HomeMy WebLinkAboutNOAMIAMI,
M.
SCANNED
BY
St. Lucie County
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMDVISTRATION DIVISION
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.mrarmdade.2ov/economy
Santafe Tile Corporation
8825 NW 95`b Street
Medley, FL 33178
SCOPE:
This NOA is being issued under the applicable rules and regulhtioti�ss governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to
be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
LABELING: Fach unit shall bear a permanent label with the mamsufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. 'Misule of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided do the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0210.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Caspar J Rodriguez.
NOA No.:15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
ROOFING ASSEMBLY APPROVAL
Category
Sub -Category:
Material:
Deck Type:
Roofing
Roofing Tiles
Clay
Wood
1. SCOPE
This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera
Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Anplicant Dimensions
Syecscations
Description
Santaf6 `S' Clay Roof L =18"
TAS 112 1
One piece high profile clay roof file equipped with
Tile W = 11.1"
Type I
4o nail holes. For nail -on, mortar set and adhesive
Thickness = 0.39"
Grade 1
set applications.
Trim Pieces 1= varies
TAS 112
Accessory trim, clay roof pieces for use at hips,
w = varies
rakes, ridges and valley terminations. Manufactured
varying thickness
for each tile profile.
2.1 MANUFACTURING LOCATION
1. Bogota, Colombia
2.2 SUBMITTED EVIDENCE
Test Agency
Test Identifier Test Name/Report Date
The Center for Applied Engineering, Inc.
94-156-8
TAS 101 Aug. 1994
94-156-9
TAS 102
The Center for Applied Engineering, Inc.
25-7205-1
TAS 101 March 1995
The Center for Applied Engineering, Inc.
Project: 07-07-00-91 TAS 100 Sept. 1994
(307023)
Redland Technologies
7161-03
TAS 108 Dec. 1991
Appendix U
(Nail -On)
Redland Technologies
7161-01
Static Uplift Testing Dec. 1991
Appendix III
TAS 102 & TAS 102(A)
Redland Technologies
P 0402
Withdrawal Resistance Sept. 1993
Testing of Screw vs smooth
shank nails
Redland Technologies
P 0647-01
TAS 108 Aug. 1994
(Mortar Set)
MMMi pwpe Courtrr
NOA No.:15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 2 of 5
a
2.2 SUBMITTED EVIDENCE
Test Agency
TestIdentifierTest
Name/Report
Date
Redland Technologies
P 0631-61 1
PA 108
July. 1994
(Mortar Set)
Celotex Corporation Testing Services
520305-01 thin 05
PA 102
June 1999
IBA Consultants, Inc.
2353-4
Restoring Moment
Aug. 1999
PRI Asphalt Technologies, Inc.
SFTC-003-02-01
TAS 101
12/06/02
IBA Consultants, Inc.
2353-70
TAS 101
09/22/03
IBA Consultants, Inc.
2353-71
TAS 101
09/22/03
IBA Consultants, Inc.
2353-93
ASTM C 1167
07/18/05
American Test Lab of South Florida
RT0624.01-15
ASTM C1167-03
07/01/15
3. LIMITATIONS
3.1 Fire classification is
-
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade County
Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers lublished literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard
RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
MUIMFDADECOUNTY
NOA No.:15-0915.09
-
•.. � , Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 3 of 5
Table 1: Average Weight (W) and Dimensiods (I x w )
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Width-w (ft)
Santafe'S'
6.7
1.5
0.958
Table 2: Aerodynamic Multipliers— X(ff3)
Tile
Profile
X (ft3) ,
Batten Application
A, (ft3)
Direct Deck
Santafe S;
0.274
1 0.29751116,
Table 3: Restoring Moments due to Gravity = Me (ft-lbf)
Tile
Profile
2":12"
X%12"
4":12"
I
5":12"
6":12"
I
7":12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
-irec
` r'
Battens
Direct
Deck
.5an a e'Ss�o
5.93
1 5.90 1
5.85
1 5.82
5.73
1 5.69
5.56
15!53'
5.32
5.03 1
5.00
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft- tif)`
for Nail -On Systems
Tile Profile
Fastener Type
Direct Deck
Battens
Santafe'S'
2-10d Ring Shank Nails
21.8
N/A
One #8 Screw
29.16t2
N/A
Two #8 Screws
38.281
N/A
One #8 Screw w/ Clip
51.311.2
N/A
Two #8 Screws w/ Clip
57.601
61.771
1. Approved screws as noted 'Product manufactured by others'.
2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile Profile
Tile A lication '
Minimum Attachment Resistance
Santafe'S
Tile Bond
38.91
Polyfoarn Polypro AH 160TM
28.54
2 See manufactures component approval for installation re uirements.
3 Flexible Product, Inc. Average Weight per patty 10.4 grams.
4 Polyfoam Product, Inc. Average weight per patty 9.4 grams.
Table SA: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Patty Adhesive Set Systems
—Tile-Profile
Tile Application
Minimum Attachment Resistance
San�afe;S_'
{rPol oam.Pol 1oQFfT80TM
63.8s
`-Pol` oam Poly —pro ro AH`161 "—" "
61.9s
5 Paddy placement of 63 grams of Polypro AH 160TM.
6 Paddy placement of 24 grams of Polypro AH 160T .
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar or Adhesive Set Systems
Tile Profile
Tile Application
11 Attachment Resistance
Santafe 'S'
Mortar Set
1 23.6
NOA No.: 15-0915.09
Expiration Date: 02/01/21
Approval Date: 01/21/16
Page 4 of 5
5. LABELING ,
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement:."Miami-Dade County Product Control Approved".
6.
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE
BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWING
When using one screw
Z>� use this hole.
I II
"SANTAFE S" CLAY ROOF TILE
END OF THIS ACCEPTANCE
NOA No.:15-0915.09
Expiration Date: 0210121
Approval Date: 0121116
Page 5 of 5