HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553
Certification for Design Load Compliance SCANNED
Project Name: S l 4 N 9 atJ6 Jir'CL20 $ BY
ir. ucle County
Project Address: l0J S 3 s, �w Y
Permit#: Occupancy Type: {`!. ConstructionType:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of rec
• Submit (2) copies for residential, (3) copies for commercial with all permit ap VIL
th
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
(complete all that apply)
1. DESIGN CODE: Florida V&3 - Code 2010 Edition with 201v_Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed X Partially Enclosed _Open
3. Risk Category: _I X II _III —IV Exposure Category: x B _C _D
4. Design Wind Velocity !Poo mph jZ- ASD _LRFD End Zone Width: fit
5. Mean Roof Height l0 ft Roof Pitch: 1 :12 Parapet: -1 h ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
{W.7 +'47. 7
Zone 1: )• Zone 2: M tk_ Zone 3: JAb\ Zone 4;. &P, o Zone 5: -37.o Garage: N N
7. Design Loads: Floor: N Gp PSF Roof/Dead: N Ft, PSF Roof/Live: 'd b�- Balcony: N 4 PSF
Dock: 0 N PSF Deck: i.) )f PSF Stairs: IJ (i,- PSF Fence: W N— PSF Railings: Ek PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? A Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: y-Soo PSF Soil Test Reports Submitted? No Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
/ /
Signature, Ofe, and Seal
6/
SLCC6V Form # 020-12 Revised 3/15/12 (JS)
L f zvE Y o rtt� Va 3zeM
Print Name Cent # & Co. Cert Auth.
lG P�� LNG•
Company Name & Address