Loading...
HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com June 20, 2018 Re: Riley Shutter Installation 9900 S. Ocean Dr. (#606) Jensen Beach, FL 34957 To Whom It May Concern: 6GPweD St• uuBe GOOrti JUN 222018 ST. LucieCounty, Permitting Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code, 2017 for the installation of accordion shutters at the above referenced address. Wind speed: V,dt:;165 mph, Vazd: 128 mph Exposure: D FILE C ®rY Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter. Location: Covered Porch (See Attached Sketch) j RequiredDesign Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the installation instructions and Florida Product Approval and F - Accordion Shutters ;shall be FL# 389.1. Thank you for your attention to this matter. Submitted by: PAUL WELCH INC. tulWelch P.E. Reg. No 29945 design pressures as listed Building Code 2017.