HomeMy WebLinkAboutFLOOR PLANSITE SPECIFIC FLJOR PLAN:
SCALE: N.T.S.
7380 SE OCEAN DRIVE
BUILDING FOOTPRINT
PLAN VIEW
O
O O
72.0' MIN. BUILDING DIM.
N ��
UNIT
#318
SCANNED
BY
St. Lucie County
UNIT #318
N30 FT ABOVE GRADE
FLOOR PLAN AND UNIT LAYOUT
O
DESIGN NOTES: n I lIll pNNKLB
FLORIDA BUILDING CODE SIXTH EDITION (2017) ASCE 7-10 ���\ C1?,VON
M
Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE 'D', ENCLOSED ST�Ri1C�OltE; L ,
RISK CATEGORY=II, Kd=0.85, Kzt=1.0, Kz=TABLE 30.3-1, GCpi=+/-0.18
qh = 0.00256*Kz*Kzt*Kd*V*V � * 7)Jop
P = qh ((GCp)-(GCpi)) a t
MRH=90', ZONE(S) AS NOTED, ROOF TYPE'MONOSLOPE', ROOF SLOPE 0.0° `
PRESSURES: NOTED BELOW — O pPE 12328
INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS ='TI VAI ID PT,
GENERAL NOTES:
1. THIS ENGINEERED PLAN IS INTENDED TO PROVIDE SITE -SPECIFIC DESIGN PRESSURES FOR THE R D =-
STRUCTUREFORTHE PURPOSE OF THE INSTALLATION OF GLAZED/NON-GLAZED PRODUCTS AS PROP65 D r
PROVIDED BY OTHERS. NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IS OFFERED AS TO THE Alnp
OR APPLICABILITY OF ANY PROPOSED SYSTEM OR COMPONENT USED ALONG WITH THESE PRESSURES UNL )) I I
PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN.
2. NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS REQUIREMENTS. ALL
EGRESS ISSUES ARE TO BE ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL.
3. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS
WORK REPLACES THE EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISTING HOST STRUCTURE,
THIS ENGINEER SHALL BE NOTIFIED BEFORE CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO
RE -INSPECT AND RE-EVALUATE DESIGN. NO WARRANTY, EITHER EXPRESSED OR IMPLIED, IS CONTAINED HEREIN.
SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL VERIFY
DURING CONSTRUCTION THAT THE SUBSTRATE IS OF THE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE
WITH THE INTENT OF THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF
THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE
OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS.
4. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO
THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN.
S. ANY ]UNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT
COMPLYING WITH AAMA 800 AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION
AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS
OUTSIDE THE SCOPE OF THIS CERTIFICATION.
6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT
ELECTROLYSIS.
7. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND
SHALL BE MINIMUM 1.5X THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR
EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND
NON -REACTIVE.
B. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND
2.5xDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE.
9. ALL FASTENERS TO BE #12 X 3/4' OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR
CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH ALL APPLICABLE
FEDERAL,STATE, AND LOCAL CODES.
10. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY
SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN.
CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION.
11. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS
SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST &
DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM
ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL
CODES & FROM DEVIATIONS OF THIS PLAN.
12. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON
CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE
OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD
VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY
TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF
EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
* ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR
CERTIFICATION
DESIGN INFORMATION:
MPPI(
QIY
WiX(In.)
PRODUCT
PROWCf NOOEL
APPROVAL
PPES�RE
MUWON
NUWONSIZE
P8H
P➢PROVPLA
AFPRwALA
1
(1
1U.COz41.005.52
&�9021
533
I7i11.06
SERIES HRJIO ALUMINUM HOWMNIAL ROILING WINDOW
N51-J5
N/A
N/A
2
1)
35.00 x O.W
.33
1J-0630.08
SERIES SH-JOO AWMINUM SINGLE HUNG WINDOW
1801A0
17 530.01
1 X 4 x 0. In
3
(1)
35.WX4J.D]
3
1J-0630.08
SERIES SH-700 ALUMINUM SINGLE HUNG WINDOW
�80140
0-0630.01
1 x 4 x 0. In
4
1
35.00 x4J.DJ
17-0630.08
SERIES SH-700 AWMINUM SINGLE HUNG WINDOW
'w l/ o
WA
N/A
DRAWING NOTES:
LIVE Rom, yj
r i
Now-
P.E.
®nw
SHALL REMAIN IN
IAT, & PRINTED
IF THERE IS NO
,TORE ON SHEET 1
- DOES NOT
U 10 N
O
Z"IT 0
® WM_yx
F' M g N O N
W 1•, LLUI X.W YC
Z � III Lu o u XD rD
rn>U._.=Xa
U gQ W gw U' 0
0 co cZ2
WW mVD�wwu
w
O' wUI O@,Z
3LL�,8
N W 6iw
ow w
10p
U
.Z.
(Il J m
J > m
z 3 rn > LL
0 =
V) .w.U-o <o U
F o Z w
IL Q N W m
N H N w O w
,U o N � Do In
N
In M ... O pm "
Um
F-
I-
WlM LEVEL OF ALTERATION I ONLY. IF LEVEL OF ALTERATION IS DIFFERENT, THIS
[STING BALCONIES WRH EXISTING 42' HIGH APPROVED GUARDS WHICH SWILL NOT
18-6252
SCALE: NTS UNLESS N
'
NCHES. OPERABLE WINDOWS WITH SILL HEIGHTS LOWERTHAN 42 INCHES THAT DO
LL BE EQUIPPED WRH A PERMANENT BLOCKER WHICH PROHIBITS THE WINDOW FROM
BELOW 3W(E)(CEPT FOR RESCUE WINDOWS WHICH IN THE EVENT OF AN EM ERGENCY
1RAnON SHALL ALSO HAVE SEPARATE CERTIFICATION CONFORMING TO FBC FOR
�CILJIII
PRODUCTS HAVE BEEN CALCULATED USING WIDTH - HEIGHT 13 (EFFECTIVE AREA = H'H/3)