HomeMy WebLinkAboutNOAHIAM1 D
. ,�-,
SCANNED
BY
St. Lucie County
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DMSION
NOTICE OF ACCEPTANCE
LAPOLLA Industries, Inc.
15402 Vantage Parkway East
Suite 322
Houston, TX 77032
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
ww .miamidade.-ov/economv
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance_purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Spray Polyurethane Foam — Foam Lok LPA 2500, 2800, 3000 over Steel Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. ,
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 12-0605.07 and consists of pages I through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 13-0404.08
MIAMFDAOE CouNTY - Expiration Date: 06/12/18
ppp Approval Date: 06/20/13
`rFl � Qy@[rry� Page l of 6
4[t � R
ROOFING COMPONENT APPROVAL
Category:
Roofing
Sub -Category:
Spray Applied Polyurethane Roof System
Materials:
Polyurethane
Deck Type
Steel
Maximum Design Pressure-212.15 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions Test Specifications Product Description
Foam-LOK LPA 2500
2.5 lbs/ft3 density TAS 110 Polyurethane spray applied foam that utilizes
an HFC blowing agent intended for roofing
applications.
Foam-LOK LPA 2800
2.8 lbs1W density TAS 110 Polyurethane spray applied foam that utilizes
an HFC blowing agent intended for roofing
applications.
Foam-LOK LPA 3000
.3.0 lbs/ft3 density TAS 110 Polyurethane spray applied foam that utilizes
an HFC blowing agent intended for roofing
applications.
Therm-0-Flex TF 1000
N/A ASTM D6083 A premium quality, fluid applied elastomeric
Series Elastomeric Roof
roof coating.
Coating
RCS-5000 Series
N/A ASTM D6083 A premium quality, fluid applied elastomeric
Restoration Coatings
roof coating.
Therm-0-Prime
N/A A single component, water soluble acrylic
emulsion primer to prepare Galvanized Metal,
Concrete, Asphalt Substrates and Scarified
Foam for new SPF installations.
LPA 100 Foam Adhesive
N/A ASTM D 1623-09 A:Two component low rise foam
adhesive
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test Product
Product Dimensions Specifications Description Manufacturer
Any Miami -Dade
N/A As Required by Roof coating for application over Generic.
County Approved
Miami -Dade polyurethane spray.applied foam. (with current PCA)
Roof Coating
County PCA
NOA No.: 13-0404.08
MI/1MIDADE COUNTY Expiration Date: 06/12/18
Approval Date: 0620/13
Page 2 of 6
EVIDENCE SUBNIITTED:
Test Agency
Test Identifier
Test Name/Reyort
Date
PRI Construction Materials Technologies
LPII-007-02-01
TAS 110
01/27/10
LPII-008-02-01
TAS 110
01/27/10
LPII-005-02-01
TAS 110
06/12/07
PRI Asphalt Technologies
LPII- 002-02-01
ASTM D 6083/TAS 114-H
10/19/05
Underwriters Laboratories
07NK08120
UL 790
07/16/07
R14353
Fire Classification
06/26/05
Factory Mutual Research Corp.
3023796
Class 4470
10/02/05
Atlantic & Caribbean Roof
07-078
TAS 114-J
12/05/07
Consulting, LLC
08-002
TAS 114-J
02/24/08
ACRC 11-055
TAS 114-D
10/29/12
PRI Construction Materials Technologies
LPII 009-02-01
ASTM D 1623-09
03/29/11
LPII 009-02-01
ASTM D 1929-26
03/29/11
LPII 009-02-01
ASTM D 2842-06
03/29/11
LPII 009-02-01
ASTM D 1622-08
03/29/11
LPII 009-02-01
ASTM D 1621-10
03/29/11
LPII 011-02-10
ASTM C 273-00
08/01/11
Intertek
100314102 SAT-
ASTM E84
09/06/11
003 C
NOA No.: 13-0404.08
Expiration Date: 06/12/18
Approval Date: 06/20/13
Page 3 of 6
APPROVED ASSEMBLIES:
Deck Type 2: Steel
Deck Description: Minimum 22 ga. 1.5" type B G-96 Steel Deck with maximum 6' spans secured to the deck
supports with Tek 5 SD screws 6" o.c. (every rib). Side laps secured with #12 self drilling
screws at 12" o.c.
System Type A(1): Sprayed polyurethane foam covered with an Approved Miami -Dade County roof coating
applied directly onto primed steel deck.
All General and System Limitations apply.
