Loading...
HomeMy WebLinkAboutEVALUATION REPORTi SCANNED EXTERIOR RESEARCH & DESIGN, I.I.C.N jam✓ Certificate ofAuthorimtion #9503 BY \ii TRINITY ERD St. Lucie County 353 CHRISTIAN STREET, 3 OXFORD, CT T 064706478 (203)262-9245 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-1113 20 Moores Road F15444-R12 Malvern, PA 19355 Date of Issuance: 09/22/2005 (610)651-5847 Revision 13:09/05/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code "ft5"nVa`T-'u1Mffi o`$` , olume. The products described herein have been evaluated for compliance with th 6th Edition (2017) Florida Building Code ections noted herein. DESCRIPTION. CertainTeed Asphalt Roof Shingles. -�*^� LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions. of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: The facsimile seal appearing eras authorized by Robert Nieminen, P.E. on 09/05/2017. Thu does not serve as an electroniwitysigned dowment. 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specificallyfor that purpose. 1 TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition (2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Prooerty Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL(TST 1740) ASTM D3161 94NK9632 05/15/1998 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 OSNK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 05NK14836 05/22/2005 UL(TST 1740) ASTM D3161 OSNK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D7158 OSNK08037 06/28/2006 UL(TST 1740) ASTM D3161 & D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 IOCA41303 10/07/2010 UL(TST 1740) ASTM D3161 IOCA41303 10/08/2010 UL(TST 1740) ASTM D7158 IOCA41303 10/27/2010 UL(TST 1740) ASTM D3161 & D3462 10CA44960 11/11/2010 UL LLC(TST 9628) ASTM D3161, D3462 & D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161, D3462 TFWZ.R684 04/22/2014 UL LLC (TST 9628) ASTM D7158 TGAH.11684 04/22/2014 UL LLC(TST 9628) ASTM D3161 & D3462 4786334434 09/16/2014 UL LLC(TST 9628) ASTM D3161 & D3462 4786570826 02/12/2015 UL LLC(TST 9628) ASTM D3161, D3462 & D7158 4786570717 12/16/2015 UL LLC(TST 9628) ASTM D3161 & D3462 4787195678 02/09/2016 UL LLC(TST 9628) ASTM D3161, D3462 & D7158 4787380356 10/26/2016 UL LLC(TST 9628) ASTM D3462 4787380357 10/13/2016 UL LLC(TST 9628) ASTM D7158 4787380357 11/08/2016 UL LLC(TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC(TST 9628) ASTM D3161, D3462 & D7158 4787586427 01/25/2017 UL LLC (QUA 9625) Quality Control Service Confirmation Exp. 03/09/2020 Exterior Research and Design, U.C. Evaluation Report 3532.09.05-1113 CertiPcotc of Authorization#9503 6' EDITION (2017) FOC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (610) 651-5947 Revision 13: 09/05/2017 Page 2 of 12 TRINITY; ERD 4. PRODUCT DESCRIPTION: 4.1 CT2OT", XT" 25, XT" 30 and XT" 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Arcadia'", Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangleo, Landmarks", Landmark'" IR, Landmark'" Pro, Landmark'" Premium, Landmark'" TL, Landmark'" Solaris and Landmarks" Solaris IR are fiberglass reinforced, laminated asphalt roof shingles. 4.3 NorthGate'" is a fiberglass reinforced, laminated, SBS modified bitumen roof shingle. 4.4 Presidential Shaker", Presidential Shaker" IR, Presidential Shake TLT" and Presidential Solaris'" are fiberglass reinforced, architectural asphalt roof shingles. 4.5 Hatteras'", Highland Slate'" and Highland Slate"' IR are fiberglass reinforced, 4-tab asphalt roof shingles. 4.6 Patriot'" is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.7 Presidential Accessory, Accessory for Hatteras, Shangle Ridge TM, Shadow Ridge TM, Cedar Crests", Cedar Crests" IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.8 Any of the above listed shingles may be produced in AR (algae resistant) versions. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials for fire ratings of this product. 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Va:a = 150 mph (Valt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.„ 5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PLO Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, for use in wind zones up to V„d = 150 mph (Val, = 194 mph). 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (R,) for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6 (except Presidential Solarisr") exceeds the calculated uplift force (FT) at a maximum design wind speed Of Va,d = 150 mph (Vul, = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction, which shall take precedence. 5.5 All products in the roof assembly shall have quality assurance audits in accordance with F.A.C. Rule 61G20- 3. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R13 Certificate ofAuthorizaaon N9503 6'"EDITION (2017)FBC NON-HVH2 EVALUATION FL5444-R32 CertainTeed Asphalt Roof Shingles; (610) 651-SS47 Revision 13: 09/0512017 Page 3 of 12 r � xr ' TRINITY, ERD STEEP SLOPE Use six nails andfonr spots of asphalt regime cement for erely fill LANDMARK TL lanifiraterl shingle. Sec helow. Asp r t rem ing eemenl should meet ASTNI D4586 Type U. Apply I' spots of asphalt roofing cement undo 131/2 f-13" 131/2"—� each coiner and at above 12' to 13" in from each edge. (343 mm) (330 mm) (343 mm) METRI(DIMENSIONS�I"(25mm) (305 mm) ( (375. mm) 1 1305 mm) M PER M (25mm) I-�-- Figure 13-5: Use six nails andfoar spots of asput ro0fnigoement on steep slopm 1V 14-3146 12" 05 mm)—. -~~ (375 mm)-- —(305 n ( ) Nailing l units 1' 25 mm behvBaq at 1' 25 mm K nay (25 mm) I ltoofing�am"�ent Nailing areas for sleep slopes (greater than 21.12) and "Storm -Nailing" Nail between lower 2 nal Ines as shown above. 6.8.1 Hip & Ridge for Landmark•". Landmark'" IR, Landmark•" Pro, Landmark'"" Premium, Landmark'" TL, Landmark" Solarts, LandmarkTM Solaris IR. NorthGate: 6.8.1.1 Option 1: Shadow Ridge'"" or NothGate Accessory 12' 1_ 97,1' J — 6' 1 6' — (150mm) I (150mm) Centering 12 . i 7 15mm) Notches for Afignment to the Top Edge of the Pn:vbus T Cap for5'(125rmi) Exposure (19on English Dimension Shadow Ridge^' Exterior Research and Design, U.C. Certificate of Authorization N9503 6'"EDITION (2017)FBC NON-HVH2 EVALUATION CertainTeed Asphalt Roof Shingles; (610) 651-5847 (250mm) _415/1G'—415/16'- 025mm) 1 (125mm) LlheT edng1/4'/mmjAllgnmeM to 5.tthe Pmvbus7B1mm) Exposure (i m) Metric Dimension Shadow RidgeTM Evaluation Report 3532.09.05-1113 FL5444-R12 Revision 13:09/05/2017 Page 8 of 12 r 6.8.1.2 6.8.1.3 ��. TRINITY ERD 92717 4 i'Ll6' (125 rom} —+—{393 mm)—s (ktdemp Notch I rti S/Bvlt-6 m (188 mm 168mmm) ) 13 /4' (337 mm) ` Nron / Centering MIGteL'Atep 75.6' 13114' Notch 14, prNau9a4aurS¢ ( mm I (a37 nontign ) �Ai(hose 194 7� . notches to top (�mm) edge of previous rmvrse. NorthGate Ridge NorthGate Accessory 12" J �(s05mm)— ILaying Notch I � I Figure 13-7M (Ise latqngno(ebas to centersbinglis on hips and ridges, and to /oen(a Me correct arposum.. For ASTM D3161, Class F performance use BASF "Sonolastic® NPIm" adhesive or Henkel "PLO Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. Option 2: Refer to instructions herein for Cedar Crest'"', Cedar Crest'" IR hip and ridge shingles. Exterior Research and Design, I.I.C. Evaluation Report 3532.09.05-R13 Certificate of Authadratlon#9503 6t"EDrrION(2017)FBC NON-HVHZ EVALUATION FL5444-1312 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13:09/05/2017 Page 9 of 12