Loading...
HomeMy WebLinkAboutPLANSSCANNED St. Luce ClOuntV ff Sprint SITE INFORMATION TOWER OWNER: CROWN CASTLE 4511 N HIMES AVE SUITE 210 TAMPA, FL 33614 PROPERTY OWNER JOSEPH H. & ELEANOR HALE 24 MARSH CREEK ROAD FERNANDIA, FL 32034 APPLICANT: SPRINT 6391 SPRINT PARKWAY OVERLAND PARK, KS 65251-2650 LATITUDE: 27' 29' 0.OV' N 27.48328' LONGITUDE: 80' 34' 1.30" W -80.567' COUNTY: ST. LUCIE ZONING JURISDICTION: PROJECT: SITE BU #: SITE CASCADE: PARCEL NUMBER SITE ADDRESS: SITE TYPE: DO MACRO DEPLOYMENT 813700 M113XC160 123111100030005 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 SELF SUPPORT TOWER AREA MAP PROJECT DESCRIPTION .14r. 1) THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY. �\ \\ 2) THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND WILL NOT PRODUCE ANY SEWAGE. •.�, 3) THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING WIRELESS INSTALLATION: a' A. INSTALLATION OF (1) NEW COMMSCOPE ANTENNA I i A B. INSTALLATION OF (1) NEW RFS ANTENNA !j C. INSTALLATION OF (2) NEW CCI ANTENNAS SITE LOCATION �' D. INSTALLATION OF (1) NEW RRUS-11 RADIOS E. INSTALLATION OF (1) NEW RRUS-31 B25 RADIOS nwn&-✓psR F. INSTALLATION OF (3) NEW RRUS-82 RADIOS G. INSTALLATION OF (1) NEW HYBRID CABLE H. INSTALLATION OF (1) NEW ANTENNA SECTOR MOUNT I. INSTALLATION OF MOUNT MODIFICATIONS VICINITY MAP ST. LUCIE COUNTY � --, ' '• CROWN PROJECT MANAGER: RODGER GARDNER (904) 647-7698 _ L x �� o ,ISDE LOCATION IF�J� mau.. APPLICABLE CODES ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALL IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. - FLORIDA BUILDING CODE 6TH EDITION (2017) ANSI/EIA/TIA-222-G (ALLOWED PER EXEMPTION y5 OF 1609.1.1) ASCE 7-10 Wit = 152 MPH (ULTIMATE 3 SECOND GUST) Vasd = 118 MPH (NOMINAL 3 SECOND GUST) RISK CATEGORY = II EXPOSURE = C IMPORTANCE FACTOR= 1.0 - NATIONAL ELECTRICAL CODE, 2014 EDITION (NFPA 70-2014) - FLORIDA FIRE PREVENTION CODE 6TH EDITION - CONTRACTOR TO CONFIRM THAT THE SITE IS COMPLIANT WITH RF WARNING SIGNAGE & EMERGENCY SIGNAGE AS REQUIRED BY THE FEDERAL GUIDELINES CONTAINED WITH GET 65 BULLETIN & AS PER SPRINT GUIDEUNES. ALTERNATE CALL NUMBER:a� " 1-80OA324770 ULL)NOtIt G4 BEFtlIEYW W0 AN�401 gN T HICK BEE, FRONT Sias Gti� S� REAR ZNG. LIST OF DRAWINGS SITE GENERAL ARRANGEMENT PLANS T-1 TITLE SHEET T-2 GENERAL NOTES T-3 I GENERAL NOTES ARCHITECTURAL / CIVIL PLANS C-1 OVERALL SITE LAYOUT A-1 SITE ELEVATION A-2 ANTENNA LAYOUTS & DETAILS A-3 DETAILS A-4 DETAILS A-5 COLOR CODING A-6 DETAIL SHEET GROUNDING PLANS - G-1 I GROUNDING DETAILS Sprint® 6391 SPRINT PARKWAY OVERLAND PARK, KS I66251 CCCROWN CASTLE 4511 N. HIVES AVENUE, SUITE 210 TAMPA, FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY TAMP: by'slb6bibopg P. - ®moo®� '`• No 72513 ;� o • m eQn'� MARC MAIER, PE FL PROFESSIONAL ENGINEER LIC. $ 72513 DRAWN BY: BMF APPROVED BY: MM DATE D 1OS/09/18 USA FNG. JOB NO. 12180002-09 TITLE SHEET T-1 GENERAL NOTS 1. ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN SPRINT OR IT'S DESIGNATED REPRESENTATIVE. 2. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS AT TESTING RETHAT HE DOES HAVE SU FFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENEN SED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 3. UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 4. ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERCEDE ANY CONFUCTING NOTES ENCLOSED HEREIN. 5. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 6. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE TESTING AGENCY PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS. METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. 7. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH. THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH _SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN - CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. 9. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCAL BUILDING CODE. 10. ALL PROPOSED CELLULAR EQUIPMENT AND FIXTURES SHALL BE FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED OTHERWISE HEREIN. 11. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS, WITH THE RESIDENT LEASING AGENT FOR APPROVAL 12. PREFABRICATED BUILDING INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. STRUCTURAL STPL'I NOTES: 1. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE A.I.S.C. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE A.I.S.C. CODE OF STANDARD PRACTICE. 2. STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A26. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. ALL STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A50D GRADE B. ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBUES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. 3. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) D.1.1/D1.1M:2010. STRUCTURAL WELDING CODE -STEEL WELD ELECTRODES SHALL BE E70XX. 4. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL 5. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 6. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST A.I.S.C. SPECIFICATIONS. 7. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEELFABRICATOR IN ACCORDANCE WITH A.I.S.C. I SPECIFICATIONS. 8. HOT -DIP- GALVANIZE ITEMS SPEC IFIED TO BE ZINC COATED. AFTER FABRICATION WHERE PRACTICAL GALVANIZING: ASTM A 123, ASTM, A 153/A 153M OR ASTM A 653/A 653M, G90, AS APPLICABLE. 9. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A 780 OR BY APPLICATION OF STICK OR THICK PASTE MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED, AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALUCS. IN STICK OR PASTE, SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL 10. CONTRACTOR SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS/SPECIFICATIONS IF NO INFORMATION IS CONTAINED IN THESE PLANS OR IF THE MANUFACTURER'S SPECIFICATIONS ARE STRICTER. NOTE: REFER TO SPRINT SPECIFICATIONS AS THE CONTROLLING STANDARD FOR PROPOSED CONSTRUCTION. PERMIT& 1, CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FOR THIS PROJECT FROM ALL APPLICABLE GOVERNMENTAL AGENCIES. 2. ANY PERMITS WHICH MUST BE OBTAINED SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 3. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND THE ACI 318-08, "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE% 4. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE JURISDICTIONAL STATE COUNTY OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. 5. ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL HAVE A SET OF APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM 36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTMCON A325.ECTIO FASTENERS SHALL BE 5/8' MIN. TH BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL 2. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL 3. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. 4. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. 5. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. 6. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8' RADIUS. 7. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS, USE A TWO -BOLT HOLE NEPA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL. B. FOR ALL EXTERNAL GROUND CONNECTIONS. CLAMPS AND CADWELDS, APPLY A USERAL PROTECTIVE COATING OR AN ANTI -OXIDE COMPOUND SUCH AS 'NO -OXIDE A' BY DEARBORN CHEMICAL COMPANY. 9. REPAIR ALL METAL SURFACES THAT HAVE BEEN CUT OR DAMAGED BY REMOVING ANY EXISTING RUST AND APPLYING COLD GALVANIZATION. 10. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS. CABLE LENGTHS LISTED ARE APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION. DUE TO FIELD CONDITIONS, ACTUAL CABLE LENGTHS VARY. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. SPRINT CONSTRUCTION SPECIFICATIONS MINI MACRO CELL SITES BASIC WORK a. MEET ALL REQUIREMENTS OF JURISDICTIONS I b. IF EQUIPMENT FURNISHED BY COMPANY DOES NOT MATCH THE EQUIPMENT LISTED ON THE RFDS AND SHOWN ON THE PERMITTING DRAWINGS, RESOLVE DISCREPANCY THROUGH INSTALLER'S CONSTRUCTION MANAGER AND COMPANY'S POINT OF CONTACT. C. CABLE INSTALLATIONS 1. ALL CABLES MUST BE OUTDOOR RATED AND HAVE UV RESISTANT OUTER JACKETS. 2. CABLE BENDS MUST NOT EXCEED MANUFACTURERS ALLOWABLE CABLE BEND RADII. 3. AT RADIOS INSTALL SERVICE LOOPS FOR POWER, FIBER AND ETHERNET SECURED AT LEAST TWICE 1 THE STRUCTURE. 4. SPARE FIBERS MUST BEE ENCASED D I LOW PROFILE NNECT RIGHT ASSEMBLY. 5. FIBERS MUST A FIELD -TERMINATED WITH ITS LC -TYPE CONNECTORS 6. CONDUITS G EARTH; PROVIDE PVC. CONDUITS EXPOSED AND IN FACILITIES; PROVIDE RGS HAND DIG TRENCHES IN COMPOUNDS. 7. SECURE AND SUPPORT CONDUITS AND CABLES ON NO MORE THAN 48 INCH INTERVALS. 8. ON TOWER SITES RGS CONDUITS MAY BE SURFACE MOUNTED AWAY FROM WALK WAYS AND ACCESS/EGRESS PATHS. IF INSTALLATIONS IN WALKWAYS ANDACCESS/EGRESS PATHS CAN NOT BE AVOIDED, IDENTIFY THE CONDUIT ENVELOPE/TRIP HAZARD BY ALTERNATING YELLOW AND BLACK STRIPES PAINTED ON CONCRETE AND CONDUIT. SERINT-FURNISFIRD EQUIPMENT a. INSTALL THE FOLLOWING EQUIPMENT AT LOCATIONS AND AZIMUTHS SHOWN ON THE TESTING AND CONSTRUCTION COMPLETE a. SWEEP ALL COAXIAL CABLES ACCORDING TO SPRINT STANDARD TS-0200 b. PANEL ANTENNA AUGNMENT- USING .ELECTRONIC AUL ALIGNMENT TOO 1AZIMUTH/DOWNTILT +/- 1 DEGREE. C. LEAVE EQUIPMENT DE -ENERGIZED UNTIL INSTRUCTED BY THE COMMISSIONING AND INTEGRATION TEAM T0 ENERGIZE d. OTHER REQUIREMENTS AND DELIVERABLES MAY BE REQUIRED BEFORE THE CONSTRUCTION COMPLETE MILESTONE CAN BE ACTUALIZED IN SITERRA (SPRINTS'S DATABASE -OF -RECORD) CONSTRUCTION DRAWINGS. 1. MICROWAVE EQUIPMENT CABINET 2. MICROWAVE DISH 3. PANEL ANTENNAS py 4. RADIOS 5. GPS ANTENNAS _ 6. FILTERS y 7. 120 VOLT DIN -RAIL CIRCUIT BREAKER ASSEMBLY FFFiliii c TONER INSTALLATIONS a. MEET ALL REQUIREMENTS OF THE TOWER OWNER. b. INSTALL CORRUGATED FLEXIBLE CONDUIT UP THE TOWER TO COMPANIES BAD CENTER. c. PROVIDE HANGING GRIPS OR CONDUIT CLAMPS AND INSURE CONDUITS AS WELL AS INNER CABLES ARE SUPPORTED. d. CONDUIT RISERS: TOP OF TOWER TURN CONDUIT DOWN AND PROVIDE CABLE TERMINATION FITTINGS. EXTEND CABLES TO RADIOS EXPOSED AND SECURED TO STRUCTURE, AT CONDUIT EXIT FROM TOWER PROVIDE DRIP LOOPS AND WEEP HOLES. e. AT ICE BRIDGE RUN CABLES IN RGS CONDUIT. UTILIZE CONDULETS TO MAKE COMPACT 90 DEGREE TURNS. AC POWER TIE-IN a. INSTALL SPRINT'S 120 VOLT DIN -RAIL CIRCUIT BREAKER ASSEMBLY IN THE EXISTING POWER PROTECTION CABINET TELCO SECTION. b. INSTALL A 20 AMP MOLDED CASE CIRCUIT BREAKER IN AVAILABLE SPACE IN THE ADJACENT PPC POWER SECTION LOAD CENTER (IF REQUIRED). GROUNDING a. 120 VOLT CIRCUITS; POWER CABLES MUST BE 3-WIRE WITH EQUIPMENT GROUNDING CONDUCTOR. b. SUPPLEMENTAL GROUNDING; ALL GROUNDING HARDWARE MUST BE UL STAMPED AS SUITABLE FOR GROUNDING HARDWARE. c. RADIOS; BOND RADIO TO THE TOWER TOP OR SECTOR GROUND BAR WITH #8 BARE TINNED COPPER WIRE (GREEN INSULATED ON ROOFTOPS). d. DIN -RAIL CIRCUIT BREAKER ASSEMBLY; BOND SURGE ARRESTOR TO PPC TELCO BOARD GROUND BAR. MANOR MATERIALS a. CONDUIT. b. RIGID GALVANIZED STEEL CONDUIT (RGS): UL LISTED. COMPUANT WITH ANSI STANDARD CEO, HOT -DIP GALVANIZED,WITH THREADED FITTINGS, MANUFACTURERS: ALLIED. REPUBLIC, WHEATLAND, OR EQUAL. c. CORRUGATED FLEXIBLE CONDUIT; DURALINE OR EQUAL d. UQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LFMC): UL LABELED, UV RESISTANT, FLAME RETARDANT PVC JACKET, HOT -DIP GALVANIZED. GREY. MANUFACTURERS; AFC. ANACONDA. SOUTHWIRE OR EQUAL e. PVC CONDUIT: SCHEDULE 40. CARLON OR EQUAL (. CABINET HUBS AND CABLE TERMINATION FITTINGS: OZ GEDNEY OR ROXTEC g. COAXIAL CABLE JUMPERS: 1/2' LDF-4. MANUFACTURERS: COMMSCOPE. RFS OR FCT. h. FASTENERS AND HARDWARE I. TO SECURE RACEWAYS. UTILIZE NON CORRODING NON-MAGNETIC METALLIC FASTENERS AND HARDWARE SUITABLE FOR THE PURPOSE. ). POWER CABLES - 3/C a SOOW BY SOUTHWIRE OR EQUAL k. ETHERNET CABLES AND CONNECTORS: OUTDOOR RATED, CAT 5E, BELDEN OR EQUAL. I. FIBER CABLES: CORNING FREEDOM FAN OUT' OUTDOOR RISER CABLE. 