HomeMy WebLinkAboutWIND LOAD DESIGN PRESSURE CALCULATIONS'�� ENGINEERF �. EXPRESSo Order (Ref) #: 42482 (043270-4114467593) Contractor: J&G CARPENTRY, INC. Project Details: GOODMAN CONDO DOOR REPLACEMENT 9600 S OCEAN DRIVE, UNIT 603 7030 S.W. 16TH COURT PEMBROKE JENSEN BEACH, FL PINES, FL SCANNED BY Subject: Wind Load Design Pressure Calculations ( or ip&i%nt9ltPC)adding) Site Information Building Classification: enclosed Wind Speed (V It): 170 mph Exposure Category: c Roof Type: monoslope Roof Slope (0): 1.2 deg Mean Roof Height (h): 127.0 ft Min. Building Dimension (L): 94.0 ft Parapet_ 3 feet? No General Calculation Directionality Factor (Kd): 0.85 Gust -Effect Factor (G): 0.85 Internal Pressure Coefficient (GCp;): t 0.18 Topographical Factor (K,t): 1.0 Velocity Pressure Exposure Coefficient ( nK): 1.33 Velocity Pressure (qh): 83.70 psf End Zone (a): 9.4 ft ASD Method: P = 0.6w VI'Imms=®==M= M= NOTES: Design is in accordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017). Results are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. Results are based on contractor -supplied data and shall be field verified by others prior to use. Selection & installation Qf; products shall be approved using these dimensions and pressures as verified by others. Note: Far openings to be properly rated in Zone 4, no partof the opening shall be within 9.4 feet of any building corn: This engineer has not field visited this location and if this cannot be clearly identified by others, the opening shall be ® ; evaluated prior to Installation of any fenestration. All other information provided above Including mean roof heigTit building minimum dimensions, opening sizes,& other supporting data was provided by others. For definitions of tTie-l;( above terms, visit EngineeringExpress.com/Wiki" �i. )ca p�BAth aj�d Engineer �...... ST \DENSE o T 19 200� 82328 Luz ` 98 FLO P�.0• 160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442 42482(043270-4114467593) PHONE: (954) 354-0660 — FAX: (954) 354-0443 AutoPrint ENGINEERINGEXPRESS.COVI PAGE 1 OF 1