Loading...
HomeMy WebLinkAboutPRODUCT REPORTBILE COPY �Pr.. SCANNED 2160 SW Poma Drive BY Palm City, FL 34990 St. Lucie County _ (772)872-8034 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications CONCEALED FASTENERS ORATTACHyErNTS ARE THE RESPONSIBILTTY OF THE CONTRACTOR OR RECORD Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ OA2 specific gravity with 16" Coverage (Max.) Rib Height 1" RECEIVED 1UN"2 9 1010 Permitting Department St. Lucie County Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 FILE COPY Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads METHOD 1 I METHOD 2 DESIGN PRESSURE* 46 PSF Mainfield -97.25 PSF Perimeter _ FASTENER SPACING 6" O.C. 6" O.C. SEAM ADHESIVE Not required 3/16" continuous bead Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL S80-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY. • UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safety 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial `q;pNftIrrggyrcompani under this evaluation. ••••' (�• B�yV:l. Locke Bowden, P.E. Is not owned, operated, or controlle ►y mqy dianplo,c� t repo ��-2L�c ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCES : _Q o ••� REVIEWFri B i % �� •� STATE Of o� DATE PLANS A PER IT MUST BE K N ]OB �gO`ccN SITE OR NO INSPECTION(S) BE MADE°�rJ/ONAL Eu s• manufacturing or distributing products or distributing products under this II' seal THESE PLANS AND ALL PROPOSED WORK REQUIRED BY FIELD INSPECTORS THAT ORDERMAY BE NECESSARY IN TO COMPLY WITH ALL APPLICABLE CODES. Limitations: 1. Undedayment to be compliance with current Florida Building Code (FBC)2017 6'"ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 61^ ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wfjudsdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report 6. Support framing in compliance w/FBC 2017 61' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" Panel Profile 16' O.C. —T_ 3/4" —1 Deck: -15/32" or greater Plywood, or -Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) V FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details -15/3Z' or greater Plywood, or -Wood plank Factanar Isometric View rur meusuu c Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange (Refer to Table W)