June 10, 2009
To: St. Lucie County Bldg Dept.
Re: Harbour Ridge Pool House Column
12600 Harbor Ridge Blvd.
Palm City, FL 34990
To Whom It May Concern:
THESE PLANS AND ALL PROPOSED WORK.
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
9Phi 04IVIt" AI.16APPMP Ake 88DES.
Replace rusted steel column with 8"x 8" filled block with #1. Use #5 vertical Epoxy #5
Dowels at bottom & top with 6" embedment and 24" lap at vertical steel. This meets
FBC 2007 with 2009 amendments.