Loading...
HomeMy WebLinkAboutPLOT PLANSr c n � { M nO m m LT x l ADT065AE COOLER 91" HIGH FLOORLESS D1 3'-0" 3'-11" 11/8, Quote N: 18.03631 Revision: l I Project: Job 8 x 8 -SPECIFICATION- liox Meighp cooler ]'-]" (7'-3° Inferior) Insulation: 4" thick AK-KPS4 Extruded foam UL classified core flame spread 15, Smoke rating less than 165 ® Compartment l- Cooler 76"Le Dl-(1)Standard 36"xT6"leh hinged flush door with brushed hardware, interior & Exterior finish: 26 Ga. Stucco Embossed Acrylume. Heavy duty deatlbolt handle latch. Digital LED Thermometer with pilot light switch. 1807 UJ 11w, Vapor Proof, 12OV. LED fixture. 82 Lumens /watt Angled face. Requires 115yac.1 amps. (1)3/4 HP Tecumseh Indoor Condensing Unit, Model AKA94632KDXC(2T777-2), 208-230/60/1, MCA 9.2 Amps, ® BTUH 6742, Medium Temperature. Hermetic, Air-cooled, 4g1k R404A,1 year compressor and parts warranty from date of shipment within Continental USA. (1) Bohn ADT065AEWMC6K.115/60/1, low profile air defrost mairmator, 0.9 Amps with EC motor, Includes Mounted TIN, USV&Thermostat Wall Panels Interior Finish: 26 Go. Stucco Embossed Acrylume Fxterior Finish: 26 Ga. Sturm Embossed Acrylume Ce0ing Pemeb - Interior Finish: 26 Ga. Stucco Embossed Acrylume Exterior Finish: 26 Co.Stucco Embossed Acrylume Accessories Shipped Loose (5) NSF VINYL FLOOR SCREED R" Date: 03/01/2018 Customer Approval: NN1--l' SGP � Gou��y Quote #: 18-03631 Revision: 1 Job #:180647 Customer:JCC Restaurant Supplies NYC INC 7'-10 1 /8" Kill KII) n n C1 C2 COOLER 91" HIGH FLOORLESS 11 1a "35718 N6 �� ��� D1 N5 3'-0" 3'-11 " 11 1 /8' Project: Job 8 x 8 Cooler Date: 03/01/2018 Page 1 of 4Version: 2.00.0200 Ref Pty Part# Width HeighHeighl Int Ext Di 1 DA470086FJ 47" 86 3/4" A Z6YL ACRYL 26 N1 1 NG470086F 47" 86 3/4" A zR6YL ACRYL 26 N2 1 ND470086F 47" 86 3/4" A ZR6YL ACRYL 26 N3 2 NB37CO86F 37 3/8" 86 3/4" AC2R6YL ACRYL 26 ' N4 2 NA470086F 47" 86 3/4" A RI. ACRYL 26 N5 1 NC110086F 11" 86 3/4" A zR6YL ACRYL 26 N6 1 ND35GO86F 35 7/8" 86 3/4" ACR26YL ACRYL 26 C1 1 CC4700940 47" 94" ACZR6YL ACRYL 26 C2 1 CD4700940 47" 94" ACRYL ACRYL 26 Ell At ON& taking cool fuller` Int T-10 1 /8" 0 ti t ti tte #: 18-03631 Revision: 1 #:180647 Restaurant Supplies NYC INC 3of4 I_ 3'-0" 03/01/2018 2.00.0200 ilt®®I� taking cool tuMer` D1 Quote #: 18-03631 Revision: 1 Job #:180647 Customer:JCC Restaurant Supplies NYC INC (3) 1FM SCREM j'8:4}/9' � u wun u+c ax .�w FlxOxE9 fLWF (z) t/a' z i i/Y Pw-rnIa sucQVE suuxt cnsxn on �x soEs (� mnMs) 20018: INTERIOR FLUSH DOOR JAMB ALUMINUM ANGLE.1 1/2- X 1 1/2- X 5 1/4- TO SECURE TO CONCRETE FLOOR QUANTITY 2 REQUIRED Project: Job 8 x 8 Cooler Page 4 of 4 INTERIOR OE WALK—IN WALL PANEL TEK SCREWS #BX3/4- 20' ON CENTERS FINISHED FLOOR VINYL SCREED NSF 4 PIN —GRIP 0 20` O.C. SILICONE SEALANT (BY OTHERS) INTERIOR AND EXTERIOR VINYL CREED WALL PANEL 8823: NSF VINYL FLOOR SCREED 72" Date: Version: 2.00.0200 talang cool Further-