ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-RS
One Owens Corning Parkway FL11602-RS
Toledo, OH 43659 Date of Issuance: 11/03/2008
(740) 321-6345 Revision 5: 04/19/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 611, Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Titanium?' Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
"onnr
jC''.�
ZI
Robert J.M. Nieminen P.E.
?'•, - cTs:;•,:
•°FS�:,;, facsimileseal
Florida
;..�„•,. The appear04/19/ingwashis
`�.
Registration No. 59166, Florida DCA ANE1983
dorized wned serve
;�"� �,..•'• Nieminen, P.E. on o4/19/Zo18. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMO etc.
ROOFING COMPONENT EVALUATION:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Titaniumm Roof Underlayments, as produced by Owens Corning
Roofing and Asphalt,
LLC, have demonstrated
compliance with the intent of
the following sections of the 6t6 Edition (2017) Florida
Building Code through testing in accordance with applicable
sections the following Standards. Compliance is
subject to the Installation
Requirements and Limitations /
Conditions of Use set forth herein.
STANDARD
Section
Pro a
Standard
Year
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength, Pliability ASTM D226
2009
1507.1,1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
1507.1.1, T1507.1.1,
Physical Properties
ASTM D1970
2015
1507.2.9.2
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
TAS 110
Accelerated Weathering
ASTM D4798
2011
TAS 110
Pull -through resistance
TAS 117(B)
1995
i'-3. REFERENCES:
Enti
Examination
Reference
Date
ERD (TST6049)
Physical Properties
115010.04.09
04/29/2009
ERD (TST6049)
Physical Properties
115010.05.10
05/14/2010
ERD (TST6049)
Physical Properties
135520.06.11
06/15/2011
ERD (TST6049)
ASTM D226
138010.08.11
08/11/2011
ERD (TST6049)
Wind Uplift
135520.08,11-1
08/12/2011
ITS(TST1509)
ASTM D226
311801000Q-003
04/26/2007
ITS(TST1509)
ASTM D226
3130639COQ-002A
08/21/2007
ITS(TST1509)
Physical Properties
3126617COQ-005
10/31/2007
ITS(TST1509)
ASTM D226
101823107COQ-011
01/23/2015
PRI (TST5878)
ASTM D1970
OCF-341-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-331-02-02
10/03/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-332-02-02
10/03/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-334-02-02
10/03/2017
PRI (TST5878)
TAS 117(B); Pull -through
OCF-422.02.02
04/03/2018
ITS (QUA1673)
Quality Control
ITS Listings
Current
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
4.1 Self -Adhering Underlavments:
4.1.1 TitaniumTM PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer -
coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. Meets
ASTM D1970 as a single -layer and meets FRSA/TRI April 2012 when used in 2-ply system.
Mechanical) Fastened Underla ments:
'4.2. 1tanium— UDL-2S is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.5 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception).
4.2.2 TitaniumTM UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight 4.0 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception).
4.2.3 TitaniumTM UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on bath sides with a
polymer coating. Unit weight 4.7 Ibs/square; meets FBC 1507.1.1 & R905.1.1 (Exception).
NEMO ETC, LLC Evaluation Report 111980.11.08-RS
Cert/1lcate ofAuthori:utlon#32455 0EDITION (2017)FBC NON-HVHZ EVALUATION FL11602-RS
Titanium Roof Underlayments Revision 5: 04/19/2018
Page 2 of 7
NNEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Titanium' Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE
1: ROOF COVER OPTIONS
Asphalt
Wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
&Shingles
Slate
Titanium PSU-30
Yes
Sil
(vassa, India)
s
Yes
(See 5.5.1)
Yes
Yes
Yes
Titanium PSU-30
(Brentwood, NH)
` No- ;
No "
Yes
Yes
Yes
Titanium UDL-25
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Titanium UDL$U
KYe(Basesheesm2-ply
(Base sheet in] -ply
Yes
Yes
Yes
system)
system)
Titanium UDL-50
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
5.6
Allowable Substrates: Titanium PSU-30:
5.6.1 Direct -Bond to Deck:
➢ New untreated plywood;
➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond.
5.6.2 Bond to Mechanically Attached Base Sheet:
➢ ASTM D226, Type I or II felt.
➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted).
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 111980.11.08-RS
Certificate clAuthonzation#32455 Gm EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5
Titanium Roof Underlayments Revision 5: 04/19/2018
Page 3 of 7
ONEMO etc.
5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
addresswind uplift resistance of all underlayment systems beneath foam -on tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012 (04.12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -45 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: One or two plies, Titanium PSU-30 (Silvassa, India), self -adhered
q2 Maximum Design Pressure = -30 osf':
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#3 Maximum Design Pressure = -30 osf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Titanium UDL-30 (printed side up)
Fasteners:
12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps.
Spacing:
6-inch D.C. at 4-inch wide side laps and 12-inch D.C. at three (3), equally spaced center rows.
Primer:
ASTM D41 primer required over printed side of UDL-30.
Underlayment:
One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#4 Maximum Design Pressure =-45 osf•:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Titanium UDL-30 (inverted)
Fasteners:
12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps
Spacing:
6-inch D.C. at 4-inch wide side laps and 8-inch D.C. at three (3), equally spaced center rows.
