Loading...
HomeMy WebLinkAboutMISC LETTERArchitectonic Inc St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 May 11, 2018 RE: 4106 Mariah Circle To Whom It May Concern: SCANNED BY St. Lucie County Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2017 Florida Building Code, 170mph wind zone, exposure "B", risk category III. From Table 1609.3.1: V"rt= 170mph V11d= 132mph From Table 1609.7(I): (1) 10' x 30' (1)12'x10' From Table 1609.7(2): 20' mean roof height Required Design Pressures: -31.2 Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3 Product Pressures: +36.0 & -41.0 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1