Loading...
HomeMy WebLinkAboutEVALUATION REPORTOO SCANNED BY St. Lucie County NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-RS One Owens Corning Parkway FL11602-RS Toledo, OH 43659 Date of Issuance: 11/03/2008 (740) 321-6345 Revision 5: 04/19/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 611, Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium?' Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: "onnr jC''.� ZI Robert J.M. Nieminen P.E. ?'•, - cTs:;•,: •°FS�:,;, facsimileseal Florida ;..�„•,. The appear04/19/ingwashis `�. Registration No. 59166, Florida DCA ANE1983 dorized wned serve ;�"� �,..•'• Nieminen, P.E. on o4/19/Zo18. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titaniumm Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARD Section Pro a Standard Year 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1,1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 i'-3. REFERENCES: Enti Examination Reference Date ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08,11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) TAS 117(B); Pull -through OCF-422.02.02 04/03/2018 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4.1 Self -Adhering Underlavments: 4.1.1 TitaniumTM PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer - coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. Meets ASTM D1970 as a single -layer and meets FRSA/TRI April 2012 when used in 2-ply system. Mechanical) Fastened Underla ments: '4.2. 1tanium— UDL-2S is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.2 TitaniumTM UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.3 TitaniumTM UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on bath sides with a polymer coating. Unit weight 4.7 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception). NEMO ETC, LLC Evaluation Report 111980.11.08-RS Cert/1lcate ofAuthori:utlon#32455 0EDITION (2017)FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 2 of 7 NNEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium' Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt Wood Shakes Underlayment Shingles Nail -On Tile Foam -On Tile Metal &Shingles Slate Titanium PSU-30 Yes Sil (vassa, India) s Yes (See 5.5.1) Yes Yes Yes Titanium PSU-30 (Brentwood, NH) ` No- ; No " Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL$U KYe(Basesheesm2-ply (Base sheet in] -ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. 5.6 Allowable Substrates: Titanium PSU-30: 5.6.1 Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet: ➢ ASTM D226, Type I or II felt. ➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted). ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 111980.11.08-RS Certificate clAuthonzation#32455 Gm EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5 Titanium Roof Underlayments Revision 5: 04/19/2018 Page 3 of 7 ONEMO etc. 5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not addresswind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04.12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -45 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30 (Silvassa, India), self -adhered q2 Maximum Design Pressure = -30 osf': Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered #3 Maximum Design Pressure = -30 osf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-inch D.C. at 4-inch wide side laps and 12-inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered #4 Maximum Design Pressure =-45 osf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps Spacing: 6-inch D.C. at 4-inch wide side laps and 8-inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Silvasso, India), self -adhered NEW ETC, LLC Evaluation Report 111980.11.08-R5 Certificate of Authorization 432455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 51 04/19/2018 Page 4 of 7 ONEMID etc. #5 Maximum Design Pressure =-45 psf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 (Silvassa, India) shall not be left exposed for longer than 90-days. Titanium PSU-30 (Brentwood, NH) shall not be left exposed for longer than 30-days. 5.8 Tile Slippage Limitations [per FRSA/TRI April 2012 (04-1211: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. FORDIREcr-DEcKTILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 (Silvassa, Flat Max. 10-tile stack 5:12 India) Lugged Max. 30-tile stack 6:12 6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). NEMO ETC, LLC Evaluation Report 111980.11.08-RS Certificate of Authorization M32455 6TM EDITION (2017)F8C NON-HVRZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 5 of 7 *NEMO etc. 6.3 Titanium'" UDL-25, Titanium UDL-30 or Titanium UDL-50: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-Inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-Inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, VWo equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium'" UDL-25, Titanium UDL-30 or Titanium UDL- 50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Slooes of 4:12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c, horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: Double layer application; begin by fastening a 25-Inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25- inch side (horizontal) laps, resulting in a double -layer application. 