HomeMy WebLinkAboutMISC LETTERArchitectonic Inc
St. Lucie County
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave.
Fort Pierce, FL 34982
May 11, 2018
RE: 4106 Mariah Circle
To Whom It May Concern:
SCANNED
BY
St. Lucie County
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2017 Florida Building Code, 170mph wind zone,
exposure "B", risk category III.
From Table 1609.3.1: V"rt= 170mph
V11d= 132mph
From Table 1609.7(I): (1) 10' x 30'
(1)12'x10'
From Table 1609.7(2): 20' mean roof height
Required Design Pressures: -31.2
Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3
Product Pressures: +36.0 & -41.0
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1