HomeMy WebLinkAboutNOAHIAM1 D . ,�-, SCANNED BY St. Lucie County DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DMSION NOTICE OF ACCEPTANCE LAPOLLA Industries, Inc. 15402 Vantage Parkway East Suite 322 Houston, TX 77032 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 ww .miamidade.-ov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance_purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Spray Polyurethane Foam — Foam Lok LPA 2500, 2800, 3000 over Steel Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. , INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0605.07 and consists of pages I through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0404.08 MIAMFDAOE CouNTY - Expiration Date: 06/12/18 ppp Approval Date: 06/20/13 `rFl � Qy@[rry� Page l of 6 4[t � R ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Spray Applied Polyurethane Roof System Materials: Polyurethane Deck Type Steel Maximum Design Pressure-212.15 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specifications Product Description Foam-LOK LPA 2500 2.5 lbs/ft3 density TAS 110 Polyurethane spray applied foam that utilizes an HFC blowing agent intended for roofing applications. Foam-LOK LPA 2800 2.8 lbs1W density TAS 110 Polyurethane spray applied foam that utilizes an HFC blowing agent intended for roofing applications. Foam-LOK LPA 3000 .3.0 lbs/ft3 density TAS 110 Polyurethane spray applied foam that utilizes an HFC blowing agent intended for roofing applications. Therm-0-Flex TF 1000 N/A ASTM D6083 A premium quality, fluid applied elastomeric Series Elastomeric Roof roof coating. Coating RCS-5000 Series N/A ASTM D6083 A premium quality, fluid applied elastomeric Restoration Coatings roof coating. Therm-0-Prime N/A A single component, water soluble acrylic emulsion primer to prepare Galvanized Metal, Concrete, Asphalt Substrates and Scarified Foam for new SPF installations. LPA 100 Foam Adhesive N/A ASTM D 1623-09 A:Two component low rise foam adhesive TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Dimensions Specifications Description Manufacturer Any Miami -Dade N/A As Required by Roof coating for application over Generic. County Approved Miami -Dade polyurethane spray.applied foam. (with current PCA) Roof Coating County PCA NOA No.: 13-0404.08 MI/1MIDADE COUNTY Expiration Date: 06/12/18 Approval Date: 0620/13 Page 2 of 6 EVIDENCE SUBNIITTED: Test Agency Test Identifier Test Name/Reyort Date PRI Construction Materials Technologies LPII-007-02-01 TAS 110 01/27/10 LPII-008-02-01 TAS 110 01/27/10 LPII-005-02-01 TAS 110 06/12/07 PRI Asphalt Technologies LPII- 002-02-01 ASTM D 6083/TAS 114-H 10/19/05 Underwriters Laboratories 07NK08120 UL 790 07/16/07 R14353 Fire Classification 06/26/05 Factory Mutual Research Corp. 3023796 Class 4470 10/02/05 Atlantic & Caribbean Roof 07-078 TAS 114-J 12/05/07 Consulting, LLC 08-002 TAS 114-J 02/24/08 ACRC 11-055 TAS 114-D 10/29/12 PRI Construction Materials Technologies LPII 009-02-01 ASTM D 1623-09 03/29/11 LPII 009-02-01 ASTM D 1929-26 03/29/11 LPII 009-02-01 ASTM D 2842-06 03/29/11 LPII 009-02-01 ASTM D 1622-08 03/29/11 LPII 009-02-01 ASTM D 1621-10 03/29/11 LPII 011-02-10 ASTM C 273-00 08/01/11 Intertek 100314102 SAT- ASTM E84 09/06/11 003 C NOA No.: 13-0404.08 Expiration Date: 06/12/18 Approval Date: 06/20/13 Page 3 of 6 APPROVED ASSEMBLIES: Deck Type 2: Steel Deck Description: Minimum 22 ga. 1.5" type B G-96 Steel Deck with maximum 6' spans secured to the deck supports with Tek 5 SD screws 6" o.c. (every rib). Side laps secured with #12 self drilling screws at 12" o.c. System Type A(1): Sprayed polyurethane foam covered with an Approved Miami -Dade County roof coating applied directly onto primed steel deck. All General and System Limitations apply. Surface Metal surfaces should be primed with Therm-0-Prime according to LAPOLLA Industries, Preparation: Inc. and coating manufacturers' recommendations. Primer shall be thoroughly cured prior to application of foam. For ferrous metal, remove loose rust and unsound primer from shop -primed iron and steel surfaces by scraping, wire brushing or sandblasting. Prime according to LAPOLLA Industries, Inc. and coating manufacturer's recommendations. For non-ferrous