THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ST2LkcT"a4 L
ST. LUCIE COUNTY BUILDING D ISION
REPLACE DOOR IN 1 OPENING ONLY. REVIEWED FOR COMPLIANCE AiD�
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED
SITE OR NO
MUST
BE MADE
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO. WIDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 1 36 1 80
20.00
4
46.5 1 -54.2
FL16708.1
65.0 1 -66.0
1 FRONT ENTRY - LSMI
CCNCEAIED FASTENEC:S OR A , ACHMn^Y i5
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 126 FT 5 IN FILE COPY
GOODMAN CONDO UNIT
9600 S. OCEAN DRIVE, UNIT 603
JENSEN BEACH, FLORIDA
DOOR REPLACEMENT PLAN