HomeMy WebLinkAboutMISC8 050 3AL 50 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
STANDBY POWER RATING
50 kW, 63 kVA, 60 Hz
PRIME POWER RATING'
45 kW, 56 kVA, 60 Hz
)A Q
*Built in the USA using nomesuc and foreign parts
*EPA Certified Prime ratings are not available in the U.S. or Its Territories.
**Certain options or customization may not hold certification valid.
SCANNED
BY
St. Lucie County
GE, _ :RAC° I INDUSTRIAL
POWER
II i
�lm
eo
1.0101
,
- - 06o
CODES AND STANDARDS
Generac products are designed to the following standards:
AUI. us
�%
NFPJC
UL2200, UL508, UL142, UL498
Image used for illustration purposes only
For over 50 years, Generac has led the industry with
innovative design and superior manufacturing.
Generac ensures superior quality by designing and
manufacturing most of its generator components, including
NFPA70, 99, 110, 37
alternators, enclosures and base tanks, control systems and
communications software.
NEC700,701,702,708
Generac's gensets utilize awidevarietyof options,
configurations and arrangements, allowing usto meet the
IS09001, 8528, 3046, 7637,
standby power needs of practically every application.
Pluses #2b, 4
Generac searched globally to ensure the most reliable
enginespower our generators. We choose only enginesthat
J;Wji3= NEMA ICS10, MG1, bTA&MIIINTY have already been proven in heavy-duty industrial application
PLAN REVIEW un der adverse conditions.
�ASLL m> nmm* rntaa ANSI C62.41
BLDG:
DATE:
ELE9
DATE"
DATE
PLUMB:
DATE
MECK
DATE
Generac is committed to ensuring ourcustomers'service
support continues after their generator purchase.
I L 1 �
t
S0050 3.4L 50 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
STANDARD FEATURES
ENGINE SYSTEM
General
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel flexible exhaust connection
• Critical Exhaust Silencer (enclosed only)
• Factory Filled Oil
• Radiator Duct Adapter (open set only)
Fuel System
• Fuel Icckoff solenoid
• Primary fuel filter
Cooling System
• Closed Coolant Recovery System
• UV/Ozone resistant hoses
• Factory -Installed Radiator
• Radiator Drain Extension
• 50/50 Ethylene glycol antifreeze
• 120 VAC Coolant Heater
Engine Electrical System
• Battery charging alternator
• Battery cables
• Battery tray
• Solenoid activated starter motor
• Rubber -booted engine electrical
connections
CONTROL SYSTEM
Control Panel
• Digital H Control Panel - Dual 4x20 Display
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable PLC
• RS-232/485
• All -Phase Sensing DVR
• Full System Status
• Utility Monitoring
• Low Fuel Pressure Indication
• 2-Wire Start Compatible
• Power Output (kW)
ALTERNATOR SYSTEM
• UL2200 GENprotectn
• 12leads (3-phase, non 600 V)
• Class H insulation material
• Vented rotor
• 213 pitch
• Skewed stator
• Auxiliary voltage regulator power winding
• Amortisseur winding
• Bmshless Excitation
• Sealed Bearings
• Automated manufacturing (winding, insertion,
lacing, varnishing)
• Rotor dynamically spin balanced
• Full load capacity alternator
• Protective thermal switch
GE , _ ERAC' I INDUSTRIAL
POWER
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of circuits - highAow voltage
• Separation of circuits - multiple breakers
• Silencer Heat Shield
• Wrapped Exhaust Piping
• Silencer housed in discharge hood (enclosed only)
• Standard Factory Testing
• 2 Year Limited Warranty (Standby rated Units)
• 1 Year Limited Warranty (Prime rated Units)
• Silencer mounted in the discharge hood (enclosed only)
• Power Factor
• kW Hours, Total & Last Run
• ReaVReactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
• Date/Time Fault History (Event Log)
• IsochronousGovernor Control
• Waterproof/sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto/Off/Manual Switch
• E-Stop (Red Mushroom -Type)
• NFPA11 o Level I and II (Programmable)