4F, SINGLE MODE OR EQUAL m. RF TRANSPARENT PAINT FOR ANTENNA CONCEALMENT: SELECT NO/LOW CARBON PAINTS, W NO/LOW TITANIUM DIOXIDE. AND WITHOUT SUSPENDED METAL PATICALES (ALUMINUM, ZINC, COPPER, ETC.) COI OR OR_ CODING: a. COLOR CODE CABLES AND CONDUITS AS REQUIRED BY SPRINT STANDARD TS-0200 PREPARED FOR: • Sprint*111011 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 CCCROWN CASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA, FL 33614 ®IENGINEERING 2813 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XCI60 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY STAMP: ~ e® l3eA ♦i �aRiykk ®0+��a°�.�.'•t:•A�S: �'�i moo a •.{� �µ : P1a 72553 ° Z IE OF •�W ® F•• C9 e MARC MAIER, PE FL PROFESSIONAL ENGINEER DC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: 05/09/18 USA ENG. JOB NO: 12180002-09 REVISION NO DESCRIPTION BY DATE A PREUMINARY CD'S REV *A' BMF 05/09 18 0 REV 0 CDs ISSUED BMF 05/16/18 SHEET TITLE: GENERAL NOTES SHEET NUMBER: T-2 GENERAL NOTES: j i i 1. OBTAIN PERMITS AND PAY FEES RELATED TO ELECTRICAL WORK PERFORMED ON THIS PROJECT. DELIVER COPIES OF ALL PERMITS TO CLIENT REPRESENTATIVE. 2. SCHEDULE AND ATTEND INSPECTIONS RELATED TO ELECTRICAL WORK REQUIRED BY JURISDICTION HAVING AUTHORITY. CORRECT AND PAY FOR ANY WORK REQUIRED TO PASS ANY FAILED INSPECTION. 3. ENGAGE AN INDEPENDENT ELECTRICAL TESTING FIRM APPROVED BY CLIENT TO TEST AND VERIFY THAT IMPEDANCE DOES NOT EXCEED 5 OHMS TO GROUND. THE COMPLETED SITE SHALL BE TESTED AND A REPORT SENT TO CLIENT REPRESENTATIVE. 4. REDUNED AS -GUILTS ARE TO BE DELIVERED TO CLIENT REPRESENTATIVE. 5. PROVIDE TWO COPIES OF OPERATION AND MAINTENANCE MANUALS IN THREE-RING BINDER. 6. FURNISH AND INSTALL THE COMPLETE ELECTRICAL SERVICE, CABLE TRAY, TELCO CONDUIT AND GROUNDING SYSTEMS. 7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND LOCAL ORDINANCES, INSTALLED IN A NEAT MANNER, AND SHALL BE SUBJECT TO APPROVAL BY CLIENT REPRESENTATIVE. 8. CONDUCT A PRE -CONSTRUCTION SITE VISIT AND VERIFY EXISTING SITE CONDITIONS AFFECTING THIS WORK. REPORT ANY OMISSIONS OR DISCREPANCIES FOR CLARIFICATION PRIOR TO THE START OF CONSTRUCTION. 9. PROTECT ADJACENT STRUCTURES AND FINISHES FROM DAMAGE. REPAIR TO ORIGINAL CONDITION ANY DAMAGED AREA. 10. REMOVE DEBRIS ON A DAILY BASIS. DEBRIS NOT REMOVED IN A TIMELY FASHION WILL BE REMOVED BY OTHERS AND THE RESPONSIBLE SUBCONTRACTOR SHALL BE CHARGED ACCORDINGLY. REMOVAL OF DEBRIS SHALL BE COORDINATED WITH THE CLIENT'S REPRESENTATIVE. DEBRIS SHALL BE REMOVED FROM THE PROPERTY AND DISPOSED OF LEGALLY. USE OF THE PROPERTY'S DUMPSTER IS PROHIBITED. 11. ALL CONSTRUCTION SHALL BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. - 12. SIGNAL WIRING SHALL BE INSULATED #18 AWG. NO BX OR ROMEX CABLE IS PERMITTED. 13. WIRING DEVICES AND"EQUIPMENT SHALL BE UL LISTED AND SPECIFICATION GRADE. 14. FUSES ARE NOT ALLOWED: CIRCUIT BREAKERS ONLY. 15. MATERIALS SHALL BE NEW AND CONFORM TO THE APPUCABLE STANDARDS ESTABLISHED FOR EACH ITEM BY THE ORGANIZATIONS LISTED BELOW: - AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) - UNDERWRITER'S LABORATORY (UL) - NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION (NEMA) - AMERICAN STANDARDS ASSOCIATION (ASA) - NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 16. DESIGN AND INSTALLATION OF MATERIALS SHALL COMPLY WITH REGULATIONS OF: - THE NATIONAL ELECTRICAL CODE (NFPA 70) - THE NATIONAL ELECTRICAL SAFETY CODE (ANSI C-2) - THE LIFE SAFETY CODE (NFPA 101) - LIQUEFIED PETROLEUM GAS (NFPA 54 AND 58) - LOCAL CODES, 17. ALL CONDUIT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NFPA 70), LATEST EDITION. ELECTRICAL SPECIFICATION NOTES GROUNDING NOTES: I I 1. PROVIDE GROUNDING AND BONDING IN ACCORDANCE WITH CLIENT GROUNDING & BONDING PRACTICE UNLESS DIRECTED OTHERWISE BY DRAWINGS, NATIONAL ELECTRICAL CODE, OR AUTHORITIES HAVING JURISDICTION. THE ABOVE REFERENCED SPECIFICATIONS IS AN INTEGRAL PART OF THE DESIGN DOCUMENTS AN MUST BE STRICTLY ADHERED TO. WHERE CONFLICTS BETWEEN THIS SPECIFICATION. CODES, AND AUTHORITIES HAVING JURISDICTION ARISE, THE MOST STRINGENT SHALL GOVERN. 2. BUSS CONNECTORS SHALL BE 2-HOLE LONG BARREL TYPE COMPRESSION LUGS. 3. LUGS SHALL BE ATTACHED TO BUSSES USING BOLTS, NUTS AND DRAGON TOOTH WASHERS. NO WASHERS ARE ALLOWED BETWEEN THE ITEMS BEING GROUNDED. 4. SURFACE CONNECTIONS SHALL BE MADE TO BARE METAL PAINTED SURFACES SHALL BE FILED TO ENSURE PROPER CONTACT. APPLY NON -OXIDIZING AGENT TO CONNECTIONS. 5. COPPER BUSSES SHALL BE CLEANED, POLISHED, AND A NON -OXIDIZING AGENT APPLIED. NO FINGERPRINTS OR DISCOLORED COPPER WILL BE PERMITTED. 6. GROUND CONDUCTOR RUNS SHALL BE STRAIGHT AS POSSIBLE, 12" FOR #2 AND LARGER CONDUCTORS. 7. HARDWARE (I.E., NUTS BOLTS, WASHERS. ETC.) IS TO BE STAINLESS STEEL. S. GROUND CABLES AT POINTS SHOWN ON GROUNDING RISER DIAGRAM WITH MANUFACTURER'S GROUNDING KITS. 9. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE (CADWELD) TO GROUND RING AND GROUND RODS. REMAINING GROUNDING CONNECTIONS SHALL BE MECHANICAL CONNECTIONS. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO -HOLE LUGS. 10. GROUND RING. COMPRISED OF #2 BARE TINNED SOLID RADIAL COPPER CONDUCTOR, SHALL HAVE A MINIMUM DISTANCE OF 24" FROM THE STRUCTURE AND BE BURIED A MINIMUM OF 30" BELOW GRADE. 