Surface Metal surfaces should be primed with Therm-0-Prime according to LAPOLLA Industries,
Preparation: Inc. and coating manufacturers' recommendations. Primer shall be thoroughly cured prior to
application of foam.
For ferrous metal, remove loose rust and unsound primer from shop -primed iron and steel
surfaces by scraping, wire brushing or sandblasting. Prime according to LAPOLLA
Industries, Inc. and coating manufacturer's recommendations. For non-ferrous metals, clean
and prime aluminum, copper and stainless steel surfaces as recommended by LAPOLLA
Industries, Inc.
Primers shall be applied in accordance with their manufacturer's instructions. All primers
must be thoroughly dry and cured prior to foam application
Polyurethane Foam The polyurethane foam shall be applied uniformly over the entire surface at the specified
Application: thickness in compliance with the requirements set forth in o n pplicationsStandazd I2AS
JD _ The sprayed polyurethane foam shall be feathered at the edges to produce a smooth
transition.
Protective Coating Shall apply a Miami -Dade County approved roof coating with a current NOA applied in
Application: accordance with the guidelines listed in the NOA:'
Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other
materials that will impair adhesion of the protective coverings. Any damage or defects to the
polyurethane foam surface shall be repaired prior to the coating application. The coating shall
be applied the same day as the foam when possible. If more than 72 hours elapse prior to the
application of the coatings, the polyurethane foam shall be inspected for UV degradation.
Maximum Design -120 psf
Pressure:
NOA No.: 13-0404.08
Mintn•DnoecouNrr Expiration Date: 06/12/18
Approval Date: 06/20/13
Page 4 of 6
Deck Type 2I: Steel, Insulated
Deck Description: Minimum 22 GA. Type 13- 1.5" WR G90
System Type A(2): Sprayed polyurethane foam covered with an Approved Miami -Dade County roof coating
applied to .5" DensDecic adhered with Foam Adhesive directly onto a steel deck.
All General and System Limitations apply.
Surface For ferrous metal, remove loose rust and unsound primer from shop -primed iron and steel
Preparation: surfaces by scraping, wire brushing or sandblasting. Prime according to LAPOLLA
Industries, Inc. and coating manufacturer's recommendations. For non-ferrous metals, clean
and prime aluminum, copper and stainless steel surfaces as recommended by LAPOLLA
Industries, Inc..
If Required, primers shall be applied in accordance with their manufacturer's instructions. All
primers must be thoroughly dry and cured prior to foam application.
Insulation
Install %2" thick DensDecic to 22 gauge Steel deck in LAPOLLA LPA 100 Roofing adhesive
Attachment:
applied in W wide ribbons at every top flange of the deck.
Polyurethane Foam
The polyurethane foam shall be applied uniformly over the entire surface at the specified
Application:
thickness in compliance with the requirements set forth in Roofing Application Standard RAS
109. The sprayed polyurethane foam shall be feathered at the edges to produce a smooth
transition.
Protective Coating
Shall apply a Miami -Dade County approved roof coating with a current NOA applied in
Application:
accordance with the guidelines listed in the NOA.
Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other
materials that will impair adhesion of the protective coverings. Any damage or defects to the
polyurethane foam surface shall be repaired prior to the coating application. The coating shall
be applied the same day as the foam when possible., If more than 72 hours elapse prior to the
application of the coatings, the polyurethane foam. shall be inspected for UV degradation.
Maximum Design
-212.5 psf
Pressure:
NOA No.: 13-0404.08
nu�nEonoeeouNn Expiration Date: 06/12/18
Approval Date: 06/20/13
Page 5 of 6
C
TABLE 1
AMBIENT HUMIDITY APPLICATION LIMITS
SPRAYED POLYURETHANE FOAM
LAPOLLA Industries, Inc.
Air Temp/ Humidity/ Dew Point Guideline
110
100
90
80
70
60
50
40
30
Dewpoint and relative humidity forgiven dry bulb temperature.
45
67
40.5
50
70
45.5
55
72
50.5
60
75
55.5
a Airl
45
50
55
60
6.5
70
75
80
85
90
95
100
♦ Hui
67
70
72
75
78
80
78
75
70
64
58
50
f Deg
40.5
45.5
50.5
55.5
60.5
65.5
70
73.5
77
79.5
82
83
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point.
Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record
environmental conditions in the Job Log in compliance with RAS 109. Job -Log shall be maintained at the job site
and accessible to The Building Official.
3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with
LAPOLLA Industries, Inc. published literature.
4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a
composite part of the roof system and shall be compatible with the foam and coating:
S. All attachment and sizing of perimeter Bailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and the wind load requirements of applicable building code.
6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended comers and corners).
END OF TI3IS ACCEPTANCE
NOA No.: 13-0404.08
Expiration Date: 06/12/18
Approval Date: 06/20/13
Page 6 of 6
i.
7PRODUCT
MIAMI-DADE COUNTY
CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION
T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economy
Fit
LAPOLLA Industries, Inc.
15402 Vantage Parkway East, Suite 322
Houston, TX 77032
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHD may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Therm-O-Flex TF 1000 Series Elastomeric Roof Coating.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewalapplication has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety. `
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0726.04 and consists of pages 1 through 3.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 16-0525.09
Expiration Date: 08/09/21
Approval Date: 07/21/16
Page 1 of 3
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Cement -Adhesive -Coatings
Materials: Elastomeric
SCOPE:
This approves "Therm-0-Flex TF 1000 Series Elastomeric Roof Coating" as a maintenance roof
coating as manufactured by LAPOLLA Coatings, as described in this Notice of Acceptance, designed to
comply with the Florida Building Code, High Velocity Hurricanes Zone.
EVIDENCE SUBMITTED:
Test Agency
Underwriter Laboratories, Inc.
Factory Mutual Research Corp.
PRI Construction Materials
Technologies, LLC
Test Identifier
Test Name/Report
Date
R14353
UL 790
12/15/11
3023796
Class4470
10/02/05
LPII- 013-02-01
ASTM D 6083
01/10/12
TT-C-555B
MANUFACTURING LOCATION:
1. Houston, TX.
PHYSICAL PROPERTIES OF COMPONENTS
Trade names:
Therm-0-Flex TF-1001(White), TF-1002(Grey), TF-1003(Tan)
Thickness:
Wet Film per Coat: 24 mils
Dry Film per Coat: 13.2 mils
Specifications:
ASTM D 6083
Description:
A water -based eastomeric coating membrane applied at an application rate of;
• Galvanized Metal Roofs: Apply Base Coat at a rate of 1.5 to 2 gal/100 ftZ
and Finish Coat at a rate of 1.5 to 2 gal/100 A.
• SBS Modified Bitumen Granule Surfaced Membranes: Apply Base Coat at a
rate of L.5 to 2 gal/100 ftZ and Finish Coat at a rate of 1.5 to 2 gal/100 ftZ.
• EPDM Single. Ply Membranes: Apply Base Coat at a rate of 1.5 to 2 gal/100
ftZ and Finish Coat at a rate of 1.5'to 2 gal/100 ftZ.
• Spray Polyurethane Foam Roof Systems: Apply Base Coat at a rate of 1.5 to
2 gaU100 ftZ'and Finish Coat at a'rate of 1.5 to 2 gal/l00 ftZ.
• Concrete Decks: Apply Base Coat at a rate of 1.5 to 2 gal/100 f1Z and Finish
Coat at a rate of 1.5 to 2 gal/100 ft.
Container Size:
5, 55 and 275 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 16-0525.09
MIAMI•DADECOUNTY Expiration Date: 08/09/21
... , , Approval Date: 07/21/16
Page 2 of 3
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance
2. Any other documents required by the building official or the Applicable Building Code in order to
properly evaluate the installation of this system.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. Therm-0-Flex TF 1000 Series Elastomeric Roof Coating shall not be applied in inclement weather
conditions.
3. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list any of the products listed herein as part of their roof assemblies Notice of
Acceptance.
4. All products listed herein shall have an unannounced follow-up quality control program from an
approved listing agency. Follow up test results shall be made available to Miami -Dade Product
Control upon request.
5. Change in materials, use, or manufacture of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
6. Therm-O-Flex TF 1000 Series Elastomeric Roof Coating shall be used as a roof maintenance
coating system in accordance with applicable Building Code. Therm-0-Flex TF 1000 Series
Elastomeric Roof Coating is not approved for use as a recover system.
7. Therm-O-Flex TF 1000 Series Elastomeric Roof Coating shall be applied in accordance with
manufacturer's published application instructions.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
9. All approved products listed herein shallbelabeled in compliance with TAS 121 and shall bear the
imprint or identifiable marking of the manufacturer's name'or logo, city, state and the following
statement: "Miami -Dade County Product Control Approved" or. the Miami -Dade County Product
Control Seal as shown below
. MIAMI•DADE COUNTY. M. :. .
END OF THIS ACCEPTANCE
NOA No.: 16-0525.09
MIAMMME COUNTY Expiration Date: 08/09/21
Approval Date: 07/21/16
Page 3 of 3