Loading...
HomeMy WebLinkAboutNOAMIAMI, M. SCANNED BY St. Lucie County DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMDVISTRATION DIVISION MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mrarmdade.2ov/economy Santafe Tile Corporation 8825 NW 95`b Street Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulhtioti�ss governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Fach unit shall bear a permanent label with the mamsufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. 'Misule of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided do the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0210.01 and consists of pages 1 through 5. The submitted documentation was reviewed by Caspar J Rodriguez. NOA No.:15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 ROOFING ASSEMBLY APPROVAL Category Sub -Category: Material: Deck Type: Roofing Roofing Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Anplicant Dimensions Syecscations Description Santaf6 `S' Clay Roof L =18" TAS 112 1 One piece high profile clay roof file equipped with Tile W = 11.1" Type I 4o nail holes. For nail -on, mortar set and adhesive Thickness = 0.39" Grade 1 set applications. Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at hips, w = varies rakes, ridges and valley terminations. Manufactured varying thickness for each tile profile. 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 The Center for Applied Engineering, Inc. 25-7205-1 TAS 101 March 1995 The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix U (Nail -On) Redland Technologies 7161-01 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails Redland Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) MMMi pwpe Courtrr NOA No.:15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 2 of 5 a 2.2 SUBMITTED EVIDENCE Test Agency TestIdentifierTest Name/Report Date Redland Technologies P 0631-61 1 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thin 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 IBA Consultants, Inc. 2353-71 TAS 101 09/22/03 IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05 American Test Lab of South Florida RT0624.01-15 ASTM C1167-03 07/01/15 3. LIMITATIONS 3.1 Fire classification is - 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers lublished literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations MUIMFDADECOUNTY NOA No.:15-0915.09 - •.. � , Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 3 of 5 Table 1: Average Weight (W) and Dimensiods (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe'S' 6.7 1.5 0.958 Table 2: Aerodynamic Multipliers— X(ff3) Tile Profile X (ft3) , Batten Application A, (ft3) Direct Deck Santafe S; 0.274 1 0.29751116, Table 3: Restoring Moments due to Gravity = Me (ft-lbf) Tile Profile 2":12" X%12" 4":12" I 5":12" 6":12" I 7":12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens -irec ` r' Battens Direct Deck .5an a e'Ss�o 5.93 1 5.90 1 5.85 1 5.82 5.73 1 5.69 5.56 15!53' 5.32 5.03 1 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft- tif)` for Nail -On Systems Tile Profile Fastener Type Direct Deck Battens Santafe'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.16t2 N/A Two #8 Screws 38.281 N/A One #8 Screw w/ Clip 51.311.2 N/A Two #8 Screws w/ Clip 57.601 61.771 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile A lication ' Minimum Attachment Resistance Santafe'S Tile Bond 38.91 Polyfoarn Polypro AH 160TM 28.54 2 See manufactures component approval for installation re uirements. 3 Flexible Product, Inc. Average Weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table SA: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems —Tile-Profile Tile Application Minimum Attachment Resistance San�afe;S_' {rPol oam.Pol 1oQFfT80TM 63.8s `-Pol` oam Poly —pro ro AH`161 "—" " 61.9s 5 Paddy placement of 63 grams of Polypro AH 160TM. 6 Paddy placement of 24 grams of Polypro AH 160T . Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar or Adhesive Set Systems Tile Profile Tile Application 11 Attachment Resistance Santafe 'S' Mortar Set 1 23.6 NOA No.: 15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 4 of 5 5. LABELING , 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement:."Miami-Dade County Product Control Approved". 6. SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING When using one screw Z>� use this hole. I II "SANTAFE S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.:15-0915.09 Expiration Date: 0210121 Approval Date: 0121116 Page 5 of 5