HomeMy WebLinkAboutAPPLICATION FOR CONSTRUCTION PERMIT0
0
STATE OF FLORIDA PERMIT
DEPARTMENT OF HEALTH DATE PAID:
ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM RECEIPT #: 0
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
[v/] New System [ 1 Existing System [ ] Holding Tank [ ] Innovative
[ ] Repair [ ] Abandonment [ ] Temporary [ ]
APPLICANT: Anthony & Ann Mane Piolunex
AGENT: Alexander J. Piazza PSM, Inc.
MAILING ADDRESS: 619 SW Biltmore Street, Port St. Lucie, Florida 34983
TELEPHONE: 772-340-7770
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489-.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: 36-37 BLOCK: 5 SUBDIVISION: Indian River Estates Unit 5 PLATTED: 1958
PROPERTY ID #: 3402-606-0034-000-0 ZONING: R I/M,yO�R EQUIVALENT: [ No ]
PROPERTY SIZE: 0.909 ACRES WATER SUPPLY: 0- PRIVATE PUBLIC I J<=2000GPD [ 1>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ No -] DISTANCE TO SEWER: - FT
PROPERTY ADDRESS: 5115 Palmetto Drive, Fort Pierce, FLORIDA
OUANNED
DIRECTIONS TO PROPERTY: SEE MAP Sy
BUILDING
Unit Type of
No Establishment
1 RESIDENCE
Lucie County
[v(] RESIDENTIAL [ ] COMMERCIAL
No. of Building Commercial/Institutional System Design
Bedrooms Area Sqft Table 1, Chapter 64E-6, PAC
3 1,986
2
3
4
[ ] Floor/Equipment Drains [✓l. Other (Specify) GARBAGE GRINDERS/DISPOSALS
SIGNATURE: Lam' J% /1<'� DATE: 8-24-2017
DH 4015, 06/09 (Obaole�s--previous editions'which may not be used)
Incorporated 64E-6.001, FAC Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM SCANNED
BY
St. Lucie County
M.d
PERMIT #:56-SF-1787193
APPLICATION #:AP1305839
DATE PAID:
FEE PAID:
RECEIPT #
DOCUMENT #: PR1075814
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: Anthony & Ann Marie Piolunex
PROPERTY ADDRESS: 5115 Palmetto Dr Fort Pierce, FL 34982
• LOT: 36-37 BLOCK: 5 SUBDIVISION: Indian River Estates
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
-• PROPERTY ID #: 3402-606-0034-000-0
[OR'TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64£-6, F.A.C.
DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC
PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF
THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY
RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT
THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [` 900 ] GALLONS / GPD SeDtic new
CAPACITY
A L I GALLONS I GPD N/A
CAPACITY
N { - ] GALLONS GREASE INTERCEPTOR CAPACITY
[MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [" ] GALLONS DOSING TANK CAPACITY [
]GALLONS @[ ]DOSES PER 24 Has #Pumps [ ]
D [ 500 1 SQUARE FEET Dralnfleld new SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [XI MOUND [
I CONFIGURATION: I ] TRENCH [X] BED [ ] --
N
F LOCATION OF BENCHMARK: NID E side Of Rd SE Corner
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
14,
0
T
rH
E
A
[ 3.00 ] [1 INCHES FT ] [ ABOVE
[ 2.00 ] [ INCHES FT ] [ ABOVE
BENCHMARK/REFERENCE POINT
BENCHMARK/REFERENCE POINT
•ILL REQUIRED: [1W.UU] INCHES EXCAVATION REQUIRED: [ 40.UU] INCHES
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of
300,gpd.
The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with
s. 64E-6.013(3)(0, FAC.
SPECIFICATIONS BY: Brian J In am
TITLE: Environmental Specialist II
APPROVED BY:
TITLE: Environmental Specialist II
St. Lucie CHD
Brian J In n
DATE ISSUED:
09/19/2017
EXPIRATION DATE:
03/19/2019
DH 4016, 08/09
(Obsoletes all previous
editions which may not be used
Incorporated:
64E-6.003, FAC
I1 lie Copy
Page 1 of 3
v 1.1.4
A 1305839 SE1047339
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569,and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4062 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a 'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
STATE OF FLORIDA APPLICATION # AP1305839
DEPARTMENT OF HEALTH PERMIT # 56-SF-1787193
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #SE1047339
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: Anthony & Ann Marie Piolunex SCANNFn
CONTRACTOR / AGENT: Alexander J. Piazza PSM, Inc BY
LOT: 36_37
BLOCK: 5
SUBDIVISION: Indian River Estates ID#: 3402-606-0034-000-0
County
• TO HE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
.PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.91 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 2275.02 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 750.00 .SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT
BENCHMARK/REFERENCE POINT LOCATION: NiD E side of Rd SE corner
ELEVATION OF PROPOSED SYSTEM SITE 3.00 [ INCHES / FP ] I ABOVE / BEE] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT DITCHES/SWALES: 100 FT NORMALLY WET: [ ]YES [X1NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 77 FT NON -POTABLE: FT
BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 31 FT POTABLE WATER LINES: 10 FT
SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? I ]YES IXIN0]
10 YEAR FLOOD ELEVATION FOR SITE: FT MSL / NGVD ] SITE ELEVATION: FT I MSL / NGVD
n+T. mmnWTT4 TwT n9M TTnV eTTR 1 ROTT, RROFTTX.. TNFORMATTDN SITE 2
USDA SOIL SERIES:Waveland fine sand
Munsell #/Color Texture
Depth
1 OYR 411
Sand
0 To 5
1 OYR 5/1
Sand
5 To 31
1 OYR 6/1
Sand
23 To 37
1 OYR 2/1
Spodic Material
37 To 45
1 OYR 614
Sand
45 To 49
1 OYR 3/1
Sand
49 To 59
.HOLE CAVING
Refusal
69To72
USDA SOIL SERIES:Waveland fine send
Munsell #/Color Texture
Depth
1 OYR 4/1
Sand
0 To 4
1 OYR 511
Sand
4 To 27
IOYR 6/1
Sand
23 To 38
10YR 211
Spodic Material
38 To 44 _
1 OYR 413
Send
44 To 49
1 OYR 311
Sand
49 To 59
1 OYR 3/3
Sand
59 To 62
HOLE CAVING
Refusal
62 To 72
OBSERVED WATER TABLE: 36.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE:
ESTIMATED WET SEASON WATER TABLE ELEVATION: 23 INCHES [,ABOVE / BELOW I
HIGH WATER TABLE VEGETATION: I ]YES IX]NO MOTTLING: [X]YES [ ]NO
[ PERCHED / APPARENT ]
EXISTING GRADE
DEPTH: 23.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: 45
DRAINFIELD CONFIGURATION: [ ] TRENCH EX] BED [ ] OTHER (SPECIFY)
r REMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soil borings.
10YR5/1 stripping In 10YR511 matrix >10% with diffuse boundaries starting @ 23" in S87.
S81 3" below BM. SB2 2" below BM
SITE EVALUATED BY:
Ingram, Brian (TI r Environmental Specialist II) (ENVIRONMENTAL HEALTH)
DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, SAC
INCHES
DATE: 09/05/2017
Page 3 of 4
AP1305839 EID1787193 v 1.0.2
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATIONS
PERMIT #. 56 `5,� 17 �Ih
APPLICANT: Anthony & Ann Mane Piolunex AGENT: Alexander J. Piazza PSM, Inc.
LOT: 36-37 BLOCK: 5 SUBDIVISION: Indian River Estates Unit
PROPERTY ID # : 3402-606-0034-000-0 [ Tax ID Number ]
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE
PLAN:
l✓] YES [ ]
NO NET USABLE AREA AVAILABLE: 0.909
ACRES
TOTAL ESTIMATED SEWAGE FLOW.
500
GALLONS
PER DAY [RESIDENCES -TABLE I /OTHER -TABLE 2
]
AUTHORIZED SEWAGE FLOW:
GALLONS
PER DAY [ 1500 GPD/ACRE OR2500 GPD/ACRE
]
UNOBSTRUCTED AREA AVAILABLE:
750
SQFT
UNOBSTRUCTED AREA REQUIRED: 750
SQFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF PROPOSED SYSTEM SITE IS 34 [INCHES/PT ] [ABOVE/BELOW] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: 100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ [ YES [✓l NO
WELLS: PUBLIC: 200 FT LIMITED USE: 100 FT PRIVATE: 75 FT NON -POTABLE: 100 FT
BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT
SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? I ] YES [✓] NO
10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD
SOIL PROFILE
TEXTURE
USDA SOIL SERIES:
TO
TO
SOIL PROFI" L14 C'VRMA'I'1VV S1'1'z c
MUNSELL #/COLOR TEXTURE DEPTH
TO
TO
TO
TO
TO
TO
TO
TO
TO
USDA SOIL SERIES:
OBSERVED WATER TABLE:40+ INCHES [BELOW r] EXISTING GRADE. TYPE:[ PERCHED /APPARENT
ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [.ABOVE/BELOW ] EXISTING GRAD]
HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ ] YES [ ] NO DEPTH: INCHEI
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION: INCHEI
DRAINFIELD CONFIGURATION: [✓] TRENCH -- [.-,]..BED [ ] OTHER (SPECIFY)
REMARKS/ADDITIONAL CRITERIA: -
SITE EVALUATED BY:
8-24-2017
DH 4015, 12/11 (Obsoletes previous editions -which may not be used) Incorporated: 64E-6.001,FAC Page 3 of
• �(�-5 _178703
APPLICANT'S
Anthony & Ann Marie Piolunex
LEGAL DESCRIPTION: Lots 36 & 37, Block 5; Indian River Estates Unit 5
I certify that there are no potable private wells within 75 feet of the available area for the
proposed septic system, that there are no non -potable wells within 50 feet of the available area
for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated
building foundation, that there are no public wells that serve less than 25 people or less than
15 homes or businesses within 100 feet of the proposed septic system, that there are no public
wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of
the proposed septic system, that the water line from the water meter or well to the structure is
at least 10 feet from the available area for the proposed septic system unless the plans show
the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or
vacuum sewage line in a public easement or right-of-way that abuts the property, that there
are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the
proposed septic system unless the property was created prior to 1972, that the septic system is
proposed on the side of the lot farthest from surface water, that all private wells, septic
systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot
are shown on the site plan, that all public wells within 200 feet of the applicant's lot are
shown on the site plan, and that the location of building or residences, swimming pools,
recorded easements, paved areas or driveways, sidewalks, the general slope of the property,
filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or
Wetlands are shown on the applicants lot.
The natural grade elevation in the area of theproposed septic system and the benchmark must
be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic
system.
NOTE: MUST BE CERTIFIED BY A FLORIDA
REGISTERED SURVEYOR OR ENGINEER.
CERTIFIED BY: -iF
FLOPMA PROFES$IONAI�; ' -,6330
DATE: 08/24/12 JOE NO 17-3255