Primer:
ASTM D41 primer required at all tin -caps.
Underlayment:
One or two plies, Titanium PSU 30 (Silvasso, India), self -adhered
NEW ETC, LLC Evaluation Report 111980.11.08-R5
Certificate of Authorization 432455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS
Titanium Roof Underlayments Revision 51 04/19/2018
Page 4 of 7
ONEMID etc.
#5 Maximum Design Pressure =-45 psf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Titanium UDL-25, Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days.
Titanium PSU-30 (Silvassa, India) shall not be left exposed for longer than 90-days.
Titanium PSU-30 (Brentwood, NH) shall not be left exposed for longer than 30-days.
5.8 Tile Slippage Limitations [per FRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
FORDIREcr-DEcKTILE
INSTALLATIONS
Underlayment Tile Profile
Staging Method
Maximum
Slope
Titanium PSU-30 (Silvassa,
Flat
Max. 10-tile stack
5:12
India)
Lugged
Max. 30-tile stack
6:12
6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
NEMO ETC, LLC Evaluation Report 111980.11.08-RS
Certificate of Authorization M32455 6TM EDITION (2017)F8C NON-HVRZ EVALUATION FL11602-RS
Titanium Roof Underlayments Revision 5: 04/19/2018
Page 5 of 7
*NEMO etc.
6.3 Titanium'" UDL-25, Titanium UDL-30 or Titanium UDL-50:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width.
6.3.2 Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-Inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch
diameter heads; ring shank roofing nails with minimum 1-Inch diameter plastic caps; screws and plates; or plastic
cap staples.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, VWo equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the Titanium'" UDL-25, Titanium UDL-30 or Titanium UDL-
50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table
1507.1.1 or R905.1.1.
6.3.3 Slooes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches.
Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c, horizontally in accordance with the
surface markings on the exposed face of the underlayment. When batten systems are to be installed atop the
underlayment, the underlayment need only be preliminarily attached pending attachment of the battens.
6.3.4 Slopes of 2:12 to less than 4:12:
Double layer application; begin by fastening a 25-Inch wide strip along the eaves. Place a full -width sheet over
the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25-
inch side (horizontal) laps, resulting in a double -layer application.
6.4 Titanium•" PSU-30:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Cover:
Cut manageable sections and re -roll with the release film side out.
Membrane Application:
➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place,
printed side up.
➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane
into place.
➢ Apply subsequent courses parallel to the eave In a shingle -type, water -shedding manner.
➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches.
➢ If the membrane becomes misaligned, cut the roll and re -start.
➢ Upon completion, inspect the membrane and repair any defects or fish -mouths.
The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact
Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types.
NEMO ETC, LLC Evaluation Report 111980.11.08-RS
Certificate ofAuthonzatton N324SS 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5
Titanium Roof Underlayments Revision 5: 04/19/2018
Page 6 of 7
*NEMO etc.
6.4.3 Tile Applications [Titanium PSU-30 (Silvassa, India) onlvl:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging.
Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading
of roofing tiles.
The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact
Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types.
6.5 I Titanium 2-Ply System:
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-30 (Silvassa, India), self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3
followed by Titanium PSU-30 (Silvassa, India) in accordance with Section 6.4.
6.5.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened the roofing, refer to Owens Corning Roofing and Asphalt, LLC published installation
instructions, but not less than the fastener density from FRSA/TRI April 2012 (04-12), Table 1, taking into account
the wider sheet -width.
For adhesive -set tile roofing, refer to Section 5.6.3 herein.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging.
Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading
of roofing tiles.
The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact
Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types.
As required by the Building Official or Authority Having Jurisdiction'in order to properly evaluate the installation
of this product.
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant. - -,Specification
Products
Mission, BC, Canada
FBC 1507.1.1(Exception)
Titanium UDL-30; Titanium UDL-50
Qingdao, China
FBC 1507.1.1(Exception)
Titanium UDL-25; Titanium UDL-30; Titanium UDL-50
Silvassa, India
FRSA/TRI 04-12 (2-ply system)
Titanium PSU-30 (Silvassa, India)
Brentwood, NH
ASTM D1970
Titanium PSU-30 (Brentwood, NH)
QUALITY19.
Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321
END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 111980.11.08-RS
Certificate ofAutharization N32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS
Titanium Roof Underlayments Revision 5: 04/19/2018
Page 7 of 7
C R E'I rl i � Certificate of Authorization No. 29824
1F�, 11Ki 17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017
220 West 4'h Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO SCANNEDPhillipsburg, KS
Frederick, MD BY
Dallas, TX St. Lucie County
Tuscaloosa, AL ty
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5. 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-307-02-01
TAS 100
1995
PRI Constrri�ction Materials Technologies (TST5878)
TAP-314-02.01 Rev 2 TAS 100
1995
PRI ConstMclion Materials Technologies (TST5878)
TAP-315-02.01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)el
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
OBCA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
10CA50498
ASTM D 3462
2010A
UL LLC (TST9628)
10CA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)el
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL18355-R4
Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal®
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 34ab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage®
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
a a , re Brick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Vintage® 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Elite GlassSeal®
Basic Wind Speed (V"it):
Max. 194 mph
(Frederick, Joplin &
Basic Wind Speed (Vag):
Max. 150 mph
Tuscaloosa)
Deck (HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass -Seal
new construction; Min. 15132 in. plywood existing
(Frederick, Joplin (Non-
construction.