11. CADWELD GROUND RODS TO GROUND RING. RODS TO BE 5/e" X 8'-0" COPPER CLAD STEEL WITH COPPER JACKET OF NOT LESS THAN 0.01 INCHES THICK. THE TOP OF GROUND ROD -SHALL EXTEND NO MORE THAN 6 INCHES ABOVE THE BOTTOM OF THE TRENCH. 12. INTERCONNECT OUTDOOR EQUIPMENT GROUND RING AND TOWER " GROUND RING WITH EXOTHERMIC WELD. - 13. INSTALL GROUND RODS ON GROUND RING AT 16' INTERVALS. INSTALL GROUND RODS TO FENCE POSTS AT 16' INTERVALS. 14. ALL ELECTRICAL GROUNDING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) AND THE LATEST EDITION OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 780, APPROVED BY LOCAL AUTHORITY. 15. ALL GROUNDING CONNECTIONS SHALL BE COATED WITH AN ANTI -CORROSIVE AGENT SUCH AS "T & B KOPR SHIELD", NO-OXY', NOALOX' OR PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. 16. GROUND WIRES SHALL BE #2 BARE TINNED SOLID COPPER FROM CONDUCTOR FOR BONDING CONNECTIONS UNLESS OTHERWISE NOTED ON PLANS. . 17. DOCUMENT GROUND RING INSTALLATION AND CONNECTIONS WITH PHOTOGRAPHS PRIOR TO BACKFILUNG SITE. PRESENT PHOTO ARCHIVE AT SITE "PUNCH LIST" WALK TO CLIENT REPRESENTATIVE. 18. THE ENTIRE SYSTEM SHALL BE GROUNDED USING LOCKNUTS AND BONDING NUTS ON CONDUITS AND PROPERLY BONDED GROUND CONDUCTORS. RECEPTACLES AND EQUIPMENT BRANCH CIRCUITS SHALL BE GROUNDED WITH A FULL-SIZED EQUIPMENT GROUNDING CONDUCTOR RUN IN THE CIRCUIT'S CONDUIT. 19. CONTRACTOR SHALL INSPECT AND TEST ANY NEW AT&T GROUNDING SYSTEM WITH A BIDDLE-MEGGER TESTER UTILIZING THE FALL OF POTENTIAL'METHOD AND CONTACT CONSTRUCTION MANAGER IF RESISTANCIE EXCEEDS 5 OHMS AND SHALL FIELD MODIFY GROUNDING SYSTEM AS NECESSARY TO ACHIEVE COMPLIANCE. TEST RESULTS AND CONCLUSIONS SHALL BE RECORDED FOR PROJECT CLOSE-OUT DOCUMENTATION. 20. ALL UNDERGROUND GROUND WIRE TO BE BURIED 30' DEEP. 21. ALL BURIED GROUND CONNECTIONS WILL BE MADE USING THE EXOTHERMIC WELD PROCESS. 22. ALL GROUND WIRES SHALL BE CONNECTED TO THE CIGDE USING TWO -HOLE CRIMP/COMPRESSION CONNECTORS. 23. AN APPROVED ANTI OXIDATION COMPOUND SHALL BE USED ON ALL EXTERNAL CONNECTIONS, EXCLUDING EXOTHERMIC WELDS, AND ON ALL EXTERNAL GROUND BARS. COAT ALL CONDUCTORS AND SURFACES PRIOR TO CONNECTION. 24. REFER TO SHELTER MANUFACTURER AND CLIENT SPECS FOR INTERNAL GROUNDING DETAILS. 25. GROUND CONDUCTOR RUNS SHALL BE STRAIGHT AS POSSIBLE, WITH 12- FOR #2 AND LARGER CONDUCTORS. 26. ALL POSTS TO BE BONDED UNDERGROUND VIA AN EXOTHERMIC WELD. PVC MIN. 6" INTO GROUND. 27. IF GROUNDED METALUC OBJECTS ARE LESS THAN 6' FROM A FENCE POST, THEN THE POST SHOULD BE GROUNDED TO THE GROUND RING. 28. ALL GROUND WIRES THAT ARE ROUTED ABOVE GROUND SHOULD BE INSTALLED IN 12" OF 3/4"4 PVC ALL THE WAY TO THE WELD/BOND WITH 6" BELOW GRADE. 29. BOND THE SHELTER FOUNDATION REBAR TO THE SHELTER GROUND RING USING EITHER AN EXOTHERMIC WELD, A PREFABRICATED WELDED REBAR ASSEMBLY, UL APPROVED 2 BOLT PARALLEL CONNECTOR OR WIRE TIES. APPLY HEAT SHRINK OR ELECTRICAL INSULATING TAPE AROUND THE CONDUCTOR AS NECESSARY. 30. BOND ANY MISC. METAL OBJECTS TO GROUND RING VERIFY WITH CONSTRUCTION MANAGER 31. ALL ABOVE GROUND GROUND WIRES SHALL BE INSIDE FLEX CONDUIT AND SEALED WITH SILICONE. " 32. IF TOWER IS GREATER THAN 200THEN CONTRACTOR IS TO INSTALL A GROUND BAR AT THE CENTER OF THE TOWER. ELECTRICAL NOTES: 1. FOR EQUIPMENT SHELTER INTERNAL WIRING, REFER TO .CONCRETE SHELTER SHOP DRAWINGS. 2. ALL ELECTRICAL CONNECTIONS IN DISCONNECTS, METERS AND AC PANELS NEED "NO-OXY", "NOALOX" OR "PENETROX" APPLIED. VERIFY PRODUCT WITH PROJECT MANAGER. PREPARED FOR: Sprint. l 00 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 CROWN CCCASTLE 4511 N. HIMES AVENUE, SURE 210 TAMPA, FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY STAMP: lloullP. r� 8a�G P• 0 ®o �e��CEtds�..;9e�s. N!O 725119 )-• sra MAY 1 ��a�Zb`1E8 MARL MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: 05/09/18 USA ENG. JOB NO: 12180002-09 REVISION NO DESCRIPTION BY DATE A PREl1MINARY CO'S REV "A' BMF OS 09/18 0 REV 0 CDs ISSUED BMF 05/16 18 J SHEET TITLE: GENERAL NOTES SHEET NUMBER: T-3 ABBREVIATIONS AFF ABOVE FINISHED FLOOR AGL ABOVE GRADE LEVEL AMSL ABOVE MEAN SEA LEVEL APPROX APPROXIMATE AWG AMERICAN WIRE GAUGE BLDG BUILDING BTS BASE TRANSMISSION STATION �yT ✓; CLR CLEAR 91 COL COLUMN CONC CONCRETE CND CONDUIT DWG DRAWING FT FOOT (FEET) EGB EQUIPMENT GROUND BAR ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING ELEV ELEVATION EQUIP EQUIPMENT (E) EXISTING EXT EXTERIOR FND FOUNDATION F FIBER GA GAUGE GALV GALVANIZED GPS GLOBAL POSITIONING SYSTEM GND GROUND LTE LONG TERM EVOLUTION MAX MAXIMUM MFR MANUFACTURER MOB MASTER GROUND BAR MIN MINIMUM N.T.S. NOT TO SCALE O.C. ON CENTER OE/OT OVERHEAD ELECTRIC/TELCO PPC POWER PROTECTION CABINET RBS RADIO BASED STATION RRU REMOTE RADIO UNIT RGS RIGID GALVANIZED STEEL IN INCH(ES) INT INTERIOR LB(S) or # POUND(S) SF SQUARE FOOT STL STEEL TYP TYPICAL UE/UT UNDERGROUND ELECTRIC/TELCO UNO UNLESS NOTED OTHERWISE VIF VERIFY IN FIELD W/ WITH XFMR TRANSFORMER - SYMBOLS ® REVISION WORK POINT rc)� UTILITY POLE ® BRICK COMPRESSED STONE CONCRETE EARTH GRAVEL ® MASONRY ® STEEL _ CENTERLINE --- PROPERTY LINE _ — - - — LEASE LINE ---------- EASEMENT LINE ——* —� — CHAIN LINK FENCE 0= r— WOOD FENCE —UGP— UNDERGROUND POWER —UGT— UNDERGROUND TELEPHONE —OE/OT— OVERHEAD ELECTRIC/TELEPHONE e —UGF— UNDERGROUND FIBER e I N —r x— x— x— x— x— x— x— x— 1 UTILITY POLE x c VVV _ a x 6"x4'-O" PARKING CURB x (TYP) rFENCE 5'-0"x5'-O" PAD (TYP) 10'-0"x13'-0" PAD W/ STEPS & HANDRAILS AT&T MOBILITY 11'-9"-36'-2" BUILDING —XI —x —x —x —x —x —x —x CONTRACTOR TO INSTALL NEW EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. NOTE: CONTRACTOR SHALL RESTORE AND REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. x— x— x— x— x— x— x— x— x— x— INSTALL PROPOSED SPRINT (1) HYBRID #8 AWG CABLES WITH EXISTING (2) HYBRID #8 AWG CABLES RUN ALONG EXISTING WAVEGUIDE BRIDGE (ABANDONED) CROWN CASTLE/ SPRINT PCS 12'-0"x28'-O" BUILDING LEG A 250'-0" SS TOWER / //I 'AD O"x2AREIA/ AT&T MOBILITY rMETER CROWN 5 -0 z11 -0 GEN PAD IN A 101-0"x15'-0 AREA x—x x—x 22'-6" 1 4'-6" .