Loading...
HomeMy WebLinkAboutBUILDING SCHEMATICBUI DW'S PEAK ROOF HEIGHT vs DES/GN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F,) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EOUAL TO 60 FEET ar BASIC WIND SPEED = 170 mph RISK CATEGORY lI BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) RECEIVED MAY 2 2 7010 Permltting Department St. Lucie County PEAK ROOF I- LESS THAN 7'-9" Lee GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12 -3" Lsx GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSmVE NEGATIVE POSITIVE NEGATIVE (N ULTIMATE A.S.D. ULTIMATE A.SD. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.B.D. ULTIMATE A.S.D. 0' - 15' 7&4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.E 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 7 20'-25' 83.6 50.2 111.9 67. 1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > aD'-s0' 94.3 56.6 126.2 75.7 90.0 SAGO 1177 70.6 84.4 50.6 106.5 63.9 > 50'-60' 973 1 58.4 1 130.3 1 78.2 92.9 1 55.7 1 121.5 72.9 87.2 1 52.3 109.9 1 65.9 BUILDING'S PEAK ROOF HWgHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (P S FJ FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET k BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I- LESS THAN 12-3" L- GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE PoSH7VE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 574 175.2 105.1 88.0 52.8 155.0 93.0 s - too' 973 8.4 178.4r12O. 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 92.5 55.5 163.0 978 > 120' - 140' l03.2 61.9 189.2 95.1 57 1 167.1 100.4 > 140' - 160' 105.6 63.4 1936 97.3 58.4 171.3 102.8 > 160' - 180' 1078 64.7 197.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 101.1 50.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 105.2 63. 1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 191.' 114.7 > 300' - 350' 121.0 72.6 221.9 133. 1 196..3 1178 > 350' - 400' 123.9 74.3 227.1 136.3 a168.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8. 139.1 205. I 11 > 45D' - 500' 128.8 77.3 236. 1 141.7 208.9 12L5.3 NOTES: 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPEMNG SCHEDULE/MK£ OFF SHEET, ETC.). INDIC47ED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. r* L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. PRODUCTS WHICH BEAR A M/AMI-DADE COUNTY OR A STATE OF FLORIDA APPROVAL eE0of l 1�E�Ga� °ago='I. {y. TIL(/TGo*Al ' � ►'°0 BENS`•.?' '3vf 44167 .: J � . flOR1� ••' v? �•� SSIONA�-...•• 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS ACCORDION & BQHMIA SHUTTERS DRAWN BY RISK CAT. lI BLOCS 08109117 11 L E C O N e. WIND PRESSURE CHART DATE r TESTING & ENGINEERING COMPANY BAS/C WIND SPEED = 170 mph 17-194 W. J&& M Me. 3 NRDWM WDEM£ R J1i66 EXPOSURE D, Kd = 0.85 h..: (J05)67I-I5.T0 . Ib.: (JDS)671-15JI DRAWING N. ES-0006719 6<r. w ncscwrmr wrz 6CV. "° sacarnax 6.rz WALTER A T7U-T Jr P.E. r o1D rs-r66 /I FLORIDA Ue. IF 44167 2 , SHEET i OF 1