• Customizable Alarms, Warnings, and
Events
• Modbus protocol
• Predictive Maintenance algorithm
• Sealed Boards
• Password parameter adjustment
protection
ENCLOSURE (IF SELECTED)
• Rust -proof fasteners with nylon washers to
protect finish
• High performance sound -absorbing material
• Gasketed doors
• Stamped air-intake louvers
• Air discharge hoods for radiator -upward pointing
• Stainless steel lift off door hinges
• Stainless steel lockable handles
• Rhino Coat'"- Textured polyester powder coat
TANKS (IF SELECTED)
• UL 142
• Double wall
• Vents
• Sloped top
• Sloped bottom
• Factory pressure tested (2 psi)
• Rupture basin alarm
• Fuel level
• Check valve in supply and return lines
• Rhino Coat °- Textured polyester powder coat
• Stainless hardware
• Single paint ground
• 15 channel data logging
• 0.2 msec high speed data logging
• Alarm information automatically comes up
on the display
Alarms
• Oil Pressure (Pre -programmable Low
Pressure Shutdown)
• Coolant Temperature (Pre-programmed
High Temp Shutdown)
• Coolant Level (Pre-programmed Low Level
Shutdown)
• Low Fuel Pressure Alarm
• Engine Speed (Pre-programmed Over
speed Shutdown)
• Battery Voltage Warning
• Alarms & warnings time and date stamped
• Alarms & warnings for transient and steady
state conditions
• Snap shots of key operation parameters
during alarms & warnings
• Alarms and warnings spelled out (no alarm
codes)
S0050 3A 50 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
CONFIGURABLE OPTIONS
ENGINE SYSTEM
General
O Oil Heater
0 Industrial Exhaust Silencer
Fuel System
O Flexible fuel lines
O Primary fuel filter
Engine Electrical System
O 1OA UL battery charger
0 2.5A UL battery charger
O Battery Warmer
ALTERNATOR SYSTEM
O Alternator Upsizing
O Anti -Condensation Heater
O Tropical coating
O Permanent Magnet Excitation
ENGINEERED OPTIONS
ENGINE SYSTEM
O Coolant heater ball valves
0 Block Heaters
O Fluid containment pans
ALTERNATOR SYSTEM
O 3rd Breaker Systems
CONTROL SYSTEM
0 Spare inputs (x4) / outputs (x4) - H Panel Only
O Battery Disconnect Switch
RATING DEFINITIONS
CIRCUIT BREAKER OPTIONS
0 Main Line Circuit Breaker
O 2nd Main Line Circuit Breaker
O Shunt Trip and Auxiliary Contact
O Electronic Trip Breaker
GENERATOR SET
0 Gen -Link Communications Software
(English Only)
O 8 Position Load Center
O 2 Year Extended Warranty
0 5 Year Warranty
0 5 Year Extended Warranty
ENCLOSURE
0 Weather Protected
O Level 1 Sound Attenuation
O Level 2 Sound Attenuation
0 Steel Enclosure
O Aluminum Enclosure
O 150 MPH Wind Kit
O 12 VDC Enclosure Lighting Kit
0 120 VAC Enclosure Lighting Kh
0 AC/DC Enclosure Lighting Kit
0 Door Alarm Switch
GENERATOR SET
0 Special Testing
0 IBC Seismic Certification
ENCLOSURE
O Motorized Dampers
O Door switched for intrusion alert
O Enclosure ambient heaters
GEI,` ,,-':RAC' I INDUSTRIAL
- POWER
Standby - Applicable for a varying emergency load for the duration of a utility power outage with no overload capability.
TANKS (Size on last page)
0 Electrical Fuel Level
O Mechanical Fuel Level
0 54 Gal (204.4 L) Usable Capacity
0 132 Gal (499.7 L) Usable Capacity
O 211 Gal (798.7 L) Usable Capacity
0 300 Gal (1135.6 L) Usable Capacity
O 8" Fill Extension
O 13' Fill Extension
0 19" Fill Extension
CONTROL SYSTEM
O 21-Light Remote Annunciator
O Remote Relay Panel (8 or 16)
0 Oil Temperature Sender with Indication
Alarm
O Remote E-Stop (Break Glass -Type,
Surface Mount)
O Remote E-Stop (Red Mushroom -Type,
Surface Mount)
0 Remote E-Stop (Red Mushroom -Type,
Flush Mount)
O Remote Communication - Modem
0 Remote Communication - Ethernet
0 10A Run Relay
O Ground Fault Indication and Protection
Functions
TANKS
O Overfill Protection Valve
O UL2085 Tank
O ULC S-601 Tank
O Stainless Steel Tank
O Special Fuel Tanks (MIDEQ and
FL DEP/DERM, etc.)