6.4 Titanium•" PSU-30: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Cover: Cut manageable sections and re -roll with the release film side out. Membrane Application: ➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. ➢ Apply subsequent courses parallel to the eave In a shingle -type, water -shedding manner. ➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches. ➢ If the membrane becomes misaligned, cut the roll and re -start. ➢ Upon completion, inspect the membrane and repair any defects or fish -mouths. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. NEMO ETC, LLC Evaluation Report 111980.11.08-RS Certificate ofAuthonzatton N324SS 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5 Titanium Roof Underlayments Revision 5: 04/19/2018 Page 6 of 7 *NEMO etc. 6.4.3 Tile Applications [Titanium PSU-30 (Silvassa, India) onlvl: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading of roofing tiles. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. 6.5 I Titanium 2-Ply System: 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30 (Silvassa, India), self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3 followed by Titanium PSU-30 (Silvassa, India) in accordance with Section 6.4. 6.5.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened the roofing, refer to Owens Corning Roofing and Asphalt, LLC published installation instructions, but not less than the fastener density from FRSA/TRI April 2012 (04-12), Table 1, taking into account the wider sheet -width. For adhesive -set tile roofing, refer to Section 5.6.3 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading of roofing tiles. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. As required by the Building Official or Authority Having Jurisdiction'in order to properly evaluate the installation of this product. Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant. - -,Specification Products Mission, BC, Canada FBC 1507.1.1(Exception) Titanium UDL-30; Titanium UDL-50 Qingdao, China FBC 1507.1.1(Exception) Titanium UDL-25; Titanium UDL-30; Titanium UDL-50 Silvassa, India FRSA/TRI 04-12 (2-ply system) Titanium PSU-30 (Silvassa, India) Brentwood, NH ASTM D1970 Titanium PSU-30 (Brentwood, NH) QUALITY19. Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11.08-RS Certificate ofAutharization N32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 7 of 7 C R E'I rl i � Certificate of Authorization No. 29824 1F�, 11Ki 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017 220 West 4'h Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin, MO SCANNEDPhillipsburg, KS Frederick, MD BY Dallas, TX St. Lucie County Tuscaloosa, AL ty Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5. 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02-01 TAS 100 1995 PRI Constrri�ction Materials Technologies (TST5878) TAP-314-02.01 Rev 2 TAS 100 1995 PRI ConstMclion Materials Technologies (TST5878) TAP-315-02.01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 2010A UL LLC (TST9628) 05NK28006 ASTM D 6381 2008(2013)el UL 2390 ASTM D 7158 2011 UL LLC (TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) OBCA59132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 10CA50498 ASTM D 3462 2010A UL LLC (TST9628) 10CA64882 ASTM D 3161 2016 UL LLC (TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 12CA24551 ASTM D 3161 2016 UL LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)el UL LLC (TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass -Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 34ab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass a a , re Brick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg & complying with ASTM D 3462. Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Vintage® 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC INSTALLATION TAMKO BUILDING PRODUCTS Asphalt Shingles Elite GlassSeal® Basic Wind Speed (V"it): Max. 194 mph (Frederick, Joplin & Basic Wind Speed (Vag): Max. 150 mph Tuscaloosa) Deck (HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass -Seal new construction; Min. 15132 in. plywood existing (Frederick, Joplin (Non- construction. HVHZ) & Tuscaloosa) Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 16/32 in, plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min, slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when Installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nall Pattern" detailed below. \nstallation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. ." Figure 1. Elite G 4 Nail Pattern Butt Edge Glass -Seal � only) Butt Edge Figure 2. Elite Glass -Seal & Glass -Seal 6 Nail Pattern 1411- l 5.1/8" 6.7/8'r 5.118" TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS yyt Asphalt Shingles N t TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed (Vut): Max. 194 mph (Dallas, Frederick, Joplin, Basic Wind Speed (V," ): Max. 150 mph Phillipsburg & Tuscaloosa) Deck (HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage® Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg & Tuscaloosa) Deck (Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for HeritageO Woodgate new construction; Min. 7/16 in. OSB existing construction. (Dallas & Frederick) Undedayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 3. Heritage@, Heritage@ Premium, 4 Nail Pattern (non. FASTENERS i" I-T-1/2"►0- NAIL ZONE BOND EXPOSU RE 5-6/8" NAIL ZONE COMMON BOND EXPOSURE 5-5/8" Figure 4. Heritage@ & Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall n Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes specifically addressed herein. i4of 11 CREEK is valid. are not CREEK TECHNICAL SERVICES, LLC PAINT 7-718" 6-118" TAMKO BUILDING PRODUCTS Asphalt Shingles NAIL ZONE/ COMMON BOND - T EXPOSURE 5 5/8" /2'I►�7.3/8�7-1/2�7.1l2+I►I �-1" Figure 5. Heritage@ Woodgate 6 Nail Pattern FASTENERS Figure 6. Heritage@, Heritage@ Alternate 6 DO NOT FASTEN ALONG EDGE OF COMMON BOND PREFERRED FASTENER LOCATION 12.1 El Common Bond 8 Heritage@ Woodgate ZONE Figure 7. Heritage@ (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK "rt TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (V�it): (Frederick) Basic Wind Speed (V,,): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in, plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application Instructions when installing shingles at slopes greater than 21:12. . Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NAIL ZONE! COMMON BOND 5" 12" Figure 8. Heritage® 4 Nail Pattern (, 11 "--►� Imo_ _ i n (Frederiicckk) V only) 5" 1 �� �91h�—'1'9'I'— 9"---►�3L►�--9Va" IF-1 Figure 9. Heritage® Premium (Frederick) 6 Nail Pattern ZONE/ NON BOND IbH1buur.4 FL18355-R4 i This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall n, Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes specifically addressed herein. ,6 of 11 CREEK is valid. are not CREEKr TECHNICAL SERVICES, LLC Heritage® Woodgate Basic Wind Speed (V"u): (Frederick) Basic Wind Speed (V,,): Deck (Non-HVHZ): 5-112 1" 1 Underlayment: Min. slope: Installation (Non-HVHZ): Figure 10. 1- 4 Nail TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturers application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. BOND r---1 T EXPOSURE 5" f iin � �in ® Woodgate (Frederick) (non-HVHZ only) BOND 1 T 5'1t/7' IXPOBURE 5" S r �t 1"-- �- 9-1/2" -q4-3'+-93l8"43+ 9-1/2" -X �11--1" Figure 11. Heritage® Woodgate 6 Nail Pattern FL18355-R4 7 of 11 i nis evamanon report Is prowaea Tor State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKrdi i TECHNICAL SERVICES, LLC Heritage® Vintage® Basic Wind Speed (Vvil): (Phillipsburg) Basic Wind Speed (V,sd): Deck(HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in, plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "5 Nail Pattern" or "6 Nail Pattern" detailed below. uwsm , No%h Figure 12. Heritage® Vintage® 5 Nail Pattern (n -HVHZ only) Figure 13. Heritage® Vintage 6 Nall Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Hip & Ridge Basic Wind Speed (Vml): (Frederick & Joplin) Basic Wind Speed (V,,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. DEB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturers published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction prevailing wind exposure Figure 1 Ian 1 1' Fastener Figure 2 Figure 14. Hip & Ridge (Frederick & Joplin) )xposure TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK LAO TECHNICAL SERVICES, LLC Vintage@ Hip & Ridge Basic Wind Speed (V,u): (Philkpsburg) Basic Wind Speed (Vag): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Direction of TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. wind Figure a-- exposure Fasten_ er Figure 2 lr4 Figure 3 Figure 15. Vintage@ Hip & Ridge (Phil) sl urg) FL18355-R4 10 Of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKTAMKO BUILDING PRODUCTS 1 Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. r'oR�F���i .`�,`G�P�G E N. s: •�� 2017.09.25 No 74021 11:31:41 _ -04'00' %53 . STATE OF , XN '.A14 0 P.� Zachary R. Priest, P.E. l�sSj0NM- OganiationNoFlorida .ANE11669on No. 1 %%`%,, CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest In any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein.