Swinging Exterior Door Assemblies
State Product Approval Method (1)(a)
Date: 06/10/15
Report No: 3791
Contours Premium Steel Wood Edge Full Lite Non -impact Inswing Door
(Non -Impact)
12'-0" x 6,-8"
This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) forJELD-WEN inc.
based on Method la of the State of Florida Product Approval, Department of Business and
Professional Regulation - Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions A008730, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the "High Velocity Hurricane Zone' (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing A008730 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions A008730 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 5
BUILDING DROPS
A Perfect Solution in Every Drop Date: 06/10/15
Certificate of Authorization: 29575
Report No: 3791
Certification Agency: The manufacturer has demonstrated compliance of manufacturing products under a
quality assurance program audited by an approved quality assurance entity through
National Accreditation & Management Institute, Inc. (FBC Organization #QUA1789)
Performance Standards: The product described herein has been tested per:
TAS 202-94
a ASTM E 330-02
• ASTM E 283-04
a ASTM E 331-00
Referenced Data
Reports to qualify use of 25 Ga. Steel bottom rail:
1. Product Testing performed by National Certified Testing Laboratory, Inc.
(FBC Organization # TST1589)
Report #: NCTL-110-11987-1, Report Date: 04/06/2009
2. Product Testing performed by National Certified Testing Laboratory, Inc.
(FBC Organization # TST1589)
Report #: NCTL-110-11988-1, Report Date: 04/06/2009
Reports to qualify use of 1.688" x V wood bottom rail:
3. Product Testing performed by Certified Testing Laboratories, Inc.
(FBC Organization # TST1577)
Report #: CTLA718W, Report Date: 11/18/2001
the use'of either the 25 Ga. Steel or wood bottom rail is permitted for use with steel door at the design pressures
listed herein.
4. Certification Agency
National Accreditation & Management Institute, Inc.
(FBC Organization #QUA1789)
5. Component Material Testing of Dylite Expandable Polystyrene by
Intertek Testing Services NA, Inc.
ASTM E84-08
Report4:31137265AT-001 R1 Report Date:03/13/2009
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 5
A �
BUILDING DROPS
j A Perfect Solution in Every Drop Date: 06/10/15
Certificate of Authorization: 29578 Report No: 3791
6. Component Material Testing of ODL HP Polypropylene (Spartech PP5330-C13
& BASF HP -Pro) by Testing Evaluation Laboratories, Inc.
ASTM D 1929-96, ASTM D 2843-99 ASTM 635-03, ASTM G26-95
& ASTM D 638-03
Report #: TEL 013110297-A,B,C,&D Report Date: 12/01/2010
Report #: TEL 013110299-A,B,C,&D Report Date: 12/01/2010
EgUivaieirce of Test Standards:
Various test standards have been evaluated for differences in test methodology, if any, between tested
editions of the test standards listed below and those editions referenced in the current Florida Building Code
Jeld-Wen, Inc. has tested their products to the following test standard edition(s):
1)
ASTM D635-03
2)
ASTM D1929-96
3)
ASTM E84-08
4)
ASTM G26-95
Chapter 35 of the current Florida Building Code references the following editions of the above mentioned
test standards:
1) ASTM D635-06
2) ASTM D1929-96(00)e01
3) ASTM E84-09
4) ASTM G155-05a
After review of the above mentioned referenced standards and editions, it has been found that no significant
technical changes have been made to the test standards that would affect the results. All referenced
standards have been found to be equivalent. All materials test results meet minimum requirements of the
current FBC including HVHZ provisions.
11 n
BUILDING DROPS
A Perfect Solution in Every Drop Date: 06/10/15
Certificate of Authorization: 29578
Report No: 3791
Installation: 1. Approved anchor types and substrates are as follows:
Through Frame Installation:
A. For 2x wood buck substrate, use #10 Wood Screw type installation anchors of sufficient
length to achieve a minimum embedment of 1.50" into the wood substrate.
B. For concrete or masonry substrate where one by (1X), non-structural, wood bucking is
employed, use 3/16" diameter ITW Tapcon type concrete screw anchors of sufficient
length to achieve minimum embedment of 1.25" into concrete or masonry.
C. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16"
diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve
minimum embedment of 1.25" into concrete or masonry.
Refer to Installation Instructions (A008730) for anchor spacing and more details of the installation
requirements.
Qesign'Pressure: Using Surface Bolts:
Design Pressure
Positive 66 PSF
Negative 66 PSF
Without using Surface Bolts:
Design Pressure
Positive 55 PSF
Negative 55 PSF
Installation Methods:
Refer to Installation Instructions (A008730) for installation methods, anchor locations, and more
details of the installation requirements.
Hermes F. Norero, P.E.
Florida No. 73778
Page 5 of 5