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 16/32 in, plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment:
In accordance with FBC requirements.
Min, slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when Installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nall Pattern" detailed
below.
\nstallation
(Non-HVHZ):
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
."
Figure 1. Elite G
4 Nail Pattern
Butt Edge
Glass -Seal
� only)
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
1411- l
5.1/8"
6.7/8'r
5.118"
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TAMKO BUILDING PRODUCTS
yyt
Asphalt Shingles
N
t TECHNICAL SERVICES, LLC
Heritage®
Basic Wind Speed (Vut):
Max. 194 mph
(Dallas, Frederick, Joplin,
Basic Wind Speed (V," ):
Max. 150 mph
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage® Premium
new construction; Min. 15/32 in. plywood existing
(Dallas, Frederick
construction.
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 15/32 in. plywood or wood plank for
HeritageO Woodgate
new construction; Min. 7/16 in. OSB existing construction.
(Dallas & Frederick)
Undedayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ):
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
3. Heritage@, Heritage@ Premium,
4 Nail Pattern (non.
FASTENERS
i" I-T-1/2"►0-
NAIL ZONE
BOND
EXPOSU RE 5-6/8"
NAIL ZONE
COMMON
BOND
EXPOSURE 5-5/8"
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.4 FL18355-R4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall n
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes
specifically addressed herein.
i4of 11
CREEK
is valid.
are not
CREEK
TECHNICAL SERVICES, LLC
PAINT
7-718"
6-118"
TAMKO BUILDING PRODUCTS
Asphalt Shingles
NAIL ZONE/
COMMON BOND
- T
EXPOSURE 5 5/8"
/2'I►�7.3/8�7-1/2�7.1l2+I►I �-1"
Figure 5. Heritage@ Woodgate
6 Nail Pattern
FASTENERS
Figure 6. Heritage@, Heritage@
Alternate 6
DO NOT FASTEN
ALONG EDGE OF
COMMON BOND
PREFERRED
FASTENER
LOCATION
12.1
El Common Bond
8 Heritage@ Woodgate
ZONE
Figure 7. Heritage@ (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
"rt TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (V�it):
(Frederick) Basic Wind Speed (V,,):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
(Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in, plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application Instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE!
COMMON BOND
5"
12"
Figure 8. Heritage®
4 Nail Pattern (,
11 "--►� Imo_ _ i n
(Frederiicckk)
V only)
5"
1 �� �91h�—'1'9'I'— 9"---►�3L►�--9Va" IF-1
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
ZONE/
NON BOND
IbH1buur.4 FL18355-R4 i
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall n,
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes
specifically addressed herein.
,6 of 11
CREEK
is valid.
are not
CREEKr
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (V"u):
(Frederick) Basic Wind Speed (V,,):
Deck (Non-HVHZ):
5-112
1" 1
Underlayment:
Min. slope:
Installation (Non-HVHZ):
Figure 10. 1-
4 Nail
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
BOND
r---1 T
EXPOSURE 5"
f
iin � �in
® Woodgate (Frederick)
(non-HVHZ only)
BOND
1 T
5'1t/7' IXPOBURE 5"
S r �t
1"-- �- 9-1/2" -q4-3'+-93l8"43+ 9-1/2" -X �11--1"
Figure 11. Heritage® Woodgate
6 Nail Pattern
FL18355-R4
7 of 11
i nis evamanon report Is prowaea Tor State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKrdi
i TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (Vvil):
(Phillipsburg) Basic Wind Speed (V,sd):
Deck(HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in, plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
uwsm
, No%h
Figure 12. Heritage® Vintage®
5 Nail Pattern (n -HVHZ only)
Figure 13. Heritage® Vintage
6 Nall Pattern
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vml):
(Frederick & Joplin) Basic Wind Speed (V,,d):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. DEB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturers published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
exposure
Figure 1
Ian 1
1' Fastener
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
)xposure
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
LAO TECHNICAL SERVICES, LLC
Vintage@ Hip & Ridge Basic Wind Speed (V,u):
(Philkpsburg) Basic Wind Speed (Vag):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Direction of
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
wind
Figure a-- exposure
Fasten_ er
Figure 2 lr4 Figure 3
Figure 15. Vintage@ Hip & Ridge (Phil) sl urg)
FL18355-R4
10 Of
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODUCTS
1 Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E.
have demonstrated compliance with the Florida Building
Code, 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R.
r'oR�F���i
.`�,`G�P�G E N.
s: •��
2017.09.25
No 74021
11:31:41
_
-04'00'
%53 . STATE OF
, XN '.A14 0 P.�
Zachary R. Priest, P.E.
l�sSj0NM-
OganiationNoFlorida .ANE11669on No. 1
%%`%,,
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest In any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.