O Vent Extensions
Prime - Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of
every 12 hours. The Prime Power option is only available on International applications. Power ratings in accordance with ISO 8528-1, Second Edition
Sb050 3A 50 kW GEL _fERAC' IN13USTRIAL
INDUSTRIAL DIESEL GENERATOR SET —�— POWER
EPA Certified Stationary Emergency
APPLICATION AND ENGINEERING DATA
ENGINE
General
Make
Generac
EPA Emissions Compliance
Stationary Emergency
EPA Emissions Reference
See Emissions Data Sheet
Cylinder #
4
Type
In -Line
Displacement- L (cu In)
3.4 (207.48)
Bore - mm (in)
98 (3.86)
Stroke - mm (in)
113 (4.45)
Compression Ratio
18.5:1
Intake Air Method
Turbocharged/Aftercooled
Cylinder Head Type
Cast Iran OHV
Piston Type
Aluminium
Crankshaft Type
Forged Steel
Engine Governing
Governor Electronic Isochronous
Frequency Regulation (Steady State) +/- 0.25°%
Lubrication System
Cooling System
Cooling System Type Closed Recovery
Water Pump Pre-Lubed, Self Sealing
Fan Type Pusher
Fan Speed (rpm) NA
Fan Diameter mm (in) 560 (22)
Coolant Heater Wattage 1500
Coolant Heater Standard Voltage 120 V/240 V
Fuel System
Ultra Low Sulfur Diesel Fuel
Fuel Specifications
ASTM
Fuel Rltedng (microns)
10
Fuel Injection
Bosch (VE)
Fuel Pump Type
Engine Driven Gear
Injector Type
Pintel - 2100 PSI
Fuel Supply Line mm (in)
7.92 (0.312)
Fuel Return Line mm (in)
7.92 (0.312)
Oil Pump Type Gear
Oil Filter Type Full Flow Cartridge Engine Electrical System
Crankcase Capacity - L (qts) 7(7.4) System Voltage 12 VDC
Battery Charging Alternator 20 A
Battery Size See Battery Index
0161970SBY
Battery Voltage 12 VDC
Ground Polarity Negative
ALTERNATOR SPECIFICATIONS
Standard Model 390
Pales 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distodion <3%
Telephone Interference Factor (TIF) <50
Standard Excitation
Synchronous
Bearings
Single Sealed Cartridge
Coupling
Direct, Flexible Disc
Load Capacity - Standby
100%
Prototype Short Circuit Test
Yes
Voltage Regulator Type
Digital
Number of Sensed Phases
All
Regulation Accuracy (Steady State)
�0.25%
S6050 13AL 150 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
OPERATING DATA
POWER RATINGS
GEI - °RAC' I INDUSTRIAL
--�� POWER
Single -Phase 120/240
VAC @1.Opf
50 kW
Standby
Amps:
208
Three -Phase 1201208
VAC @0.8pf
50 kW
Amps:
173
Three -Phase 120/240
VAC @0.8pf
50 kW
Amps:
150
Three -Phase 2771480
VAC @0.8pf
50 kW
Amps:
75
Three -Phase 346/600
VAC @0.8pf
50 kW
Amps:
60 -
STARTING CAPABILITIES (SKVA)
480 VAC
kW 10% 15% 20% 25°% 30%
SKVA vs. Voltage Dip
VAC
10°% 15% 20% 25% 30% 35%
Standard 50 34 52 69 86 103 120 1 26 39 52 65 77 90
Upsize 1 60 42 63 83 104 125 146 1 32 47 62 78 94 110
FUEL CONSUMPTION RATES*
dQrIIIIh
Diesel - gph (]ph)
Fuel Pump Lift - ft (m) Percent Load gph ([ph)
3 (1) 25% 1.3 (4.92)
50°% 2.3 (8.71)
Total Fuel Pump Flow (Combustion + Return) 75% 3.3 (12.50)
5.5 gph 100% 4.3 (16.36)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
Coolant Flow per Minute
gpm (Ipm)
Standby
12.2 (46)
Coolant System Capacity
gal (L)
2.5 (9.5)
Heat Rejection to Coolant
BTU/hr
135,900
Inlet Air
cfm (m3/hr)
7500 (212)
Max. Operating Radiator Air Temp
F° (CO)
122 (50)
Max. Ambient Temperature (before Berate)
Fe (C°)
104 (40)
Maximum Radiator Backpressure
in H20
0.5
COMBUSTION AIR REQUIREMENTS
ENGINE
Standby
Flow at Rated Power cfm (m3/min) 166 (4.7)
EXHAUST
Standby
Standby
Rated Engine Speed rpm 1800
Exhaust Flow (Rated Output) cfm (ms/min)
448 (12.7)
Horsepower at Rated kW** hp 86
Max. Backpressure (Post Silencer) inHg (Kpa)
1.5 (5.1)
Piston Speed ft/min (rrVmin) 1335
Exhaust Temp (Rated Output) °F rC)
1044 (562)
BMEP psi 169
Exhaust Outlet Size (Open Set) mm (in)
63.5 (2.5)
Refer to -Emissions Data Sheer formulmum bHP for EPA and SCAOMo permitting purposes.