� OVERALL SITE PLAN SCALE: 1" = 10'-0" (BASED ON 11x17 PAPER SIZE) T-TpOBJLE„ 5'-0 x9 -0 GEN PAD/AREA WORKING JTY FRAME x— x— x— x— xF . SPRINT PCS L; i PAD IN A 15'-O"x22' 7" .-_. AREA.. :-H .. 6.-0"4 FND PIER (TYP) (ABANDONED) METRO PCS i 8'-0"x16'-O" PAD x m I UTILITY N FRAME (TYP) x o I 0 2'-O" �\ x (ABANDONED) AT&T MOBILITY 10'-0"x20'-O" BUILDING IN A 12'-O"x28'-O" AREA —x —x —x —x —x —x —x —R —x 28'-0" gw-�n _Nwl v CALL FLORIDA 811 ONE CALL -DIAL 811 CALL 3 NARKING DAYS BEFORE YOU DIG 1-8WE38 097 PREPARED FOR: Sprint ' 10.000 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 CROWN CCCASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA. FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY STAMP: a -� No 72513 y : ST -2: OF S O-N ... ��0�>``e MAY NPIP0115%l' MARC MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: 05/09/18 USA END. J09 NO: 12180002-09 REVISION NO DESCRIPTION BY I DATE A I PREUMINARY CD'S REV W BMF 05/09 18 0 REV 0 CDs ISSUED BMF 05/16 18 SHEET TITLE: OVERALL SITE PLAN SHEET NUMBER: C-1 EXISTING 250'-0" SELF SUPPORT .� TOWER ELEVATION SCALE: N.T.S. TOP OF TOWER ELEV.= 250 -0 AGL CE OF EXISTING METRO PCS MOUNT h ELEV. = 237'-0" AGL CE OF EXISTING CROWN CASTLE MOUNT ELEV. = 225'-0 AGL CE OF EXISTING T-MOBILE MOUNT ELEV. = 217'-O AGL Of PROPOSED SPRINT ANTENNAS ELEV. = 210'-0" AGL CE OF E%ISTING AT&T MOUNT ELEV. = 195'-0" AGL CE OF EXISTING CROWN CASTLE MOUNT ELEV. = 178'-0" AGL CE OF EXISTING AT&T MOUNT h ELET = 162-0" AGL OF EXISTING SPMDISH ELEV. = 12RINTW AGL CE OF EXISTING T-MOBILE MOUNT ELEV. = 120'-0" AGL PROPOSED SPRINT (1) HYBRID #8 AWG CABLES & EXISTING (2) HYBRID #8 AWG CABLES ROUTED UP TOWER PER APPROVED STRUCTURAL ANALYSIS EXISTING SPRINT WAVEGIUDE BRIDGE EXISTING SPRINT EQUIP �� � LE C ON A CONCRETE PAD ANTENNA MOUNTING NOTES: 1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS ; SHALL CONFORM TO CURRENT ANSI "STRUCTURAL APPENDIX B FOR WIND LOADING; "STRUCTURAL \printvo STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA J SUPPORTING STRUCTURES" OR APPLICABLE LOCAL CODES. 2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER 6391 SPRINT PARKWAY FAPRICATION IN ACCORDANCE WITH ASTM A123 "ZINC j OVERLAND PARK, KS 66251 j (HOT -DIPPED GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS OTHERWISE NOTED. RE 3. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE CROWN SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM "ZINC -COATING (HOT DIP) ON IRON AND STEEL CASTLE HARDWARE", UNLESS OTHERWISE NOTED. \/ 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY 4511 N. HIMES AVENUE, COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. SUITE 210 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE TAMPA, FL 33614 NUTS AND SHALL BE INSTALLED SNUG TIGHT. 6. MINIMUM HORIZONTAL SPACING SHALL BE 2'-0" BETWEEN ALL ANTENNAS. 1. CONTRACTOR TO FIELD VERIFY ANTENNA CABLE LENGTHS. ®IENGINEERING 2. ALL MAIN CABLES WILL BE COLOR CODED AT THREE (3) LOCATIONS. 2818 CYPRESS RIDGE BOULEVARD 3. COLOR CODE ALL ANTENNA AND COAX WITH 2" WIDE SUITE 110 BANDS OF COLORED TAPE WITH 1" SEPARATION BETWEEN WESLEY CHAPEL, FL 33544 BANDS. (813) 994-0365 4. COLOR CODE ALL TOP AND BOTTOM GROUND KITS WITH FL COA #31705 1" WIDE BANDS OF COLORED TAPE WITH 1/2" SITE NAME: SEPARATION BETWEEN BANDS.5. BANDS2"NG START COLOR W DE 2NEXT MINUTE MAID DEACONNECTOR 6. START SECTOR TO 7. ALL MAIN CABLES WILL BE GROUNDED W/ COAXIAL SHE NUMBER: CABLE GROUND KITS AT: • THE ANTENNA LEVEL M113XCI60 • MID LEVEL IF TOWER IS OVER 200' • BASE OF TOWER PRIOR TO TURNING HORIZONTAL SITE ADDRESS: • TERMINATION OF COAX LINES TO JUMPERS S. ALL NEW GROUND BAR DOWNLEADS ARE TO BE 2651 MINUTE MAID ROAD CADWELDED TO THE EXISTING ADJACENT GROUND BAR FORT PIERCE, FL 34945 DOWNLEADS A MINIMUM DISTANCE OF 4FT BELOW ST. LUCIE COUNTY GROUND BAR 9. PROVIDE BUSS BAR NEAR RBS FOR ATTACHMENT OF STAMP:�gid4BB�Bf$ P COAX GROUND KITS .qb� a,'�c ^.C•••\+�GciV S+l�•°•' ��d® 11. AELL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM ties • THE TRUE NORTH HEADING. NO 72513 f 2. CONTRACTOR SHALL VERIFY PROPOSED ANTENNA RAD %�' ; e CEDER AND ORIENTATIONS WITH SPRINT WIRELESS PRIOR TO INSTALLATION OF ANTENNAS. m 3. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL STATE n- ° �0 ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING ANALYSIS` Y THE PROPOSED LOADS. REFER TO STRUCTURAL BY OTHERS. N'� °o •' O Fl®!•°°`• \_�® 4. CONTRACTOR SHALL REFER TO TOWER or CALCULATIONSFOR ADDITIONALOADS.NOE ERECTION OR BO �00@N,I Q11� MODIFICATION OFTOWER SHALL BE WITHOUT 8``�`, MAY �018 APPROVAL OF STRUCTURAL ENGINEER. I�, MARC MAIER• PE FL PROFESSIONAL ENGINEER UC. # 72513 COAXIAL ANTENNA CABLE NOTES: 1. THE ANTENNA COAXIAL CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING SPRINT DRAWN BY: BMF WITH 3 TYPEWRITTEN SWEEP TESTS. (ANTENNA RETURN APPROVED BY: MM LOSS TEST). THIS TEST SHALL BE PERFORMED TO THE DATE DRAWN: 05/09/13 SPECIFICATIONS AND PARAMETERS OUTLINED BY THE SPRINT RADIO FREQUENCY (RF) ENGINEER. THIS TEST USA ENG. JOB NO: 12180002-09 SHALL BE PERFORMED PRIOR TO FINAL ACCEPTANCE OF REVISION THE SITE. 2. THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE NO DESCRIPTION BY DATE RESPONSIBLE FOR PERFORMING AND SUPPLYING SPRINT A PREUMINARY CD'S REV "A" BMF 05/09/1E WITH 3 TYPEWRITTEN TIME DOMAIN REFLECTOMETER (TOR) 0 REV 0 CDs ISSUED BMF OS 16 1E TESTS TO VERIFY CABLE LENGTH AND TO CHECK FOR WATER DAMAGE. 3. VAPOR WRAP WILL BE USED TO SEAL ALL CONNECTIONS. 4. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE WILL BE 1/2" JUMPERS AND SHALL NOT EXCEED 6'-0". MAXIMUM LENGTH FOR THE JUMPERS AT RBS UNITS WILL BE 6'-0". 5.IF COAX IS BEING RE -USED FOR THIS INSTALLATION, PRE AND POST ANTENNA LINE SWEEPS ARE REQUIRED. 6. UPON COMPLETION, PROVIDE A HEIGHT VERIFICATION DEPICTING BAD CENTER AND TOP OF ANTENNA. SHEET TITLE: TOWER ELEVATION CONTRACTOR NOTES: 1. ALL EXISTING COMA EQUIPMENT TO BE SHEET NUMBER: REMOVED PRIOR TO 2.5 Ghz CONSTRUCTION. A w NEW SPRINT EQUIPMENT (1) RRUS-11 & (1) RRUS-82 MOUNTED ON BACK TO BACK RRU MOUNT EXISTING ICK TIOBACK EQUIPMENT (1) RRMOUNT&RRUS-31 B25 MOUNTED ON BA POWER AND FIBER CABLE NEW SPRINT EXISTING TOWER PANEL ANTENNA 7 — I I ANTENNA MOUNT NEW SPRINT BREAKOUT UNIT )f RF JUMPERS ANTENNA, RRU AND BREAK-OUT MOUNTING DETAILS SCALE:N.T.S. VOTE: NO WORK SHALL COMMENCE WITHOUT THE APPROVED BUILDING/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. IF REQUIRED, THE CONTRACTOR SHALL MODIFY BUILDING AND/OR ANTENNA MOUMS AS INDICATED IN THE ABOVE MENTIONED STRUCTURAL REPORT OR ASSOCIATED MODIFICATION DESIGN DRAWINGS. INSTALL PROPOSED RRUS-82 ON PROPOSED BACK TO BACK RRU MOUNT INSTALL PROPOSED SPRINT (1) ANTENNA MOUNT (CONNECT -IT JPVTM10-3-4-126) (REFER TO SHEET A-4 FOR DETAIL) INSTALL EXISTING RELOCATED (1) RRUS-11 &.(1) RRUS-31 B25 ON EXISTING BACK TO BACK RRU MOUNT INSTALL EXISTING RELOCATED (1) DIPLEXER INSTALL PROPOSED SPRINT ANTENNA (1 PER BETA & GAMMA SECTORS, 2 TOTAL) SF,O P�ti OAP _ PRpePN-��J OFL e�P SFC( INSTALL EXISTING RELOCATED (1) RRUS-11 & PROPOSED (1) RRUS-82 ON PROPOSED BACK TO BACK RRU MOUNT "0 0 . ,PFc�;GlG 9� 2F o,�ogy� o.tiyq q 210' AGL q2 i4'C sFCT ��ygtiT qfA s• �q I yq EXISTING (1) DIPLEXER TO REMAIN FOR PROPOSED GAMMA SECTOR EXISTING SPRINT ANTENNA MOUNT TO BE MODIFIED (1 PER SECTOR, 2 TOTAL) EXISTING (2) DIPLEXER TO BE REMOVED EXISTING TMA TO BE REMOVED (1 PER SECTOR, 2 TOTAL) EXISTING (1) RRUS-11 & (1) RRUS-31 B25 ON BACK TO BACK RRU MOUNT TO BE RELOCATED TO PROPOSED BETA SECTOR EXISTING (1) RRUS-11 ON BACK TO BACK RRU MOUNT TO BE RELOCATED TO PROPOSED BETA SECTOR EXISTING (1) OIPLEXER TO REMAIN FOR PROPOSED ALPHA SECTOR 21C EXISTING (1) DIPLEXER TO BE RELOCATED AGL TO PROPOSED ALPHA SECTOR EXISTING ANTENNA AZIMUTH BY _ SECTOR BETA EXISTING SPRINT ANTENNA TO BE REMOVED (1 PER SECTOR, 2 TOTAL) EXISTING (1) DIPLEXER TO BE REMOVED 2 EXISTING ANTENNA PLAN SCALE: N.T.S. NOTE: RRUS ARE TO BE POWERED UP WITHIN 24 HOURS OF PLACEMENT ON THE TOWER. DO NOT OPEN RRU PACKAGES IN THE RAIN. 3 PROPOSED ANTENNA PLAN - FINAL SCALE: N.T.S. (1) RRUS-31 B25 ON BACK RRU MOUNT TO REMAIN POSED ALPHA SECTOR NOTE: CONTRACTOR TO FIELD NOTE: THESE PLANS WERE VERIFY ALL DIMENSIONS. COMPLETED USA ENGINEERING'S MOUNT ANALYSIS DATED MAY 02, 2018. INSTALL PROPOSED (1) RRUS-11 & (1) RRUS-82 ON PROPOSED BACK TO BACK RRU MOUNT EXISTING RELOCATED (1) DIPLEXER PROPOSED ANTENNA AZIMUTH 90' _ SECTOR ALPHA INSTALL PROPOSED SPRINT ANTENNA (2 PER ALPHA SECTOR) INSTALL PROPOSED (1) RRUS-31 B25 ON EXISTING BACK TO BACK RRU MOUNT WITH EXISTING (1) RRUS-31 325 PROPOSED ANTENNA MOUNT MODIFICATIONS R ALPHA & GAMMA SECTORS) TO SHEET A-4 FOR DETAILS) Sprinit 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 CCCROWN CASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA, FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY STAMP: 5 9l:p-� �Ty� ♦+� P�G C E jd®� % d No 72513 � a ..fie e�o 9®m'� '• ORIII Q N�♦♦` MARC MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: 05/09/18 USA END. JOB NO, 12180002-09 REVISION NO DESCRIPTION BY DATE A PREUMIRARY CD'S REV 'A' BMF OS 09/18 0 REV 0 CDs ISSUED BMF OS 16 18 SHEET TITLE: ANTENNA PLANS & DETAILS SHEET NUMBER: A-2 C , � ANTENNA TILT BRACKET PROVIDED W/ANTENNA PROPOSED PIPE MOUNTING BRACKET PROVIDED ANTENNA PROPOSED PIPE MOUNTING BRACKET PROVIDED W/ANTENNA ro MAST PIPE 8.2" 1 8.5" 0 o I I 47.5" 11:8" 72.0" 7.9" �(l 9b ANTENNA MOUNTING DETAIL SCALE:N.T.S. ANTENNA DETAIL - ANTENNA DETAIL - ANTENNA DETAIL - 2 #TTTT65AP-1XR 3 #HPA33R-CS4AA-K1 4 #APXV9ERR-C-A20 SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. _ ERICSSON RRUS 11 _ - ERICSSON RRUS 82 —DIMENSIONS (H x W x D): ERICSSON RRUS 31 B25 17.0" x 17.8" x 7.2" (INCLUDES SUNSHIELD) —DIMENSIONS (H x W x D): —WEIGHT: 44 LBS —DIMENSIONS (H x W x D): 23.0" x 15.0" x 7.0" (INCLUDES SUNSHIELD) —CLIMATE: 40'C TO +55'C 16.5" x 11.8" x 9.3" —WEIGHT: 58.9 LBS (WITHOUT SUNSHIELD) ,(SELF CONVECTION SILENT, NO fANS, IP55) - -POWER CONSUMPTION: 80 WATTS (TYP.) NOTE, RRUS CAN ONLY BE PAINTED ON SOLAR SHIELD. 5 RRUS-82 DETAIL SCALE:N.T.S. i f NOTE: RRUS CAN ONLY BE PAINTED ON SOLAR SHIELD. 6 RRUS-11 DETAIL SCALE:N.T.S. RRUS-31 B25 DETAIL 7 SCALE:N.T.S. m ANTENNA MAST PIPE ANTENNA 1 ERICSSON RRU SUPPORT KIT PART #SXK 109 1946/1 AND #SXK 109 1946/2 (OR APPROVED EQUAL) RRU DETAIL IS DIAGRAMMAIIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED - FOR ANTENNA CONFIGURATION. BACK VIEW FLE CQmpE- RRU ANTENNA MAST PIPE ERICSSON RRU SUPPORT KIl PART #SXK 109 1946/1 AND #SXK 109 1946/2 (OR APPROVED EQUAL) NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. SECTION A RRU MOUNTING DETAIL 8 SCALE:N.T.S. PREPARED FOR: Sprint � 6391 SPRINT PARKWAY OVERLAND PARK,j KS 66251 CROWN CCCASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA, FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY STAMP,`�ei`YC a'�s,00'rk c-•. B No 72513 m " ST&T ,•lU< ✓ . �00 M/8p�6%2018 MARC MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: OS/09/18 USA ENS. JOB NO: 12180002-09 REVISION NO DESCRIPTION BY DATE A PRELIMINARY CO'S REV 'A' BMF'05 09/18 0 REV 0 CDs ISSUED BMF OS 16 18 SHEET TITLE: DETAILS SHEET NUMBER: A-3 PROPOSED CONNECTION (SITE —PRO (� #SAM—U) 3 I PROPOSED TIE —BACK (2.375. O.D. SCH 40 GALV. PIPE) (CUT TO LENGTH IN FIELD) PROPOSED V—STYLE STABIUZER (CONNECT —IT #VSK—T) PROPOSED CONNECTION (SITE —PRO #SAM—U) .� MOUNT MODIFICATION DETAIL SCALE:N.T.S. (CONNECT -IT #PVFM10-3-4-126) ANTENNA MOUNT DETAIL 2 SCALE:N.T.S. PROPOSED FACE PIPE (2.375" O.D. SCH 40 GALV. PIPE) (13'-0"3 LONG) (SOLD SEPARATELY) EXISTING STIFF —ARM MAY VARY EXISTING MOUNT MAY VARY CROSSOVER PLATES (SOLD SEPARATELY) NOT INCLUDED WITH MOUNT REINFORCEMENT KIT (CONNECT —IT #COP2-2) UN PROPOSED FACE PIPE (2.375" O.D. SCH 40 GALV. PIPE) (8'-0"t I LONG) (SOLD SEPARATELY) CROSSOVER PLATES (SOLD SEPARATELY) NOT INCLUDED WITH MOUNT REINFORCEMENT KIT (CONNECT —IT #COP2-2) (CONNECT -IT #VSK-T) V-STYLE STABILIZER KIT DETAIL 3 SCALE:N.T.S. B 1 13 1 12NA I NUT- O/2-13 mom 10 8 12 12LW WASHER, LOCK- 01/2' 8 11 12FW WASHER, MT- 01/2' 4 10 UBT2-x5-4 U-BMT- 01/2'-13 2.5x4' NOTE 10 1 2 SDX2 X-OVER PULE A36 GALV S1EEL 7 COP2-2 X-OVTR PULE A55T. VARIOUS- 1 ON PART OR IDEMIFWIG NO. NOMENLUTURE _ MATERIAL ECINDATION OR REMARKS 0AD REOM S/ STD 0 PARTS UST (CONNECT -IT" #COP2-2) CROSS -OVER PLATE DETAIL 4 SCALE:N.T.S. L 1 71� rv�`­ C uo-,- X�E mF0.411 WJMF1 WU�I 13] x74 3 x GI]A-10 Y G.) O.m l.lx 41 l GI2113 Kl ll HMm WLT NI'[I1/Y XW XIXBOLTGPS IRN O.LS 0.15 1 3 G]N3 1?[S NW IR%B0.TG0.5RLLiMFPO 31n O.II 0.43 6 8 GIEW 1/SXCG VS]4TV0.91EA 0.03 G.Z] ] GiSW 1?YDG IL(%WI514A 0.01 0,10 G ) 1/wa-X W]NM O.W OSO 9 1 WW G593]] T 3/B'[Y1/Y1NGBl4T 11/3N 033 0. 10 1 GSOLW 3Bsm...0-03 0.0303 11 1 G3NAR 5/SISG HFAW LIXIX WIf 0.13 ..13 1x 1 SOM $i6inAHMMirMM1'f 0n an 13 1 as aArssxNF ua•rmac sya•Lauc ass a.ss (SITE -PRO #SAM-U) 5 PIPE TO PIPE CONNECTION DETAIL SCALE:N.T.S. Sprint® 6391 SPRINT PARKWAY OVERLAND (PARK, KS 66251 Cis CROWN � C CASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA, FL 33614 GIENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY P. CEI NO 72513 �: * TATE OF -.(Tj MARE MA199f P23BBB►B•-- FL PROFESSIONAL ENGINEER LIC. # 72513 DRAWN BY: BMF APPROVED BY: MM DATE DRAWN: 05/09/18 USA ENG. JOB NO: 1 12180002-09 DETAILS A-4 COLOR CODE CHARTS BELOW ARE REFERENCED FROM EXHIBIT H01 - TS-200 ISSUE 5; ANTENNA TRANSMISSION LINE ACCEPTANCE STANDARDS COAXIAL / HYBRID CABLE COLOR CODE SAMPLE SECTOR CABLE FIRST RING SECOND RING THIRD RING 1 ALPHA 1 - NO TAPE NO TAPE 1 2 3 NO TAPE NO TAPE �Bli NO TAPE NO TAPE 1 1 4 WHITE NO TAPE NO TAPE 1 5 6 NO TAPE NO TAPE GREY_ NO TAPE NO TAPE i 1 7 8 NO TAPE NO TAPE NO TAPE NO TAPE 1 2 BETA 1 2 NO TAPE NO TAPE LBBOS'.'N� B NO TAPE WHITE WHITE NO TAPE 2 2 3 2 4 2 5 6 NO TAPE NO TAPE 2 2 7 NO TAPE NO TAPE WHITE I WHITE WHITE 13MGMILTGREY,- GREY -F 2 g 1 2 3 GAMMA 3 3 3 4 5 6 3 3 7 8 3 FREQUENCY / RADIO COLOR CODE FREQUENCY/RADIO INDICATOR ID 800 #1 YELUow 1900 #1 YELL`, W� 1900 #2 Y1B.E'OW -IM YELLOW iYEkL�d§W� �B OR WNW I�GREY 1900 #3 1900 #4 Boo #2 �YELL20O 1 WHITE 2500 #2 2500 MHz RADIO CALIBRATION CABLE COLOR CODE 2500 MHz #1 CAL CABLE - SECTOR CABLE FIRST RING SECOND RING THIRD RING FORTH RING FIFTH RING SIXTH RING 1 ALPHA 1 - O WHITE 2 BETA 2 . _ WHITE 3 GAMMA 3 Q. A L. ,'. - _ Y.pLL' WHITE 2500 MHz #1 CAL CABLE - SECTOR CABLE FlRST RING SECOND RING THIRD RING FORM RING FIFTH RING SIXTH RING 1 ALPHA 1 AMIRWRawm Ow 2 BETA 2 M.. _ 3 GAMMA 3 a�9 Example — Sector 2, Cable 2, 800mhz Radio #1 IIIIi � 11 Example — Sector 3, Cable 1, 1900mhz Radio #1 rlrw�.Lun Example — Sector 1, Cable 4, 800 mhz Radio #1 and 1900mhz Radio #1 PREPARED FOR: Sprint' 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 CROWN v CASTLE 4511 N. HIMES AVENUE, SUITE 210 TAMPA, FL 33614 ®IENGINEERING 2818 CYPRESS RIDGE BOULEVARD SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 R. COA #31705 SITE NAME: MINUTE MAID SITE NUMBER: M113XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE_ COUNTY STAMP: a/ G �• M 'ws E Al g'lc'%9�♦c eeeeee�P-�\G ® No 72513 BB®° sS�O11fA�-E�� oe ®119191 11g�9 MAY 118 MARC MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 DRAWN BY: BMF APPROVED BY: MM 1 DATE DRAWN: 05/09/18 USA ENG. JOB NO: 12180002-09 REVISION NO DESCRIPTION BY DATE A PREUMINARY CD'S REV •A- BMF 05/09 18 0 REV 0 CDs ISSUED BMF 05/16 18 SHEET TITLE: COLOR CODING SHEET NUMBER: A-5 DDnansFn ANTENNA AND CABLE SCHEDULE tlgIFS TOWER EOOPIAHT SECRM AZ CENTT ItAbjER'R ANTENNA MWE MODEL ((0pIIYY)) (OTYJ APPROXBNTE ANTENNA SPEOS I'LEMMIPER MODEL 1 SIM QI1tl1R11' IBNIE MODEL (011') ALPHA (A1) ALPHA90' 210-0' RFS/CELWAVEC-A20 7EIM 1 H-]2.0' X W-11.8' X D-].9' ERICSON TSZ 999 066/xxxM-HAWG 1-1/32' 1 260'-0'(1) RFS/CELWAVEDIPLE%ER_ _ (1) RRUS-11. (1) RRUS-82 2 ALPHA (A2) - _ _ ALPHA (AE) 90' 210'-0- COMMSCOPE1XR 1 H-63.3' X W-12.0' X D-4.6' - - - - (i) RFS/CELWAVE - DIPLEXER, Q) RRUS-31 B25 2 (1) RRUS-31 B25 1 ALPHA (A3) - - - ALPHA (A4) - - - - - - - - - BETA (131) BETA (B2) BEFA (53) _ 240' _ 210"-0' _ CCI _ HPA33R-054PA-K1 _ - _ - _ 1 _- H-47.5' % W-18.2' % D-8.5' ERICSON TSZ 999 066/xxxM-BAWG 1-1/32' 1 260'-0 (2) RRUS-11, (1) RRUS-31 B25 3 _ _ (1) RRUS-82 1 BEFA (B3) - - - - - - - BETA (B4) _ - - - -_ GAMMA (G1) - - - - - - - - - - GAMMA (G2) GAMMA (G2) - 320 - 210"-0' - RFS/CELWAVE - HPA33R-054A4-K1 - - - - - 1 - H-4].5' % W-18.2' X D-8.5' - ERICSON TSZ 999 066/xxxM-6AWG - 1-1/32' - 1 - 260'-W (1) RFS/CELWAVE - DIPLEXER 1 (1) RRUS-82 1 GAMMA (G2) - - - - - - GAMMA (G3) - - - - - - - - - - - - GAMMA (G4) _ _ _ _ _ _ _ _ TOTAL CAB!E (FDOSRNG) 2 520'-0' TOTAL 12 TOTAL CABLE (PROPOSED) i 260'-0' "CONTRACTOR TO VERIFY RF INFO WITH CUENT PRIOR TO CONSTRUCTION. •CABLE LENGTHS ARE APPROXIMATE AND MUST BE VERIFIED PRIOR TO CONSTRUCTION. •ALL CABLES SHALL BE COLOR CODED. PROPOSED CABLE SNAP IN HANGER ROSENBERGER PART NO. 1H496-DC114 OR EQUIVALENT HANGER ADAPTER GROMMET — ROSENBERGER PART NO. CX609-HAOT20 OR EQUIVALENT DOUBLE CLAMP 2 HANGER ADAPTER GROMMET DETAIL SCALE:N.T.S. ANTENNA & CABLE SCHEDULE SCALE:N.T.S. CABLE SUPPORT BLOCK MOUNTED C G WITH STAINLESS STEEL STRAPPING TO MOUNTING PIPE RRU L I- RU NOTES: .