HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
June 20, 2018
Re: Riley Shutter Installation
9900 S. Ocean Dr. (#606)
Jensen Beach, FL 34957
To Whom It May Concern:
6GPweD
St• uuBe GOOrti
JUN 222018
ST. LucieCounty, Permitting
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code, 2017 for the installation of accordion shutters at the above
referenced address.
Wind speed: V,dt:;165 mph, Vazd: 128 mph
Exposure: D FILE C ®rY
Enclosure Type: Enclosed
Shutter Size: 96" Maximum Height
Shutter. Location: Covered Porch (See Attached Sketch) j
RequiredDesign Pressure: +51.3 / -68.7 PSF
Shutters to be installed shall be equal to, or exceed the
above "Required Design Pressure".
Accordion Shutters shall be installed in accordance with the
installation instructions and Florida Product Approval and F
- Accordion Shutters ;shall be FL# 389.1.
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH INC.
tulWelch P.E.
Reg. No 29945
design pressures as listed
Building Code 2017.