Deration — Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please consult a Generac Power Systems Industrial Dealer for additional details. All
performance ratings in accordance with IS03046, BS5514, IS08528
and DIN6271 standards.
i
SD050 3A 50 kW
INDUSTRIAL DIESEL GENERATOR SET
EPA Certified Stationary Emergency
DIMENSIONS AND WEIGHTS*
L
L
L
GLivERAC' I INDUSTRIAL.
�I� ��POWER
OPEN SET
RUNTIME
USABLE
HOURS
CAPACITY
L x W x Hin(mm)
WT Ies(kg) - Tank B Open Set
GAL (L)
H NO TANK
-
76 (1930.4) x 38 (914.4) x 45 (1143)
1756 (796)
13
54 (204.4)
76 (1930.4) x 38 (914.4) x 58 (1473.2)
2236 (1014)
31
RW-
132 (499.7)
76 (1930.4) x 38 (914.4) x 70 (1778)
2466 (1119)
49
211 (798.7)
76 (1930.4) x 38 (914.4) x 82 (2082.8)
2675 (1213)
70
300 (1135.6)
93 (2362.2) x 38 (914.4) x 86 (2184.4)
2738 (1242)
STANDARD ENCLOSURE
RUNTIME USABLE WT Ies(kg)-Enclosure Only
HOURS CAPACITY LxWx H in(mm)
GALL) Steel Aluminum
NLW
H NO TANK - 95 (2413) x 38 (965.2) x 50 (1270)
13 54(204.4) 95 (2413) x 38 (965.2) x 63 (1600.2)
31 132(499.7) 95 (2413) x 38 (965.2) x 75 (1905) 334(152)
49 211 (798.7) 95 (2413) x 38 (965.2) x 87 (2209.8)
115(52)
70 300 (1135.6) 95 (2413) x 38 (965.2) x 91 (2311.4)
LEVEL 1 ACOUSTIC ENCLOSURE
RUNTIME USBLE CAPACITY LxWxHin (mm) WT its(kg)- Enclosure Only
HOURS GAL L) Steel Aluminum
-
NO TANK - 113 (2870.2) x 38 (965.2) x 50 (1270)
150 (68)
H 13 54 (204.4) 113 (2870.2) x 38 (965.2) x 63 (1600.2)
P
31 132 (499.7) 113 (2870.2) x 38 (965.2) x 75 (1905) 435 (198)
49 211 (798.7) 113 (2870.2) x 38 (965.2) x 87 (2209.8)
70 300 (1135.6) 113 (2870.2) x 38 (965.2) x 91 (2311.4)
W
LEVEL 2 ACOUSTIC ENCLOSURE
RUNTIME USABLE WT lbs(kg)- Enclosure Only
HOURS CAPACITY L x W x H in(mm)
GALL) Steel Aluminum
NO TANK - 95 (2413) x 38(965.2) x 62(1574.8)
13 54 (204.4) 95 (2413) x 38 (965.2) x 75 (1905)
H 31 132 (499.7) 95 (2413) x 38 (965.2) x 87 (2209.8) 520 (236) 179 (81)
49 211 (798.7) 95 (2413) x 38 (965.2) x 99 (2514.6)
70 300 (1135.6) 95 (2413) x 38 (965.2) x 103 (26162)
'All measurements are approximate anti for estimation purposes only. Sound d8A can be found on the sound
W data sheet. Enclosure Only weight Is added to Tank & open Set weight to delermine total weight.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without nestles. Dimensions and weights are for preliminary purposes only. Please consull a Genemc Power Systems Industrial Dealer for detailed installation drawings.
Generac Power Systems, Inc. I P.O. Box 8 1 Waukesha, WI 53187 Part No OK5096
P: (262) 54441811 O 2015 Generate Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Rev. C 06/08/15