RE: 3267 Industrial 27 Street
To Whom It May Concern:
SCANNED
S( Cr,C e Count
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2017 Florida Building Code,160 mph wind zone,
exposure "C", risk category II.
From Table 1609.3.1: Vwt= 160mph
V.d= 124mph
From Table 1609.7(1): 16'h x 20'w door, 160mph=+23.3/-26.0
From Table 1609.7(2): 30' mean roof height, Exposure C = 1.40
Required Design Pressures: 23.3 x 1.40 = 32.62
-26 x 1.40 = -36.4
Product: Janus International Corporation, Series3100 26 ga. Door Assembly
Product Pressures: +36.0 & -41.0
806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 42" FL Reg #AA26003348 1 of 1
Architectonic 'inc
St. Lucie County
Planning & Development Services
Building and Code Regulation Division
June 6, 2018
RE: 3207 Industrial 27 Street
To Whom It May Concern:
SCANNED
BY
St. Lucie County
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2017 Florida Building Code,160 mph wind zone,
exposure "C", risk category II.
From Table 1609.3.1: Vmc= 160mph
V,,d= 124mph
From Table 1609.7(1): 16'h x 20'w door, 160mph=+23.3/-26.0
From Table 1609.7(2): 30' mean roof height, Exposure C = 1.40
Required Design Pressures: 23.3 x 1.40 = 32,62
-26 x 1.40 = -36.4
Product: Janus International Corporation, Series 310D 26 ga. Door Assembly
Product Pressures:, +36.0 & -41.0
FILE Copy
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1