metals, clean and prime aluminum, copper and stainless steel surfaces as recommended by LAPOLLA Industries, Inc. Primers shall be applied in accordance with their manufacturer's instructions. All primers must be thoroughly dry and cured prior to foam application Polyurethane Foam The polyurethane foam shall be applied uniformly over the entire surface at the specified Application: thickness in compliance with the requirements set forth in o n pplicationsStandazd I2AS JD _ The sprayed polyurethane foam shall be feathered at the edges to produce a smooth transition. Protective Coating Shall apply a Miami -Dade County approved roof coating with a current NOA applied in Application: accordance with the guidelines listed in the NOA:' Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other materials that will impair adhesion of the protective coverings. Any damage or defects to the polyurethane foam surface shall be repaired prior to the coating application. The coating shall be applied the same day as the foam when possible. If more than 72 hours elapse prior to the application of the coatings, the polyurethane foam shall be inspected for UV degradation. Maximum Design -120 psf Pressure: NOA No.: 13-0404.08 Mintn•DnoecouNrr Expiration Date: 06/12/18 Approval Date: 06/20/13 Page 4 of 6 Deck Type 2I: Steel, Insulated Deck Description: Minimum 22 GA. Type 13- 1.5" WR G90 System Type A(2): Sprayed polyurethane foam covered with an Approved Miami -Dade County roof coating applied to .5" DensDecic adhered with Foam Adhesive directly onto a steel deck. All General and System Limitations apply. Surface For ferrous metal, remove loose rust and unsound primer from shop -primed iron and steel Preparation: surfaces by scraping, wire brushing or sandblasting. Prime according to LAPOLLA Industries, Inc. and coating manufacturer's recommendations. For non-ferrous metals, clean and prime aluminum, copper and stainless steel surfaces as recommended by LAPOLLA Industries, Inc.. If Required, primers shall be applied in accordance with their manufacturer's instructions. All primers must be thoroughly dry and cured prior to foam application. Insulation Install %2" thick DensDecic to 22 gauge Steel deck in LAPOLLA LPA 100 Roofing adhesive Attachment: applied in W wide ribbons at every top flange of the deck. Polyurethane Foam The polyurethane foam shall be applied uniformly over the entire surface at the specified Application: thickness in compliance with the requirements set forth in Roofing Application Standard RAS 109. The sprayed polyurethane foam shall be feathered at the edges to produce a smooth transition. Protective Coating Shall apply a Miami -Dade County approved roof coating with a current NOA applied in Application: accordance with the guidelines listed in the NOA. Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other materials that will impair adhesion of the protective coverings. Any damage or defects to the polyurethane foam surface shall be repaired prior to the coating application. The coating shall be applied the same day as the foam when possible., If more than 72 hours elapse prior to the application of the coatings, the polyurethane foam. shall be inspected for UV degradation. Maximum Design -212.5 psf Pressure: NOA No.: 13-0404.08 nu�nEonoeeouNn Expiration Date: 06/12/18 Approval Date: 06/20/13 Page 5 of 6 C TABLE 1 AMBIENT HUMIDITY APPLICATION LIMITS SPRAYED POLYURETHANE FOAM LAPOLLA Industries, Inc. Air Temp/ Humidity/ Dew Point Guideline 110 100 90 80 70 60 50 40 30 Dewpoint and relative humidity forgiven dry bulb temperature. 45 67 40.5 50 70 45.5 55 72 50.5 60 75 55.5 a Airl 45 50 55 60 6.5 70 75 80 85 90 95 100 ♦ Hui 67 70 72 75 78 80 78 75 70 64 58 50 f Deg 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 77 79.5 82 83 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job -Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with LAPOLLA Industries, Inc. published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating: S. All attachment and sizing of perimeter Bailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). END OF TI3IS ACCEPTANCE NOA No.: 13-0404.08 Expiration Date: 06/12/18 Approval Date: 06/20/13 Page 6 of 6 i. 7PRODUCT MIAMI-DADE COUNTY CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Fit LAPOLLA Industries, Inc. 15402 Vantage Parkway East, Suite 322 Houston, TX 77032 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHD may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Therm-O-Flex TF 1000 Series Elastomeric Roof Coating. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewalapplication has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. ` INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0726.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 16-0525.09 Expiration Date: 08/09/21 Approval Date: 07/21/16 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Cement -Adhesive -Coatings Materials: Elastomeric SCOPE: This approves "Therm-0-Flex TF 1000 Series Elastomeric Roof Coating" as a maintenance roof coating as manufactured by LAPOLLA Coatings, as described in this Notice of Acceptance, designed to comply with the Florida Building Code, High Velocity Hurricanes Zone. EVIDENCE SUBMITTED: Test Agency Underwriter Laboratories, Inc. Factory Mutual Research Corp. PRI Construction Materials Technologies, LLC Test Identifier Test Name/Report Date R14353 UL 790 12/15/11 3023796 Class4470 10/02/05 LPII- 013-02-01 ASTM D 6083 01/10/12 TT-C-555B MANUFACTURING LOCATION: 1. Houston, TX. PHYSICAL PROPERTIES OF COMPONENTS Trade names: Therm-0-Flex TF-1001(White), TF-1002(Grey), TF-1003(Tan) Thickness: Wet Film per Coat: 24 mils Dry Film per Coat: 13.2 mils Specifications: ASTM D 6083 Description: A water -based eastomeric coating membrane applied at an application rate of; • Galvanized Metal Roofs: Apply Base Coat at a rate of 1.5 to 2 gal/100 ftZ and Finish Coat at a rate of 1.5 to 2 gal/100 A. • SBS Modified Bitumen Granule Surfaced Membranes: Apply Base Coat at a rate of L.5 to 2 gal/100 ftZ and Finish Coat at a rate of 1.5 to 2 gal/100 ftZ. • EPDM Single. Ply Membranes: Apply Base Coat at a rate of 1.5 to 2 gal/100 ftZ and Finish Coat at a rate of 1.5'to 2 gal/100 ftZ. • Spray Polyurethane Foam Roof Systems: Apply Base Coat at a rate of 1.5 to 2 gaU100 ftZ'and Finish Coat at a'rate of 1.5 to 2 gal/l00 ftZ. • Concrete Decks: Apply Base Coat at a rate of 1.5 to 2 gal/100 f1Z and Finish Coat at a rate of 1.5 to 2 gal/100 ft. Container Size: 5, 55 and 275 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. NOA No.: 16-0525.09 MIAMI•DADECOUNTY Expiration Date: 08/09/21 ... , , Approval Date: 07/21/16 Page 2 of 3 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance 2. Any other documents required by the building official or the Applicable Building Code in order to properly evaluate the installation of this system. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire rating of this product. 2. Therm-0-Flex TF 1000 Series Elastomeric Roof Coating shall not be applied in inclement weather conditions. 3. The products listed herein are components of roof assemblies and are approved for use with roof assemblies that list any of the products listed herein as part of their roof assemblies Notice of Acceptance. 4. All products listed herein shall have an unannounced follow-up quality control program from an approved listing agency. Follow up test results shall be made available to Miami -Dade Product Control upon request. 5. Change in materials, use, or manufacture of any of the products listed herein shall be cause for termination of this Notice of Acceptance. 6. Therm-O-Flex TF 1000 Series Elastomeric Roof Coating shall be used as a roof maintenance coating system in accordance with applicable Building Code. Therm-0-Flex TF 1000 Series Elastomeric Roof Coating is not approved for use as a recover system. 7. Therm-O-Flex TF 1000 Series Elastomeric Roof Coating shall be applied in accordance with manufacturer's published application instructions. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 9. All approved products listed herein shallbelabeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name'or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or. the Miami -Dade County Product Control Seal as shown below . MIAMI•DADE COUNTY. M. :. . END OF THIS ACCEPTANCE NOA No.: 16-0525.09 MIAMMME COUNTY Expiration Date: 08/09/21 Approval Date: 07/21/16 Page 3 of 3