�_. POWER • EXCESS FIBER OPTIC RRU JUMPER CABLES SHALL BE CABLE COILED AND SECURED TO THE ANTENNA/RRU SUPPORT STRUCTURE USING APPROVED CABLE SUPPORT BLOCKS. • FIBER JUMPER STORAGE COILS SHALL BE PLACED AS CLOSE TO THE RRU AS POSSIBLE. 2" MARINE FIBER 2" OUTDOOR RATED VINYL TAPE OR OUTDOOR (UV) RATED GRADE MARINE JUMPER VELCRO WRAPS WILL BE UTILIZED TO BUNDLE FIBER COILS. GRAD OF LC EXCESS HYBRID FIBER SHALL NOT BE COILED ON THE ANTENNA SUPPORT STRUCTURE. • FIBER OPTIC COILS AND BENDS SHALL NOT BE LESS THAN MOUNTING PIPE THE MANUFACTURER'S BEND RADIUS TO ANTENNA 3 EXCESS CABLE CONTROL DETAIL SCALE:N.T.S. Sprint® 011.0 6391 SPRINT PARKWAY j OVERLAND PARK, KS 66251 I CROWN v CASTLE 4511 N. MIMES AVENUE, SUITE 210 TAMPA, FL 33614 GIUSA 2818 CYPRESS RIDGE BOULEVARD SURE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 MINUTE MAID SITE NUMBER: MI13XC160 SITE ADDRESS: 2651 MINUTE MAID ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY P. No 72513 ® _ o dF MAY T61109100 " MARC MAIER, PE FL PROFESSIONAL ENGINEER LIC. 111 72513 DRAWN BY: BMF APOV PRED BY: MM DATE DRAWN: 05/09/18 USA ENG. JOB NO: 12180002-09 DETAIL SHEET A-6 PREPARED FOR: n n 1A_ WIRE SIZE BURNDY LU BOLT SIZE TIN COATED -SOLID COPPER BUSS BB PER SPRINT SPECIFICATIONS 2 HOLE, LONG BARREL TINNED SOL10 COPPER LUG (TYP.) NOM MINIMUM OF 3 THREASS TO BE VISIBLE (TIP.) S/S FIAT WASHER S/S FIAT WASHER OYPJ S/S BOLT mP.) Sprint' 6391 SPRINT PARKWAY I OVERLAND PARK, KS 66251 /'OP% r.173f-%%Ain1 #6 AWG GREEN INSULATED YA6C-2TC38 3/8" — 16 NC S 2 BOLT #2 AWG SOLID TINNED YA C-2TC38 3/8" — 16 NC S 2 BOLT Ig2 AWG STRANDED YA2C-2TC38 3/8' — 16 NC 5 2 BOLT #2/0 AWG STRANDED YA26-2TC38 3/8' — 16 NO S 2 BOLT #4/0 AWG STRANDED YA28-2N 1/2" — 16 NC S 2 BOLT S/S NUT (TYP.) \i`I/Jw CASTLE BURNDY GROUND LUG S/S SPLIT WASHER / (SEE TABLE FOR SIZE (TYP.) 4511 N. SUIHIMTE 2 AVENUE, / AND MODEL) HEAT SHRINK CHERRY INSULATOR SUITE 21 O / (CLEAR) INSTALLED IF TAMPA, FL 33614 / SPRINTED PER / NUT (TIP.) GROUNDING SPRINT / CONDUCTOR SPECIFICATIONS NEW FILTER UNIT / S/S SPLIT WASHER QYP.) (AS REQUIRED) / NEW TOP S/S FIAT WASHER (TYP.) JUMPER NOTES. ® USA NGINEE RING I /� CABLE 1. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING SPUR WASHERS. / 1 GROUND 2. COAT WIRE END WITH ANTI -OXIDATION COMPOUND PRIOR TO 2818 CYPRESS RIDGE BOULEVARD NEW RRU SURE 110 FILTER TO / UNIT BAR BOLT (rmJ INSERTION INTO LUG BARREL AND CRIMPING. GROUND / 1 (TYP;) Nye 3. APPLY ANTI -OXIDATION COMPOUND BETWEEN ALL LUGS AND BUSS WESL(8 CHAPEL, 365 33544 BAR / 1. ALL HARDWARE BOLTS. NUTS, (FL C)OA9#311705 / LOCK WASHERS BURNDY TWO HOLE LUG WITH BARS PRIOR TO MATING AND BOLTING. / SHALL BE STAINLESS STEEL LONG BARREL FOR #6 AWG SITE NAME: ALL HARDWARE ARE TO BE AS STRANDED OR EQUIVALENT GROUNO //RED TO/ / NEW DC FOLLOWS' BOLT, FLAT WASHER, BAR / i i JUMPER GROUND BAR, GROUND LUG, FLAT 4 LUG DETAIL MINUTE MAID WASHER AND NUT. BARE WIRE TO BE / / NO-OX AT BOTH ENDS NOT J0 SCALES / I 2. COPPER SHIELD, ANTIOX, CR � f I CI ALE ' / A SITE NUMBER: / / / NO—OX OR EQUIVALENT V L.11 F5 Y I 11 ' / STRANDED GREEN / / SHALL BE PLACE WHERE ALL INSULATED 4pFtk�� MI13 160 .SIMPER NEW ER DISSIMILAR METALS CONNECT. CONDUCTOR Eli .. / CABLE 3. ALL LUGS PRE TO BE INSTALLED #6 AWG E OM SITE ADDRESS: PER MANUFACTURER'S ANTENNA CABLE 2651 MINUTE MAID ROAD SECTOR % NEW BREAK SPECIFICATIONS. GROUND KIT FORT PIERCE, FL 34945 OUT ClJNDERS caoene ST. LUCIE COUNTY STAMP: MECHANICAL LUG CONNECTION COPPER GROUND ®,,eggiY�i��®� BAR ON WALL. ICE C' I NEW BRIDGE, FLOOR OR \ 2 NOT TO SCALE \ P •.° ° IV CABLE C HYBRID ON ANTENNA TOWER N 00 ®\ e��0 E 1VcoLLUPPEN = No3GROUND\BAR °TWO HOLE EXOTHERMIC GROUNDING SHALL BEBE USED ELIMINATED WHEN G i ° AWG BCW TO BUILDING CABLE TO iv¢ SERVICE GROUND OR GROUND BAR IS ® ' 9E • $ GROUND BAR �� ELECTRICALLY BONDED ® \•• �.• + VqO, _ _ GROUND RING ✓ �i� LOWER ANTENNA CABLE c - TO METAL TOWER O®I v,h�•0 R t O••e�� \\ (TYPICALLY). 0 t 21— T B � rR,3 qy4 GROUNDBAR F- 120" MAX. I SB /O �i' 44 P -- 5F GROUNDWIRE DETAIL MARC MAZER, PE NOT TO SCALE � FL PROFESSIONAL ENGINEER LJC. /f 72513 WEATHERPROOFING KIT (SEE DRAWN BY: BMF NOTE 3) APPROVED BY: MM V TO ANTENNA COAX DATE DRAWN: 05/09/18 CABLE GROUND KIT TERRABAR GROUND BAR US4 ENG. JOB N0: 12180002-09 #6 AWG STRANDED COPPER GROUND WIRE REVISION o (GROUNDED TO GROUND BAR). SEE NOTE 1& 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NO DESCRIPTION BY DATE i 0 0 0000000000000 Exlsnuc CABLE CONNECTOR 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 A PRELIMINARY CD'S REV 'A' BMF OS 09/18 POWER ExlsnNc 0 REV 0 CDs ISSUED BMF 05/16 18 CABINET CABINET #2 SOLID TINNED COP3ER TOWER NG GROUNDi RI TO TOWER )HOLE LONG BARREL COMPRESSION LUG BOTTOM GROUND BAR ONLY) o I NOTES: G 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND NOTES. 3 / WIRE DOWN TO GROUND TAR. / 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. ,0 MASTER 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR GROUNpoeeOeeeeeoa! RECOMMENDED 6Y CABLE MANUFACTURER. 2. GROUND MR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). BAR 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT 3. INSTAL. GROUND BARS AT 75 FT. INTERVAL MAXIMUM. SHEET TITLE: BE USED. 4. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. GROUNDING DETAILS SHEET NUMBER: GROUNDING RISER DIAGRAM 3 CABLE GROUND KIT CONNECTION 6 TOWER GROUND BAR DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE G 1