Web Address: www.sldd.com
Building Dept. 5LC FMO Permit #8-18.226
Project Name Sedom Townhomes Btdg 19 BLDGPermit# 1005,0364'
.Address 3134;3153 NightfallCircle City Fort Pierce
Contractor Starr weeks Associates
Address 2700 Header Canal. Road City Ft Pierce
State FL. Zip 3494.5 —� Telephone. (772)528.1130
Architect/Engineer John Foster 'Telephone (772)370-9464
Occupancy Type rApartment Construction Type VB Square Feet. 4401
Occupant Load . Number of Stories O.Access Box. Requlred Access Key.Switch 1�
AFS:Permit Required I FAPermit Required FFPPermit.
General Notes
1. An electronic: copy of the: construction documents submitted on a CD Is required. The file format, shall be .pdf only.
2. All revisions,. including the electronic copy must be received prior to permitting..
3. The Fire Marshal requires 24 hour notice on all inspections.
4. The respective. Building Department shall schedule ail final inspections through. the Fire Marshal's. Office..
S. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. Penetrations through rated assemblies shall be of the proper ULdesign. Design criteria shall besubmitted with the: construction plans.
7. Fire alarm panels shall be located indoors within air conditioned space.
S. Plans and construction are subject to corrections in the field to maintain codecomphance.
9.. Automatic fan: shutdown is required for HVAC systems that exceed:2,000 dmdesign capacity,
10. The Installation or Alteration of Fire Sprinklers; Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit.
THE FLORIDA FIRE.PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL ISEMARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
The Installation or Alteration of Fire Sprinkler, Fire Alarm, Systems require a separate review
Page 1❑ or 11 Reviewed by Tony Jerger Date 08-02-18