EVALUATION REPORT FLORIDA BUILDING CODE, C EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
(800)438-7465
www.owensoomfng.com SCANNED
ManufacturingLocation: Brentwood, NH BY
Houston, Tx St. Lucie County
Quality Assurance:
SCOPE
UL,LLC (QUA9625)
Category:..
.Roofing
Subcategory:
Undedayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Ent tv
PRI'Construction Matedals'Technologles
PRI Construction Materials Technologies
PRI_ Construction Materials Technologies
PRI Construction Materials Technologies
PRI Construction'Matedals Technologies
'PRI Construction. Materials Technologies
PRI Construction Materials Technologies
PRI Construction Materials Technologies
PRI Construction Matedals Technologies
PRI ConsWctionMatedals Technologies
PRI Construction Matedals Technologies
PRI Construction Materials Technologies
PRI Construction Materials Technologies
PRI Construction Materials Technologies
Report No.
NEI-039-02-01
NEI-042-02.01REV2
NEI-045-02-01
NEI-D45-02-01
NEI-053-02-01
NEI-053-02-01
NEI.093-02-02
OCF-213-02-01
OCF-237-02-01
OCF-252-02-01
OCF-252-02-01
OCF-253-02-02
OCF-272-02-01
OCF-296-02-02
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
PRI Construction Matedals Technologies (TST5878)
OCF-318-02-01
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
PRI Construction Materials Technologies (TST5878)
OCF-322-02.01
PRI Construction Materials Technologies (TST5878),
'Determined
OCF-355.02-01
to be equivalent to: ASTM D226-09, Type I
and II
Standard
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
TAS 103
ASTM G 166
ASTM D 1970
ASTM'D 1623
UL 1897
ASTM D 4798
.ASTM D.1970
ASTM D1970
TAS 103
ICQES AC 188'
ICC-ES AC 48
ASTM D 1970
ASTM D 1470
TAS 103
ASTM G 155
ASTM D 1623
UL 1897
UL 1897
Year
2015
2015
1995
2005a
1995
2005a
2015
2009
2012
2001
2015
2015
1995
2012
2012
2015
2015
1995
2005a
2009
2012
2012
This evaluation report Is provided for State of Florida productapproval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changesthroughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice.& Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock® G
WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-11 x 66.7-ft.
WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing•covedngs. Exposure on theroof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
WeatherLock® Mat is an ASTM D 1910 self-adhesive undedayment constructed from
(Brentwood NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, 77Q
sq. rolls with nominal dimensions of 3-ftx 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
Weatherl-ock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-f .
WeatherLodt® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock®
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive undedayment
Specialty Tile.& Metal
constructed from SBS modified asphalt. and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is. supplied in 2.14 sq. rolls with nominal dimensions of 3-ftx 71:3-11.
Houston, 7X)
WeatherLock9 Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered day or concrete file roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants„ Inc.) or TILE BOND'"' Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with day or concrete file installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
WeatherLock® G (High Tear) is a self -adhered, undedayment used as an alternative to
Tear),
ASTM D 226, Type I'or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, 7X)
modified bitumen undedayment The undedayment is composed.of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
produd is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with,nominal
dimensions of 3-ft x 65-ft
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited. to a maximum 30 days.
OCR14002.8a
r nis evawauon report Is provided. for State of Florida productapproval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. -
M
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock& SeN3ealing lee & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners, In the deck shall be checked forprobuslon and corrected prior to undedayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5minutes.
The'undedayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting at the save, and with minimum 3" side
laps and minimum 6" end: laps staggered min. 6-ft.from preceding course. Additionally,, if
applying WeatherLocM Specialty Tile & Metal, end laps shall be primed with. ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). Additionally, Weatherl.ockO Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when Installing at temperatures below the minimum
Temperature: application temperature.
=I .
The Maximum. Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Undedavment System No.1 — Weathert-ock Snecialty Tile & Metal Only
Roof Deck: Min. 15f32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga, x 1-5/6-inch 0 -tin caps spaced 12" o.c: The applied
undedayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a
rme evawauon report is promaed for State of Florida product approval under Rule 61 G20.3, The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express not imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self-sealing fee & Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The undedayment may be used as described in other current FBC product approval documents.
6) Design wind load pressures shall be determined for components and cladding In accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance. program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, RE: have demonstrated compliance with the Florida Building
Code a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
2017.10.
No 74021
09:06:29
*c
'
��
r r
—04 00
STATE OF
C.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641'
'CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest In any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturingor distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a.financial interest in any other entity involved in the approval process of the
product
END OF REPORT
of 4
r ms evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shag notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the'duration for which this report is valid.
Thisevaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein..
" z Q ti EXTERIOR RESEARCH & DESIGN, LLC.
`JGGOu�y Certificate of Authorization#9503
TRINITY ERD, ���,VG\e 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
i2nat 267A745
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-R13
Toledo, OH 43659 Date of Issuance:02/06/2012
(740) 404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the state of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for -compliance with the a Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: 'Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time .as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report Is displayed, then It shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report.shail be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida RegistratlonNo. 59166, Florida Dr-4ANE1983
The facsimile seal appearing ms authorized by Robert
Nieminen, P.E. on 10/09/2017. This does notserve w an
electronically signed dowmenL
CERMCATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3.. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the.
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
.project an which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained'
specifically for that purpose.
ROOFING: SYSTEMS EVALUATION:
1. SCOPE:
QOTRINITYIERD
Product Category: Roofing
Sub -Category: Asphalt.Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through. testing .in accordance with the following Standards. Compliance is.subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6,1
Wind Resistance
ASTM D3161
2616
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Entlity Examination
Reference
Date
UL LLC (CER9626) Physicals & Wind. Resistance
File R2453,.Vol. 3
02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC(TST9628) Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628) Wind Resistance
11C434308
02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC(TST9628) Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628) Physical Properties
Classification letter
02/13/2014
UL LLC OST9628) Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625) Quality Control
Service Confirmation
Exp..05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,
3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphaltroof
shingles.
4.1.3 Devonshir6m are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration., Duration
Premium Cool, TruDefinition
Duration Designer Color
Collection, TruDefinitionoOakridge, Oakridgee
and WeatherGuard HP are fiberglass, reinforced, laminated
asphalt roof shingles.
4.2 Hip &Ridge Shinales:
4.2.1 Berkshire' Hip & Ridge Shingles, High. Ridge, WeatherGuard HP Hip & Ridge Shingles, Pro Edge Hip & Ridge
Shingles and DuraRidgelm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips.
4.3.1 Starter Strip Shingle,'StarterStrip Plus and'StarterShingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
53 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specificallyfor that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ'jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report 037940.02.12•R8
eeWfrep6tofAuthoflrnnon000i 6' EDITION (2017)F9CNON-NVHZEVALUATION FL106741U.3
Owens Coming Asphalt Roof Shingles Revision 8: 10/0912017
Page 2 of
TR \, INI jY j ERD
1
5_4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7,1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are.acceptable
for use in all wind zones up to Vded = 150 mph (VI, = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vold = 150 mph (V;dt =194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualifieddesign professional are required for conditions
outside these limitations. Contact the shingle mariufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on windresistance andinstallation limitations.
5.5 All products in the roof assembly shall have.quality assurance audit in accordance with F.A.C. Rule 611320-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 611320-3, per FBC 1507.2.3,1507.2.4or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire"' shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 unitshorizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Fertander4ss"'rt Dark
ser,a,eied
Weaffiedoak-
on-
p edp
-"loaded
1'-1'6omeave
ffisw to�rt6�p ara�p adhesve
sstinstuoe=2 aao do'igaave
e "roared
SWtnStrip ekn4ie ovedua8i sanaud rakes 55 =$'
Exterior Research and Design, LLG Ewluatlon Report 037940dI2-12-118
cerofkare o)Authorhation#9503 6'"EDITION (Z017) FBC NON•HVHZ EVALUATION FL10674-R13
Owens coming Asphalt Roof Shingles Revision 8: 10/09/2027
Page 3 of 8
6.2.6 Minimum Nailing —Classic®&Supreme:
x� 'ad aw °'r
Ann. rxmmYo.n..
6.2.7 Minimum Nailing —Berkshire*:_
Standard Fastenine Pattern
air
15
Mansard or Steep Slope Fastening Pattern
----- PJNjTY ERD
Mansard or Arman p�
to
SNUM orip
IA ths do ubdw
,.1
&Nail Fastening Pattern
Exterior Research and. Design, U.C. Evaluation Report 037840.02.17 RB
COWImrcejAuftkarbn 89303 6'"EDITION '(2017('FBC NON-HVHZ EVALUATION FL30674R13
Owens Coming Asphah Roof Shingles Revision 8: 10/09/2017
Page 4 of 8
6.2.8 Minimum Nailing —Devonshire"':
mtr owsute
E"Attindx5418pull;
Fastenine Pattern
W
f TRINITY (ERD
mansara or Steep Slope Fastening Pattern
6.2:9 Minimum Nailing — Duration•, TruDeNnitionm Duration, Duration® Premium Cool & TruDeflnition'
Duration' Designer Color Collection:
Fastenino Gaftmn
_.Fateiilnataempsanmr7lranr:rz. -
*7'eF
wr ssr �
rmnMrorrpweeamge�i
Mansard or Steep Slope Fastening Pattern
6-Naii,Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report O37940.02.12-RS
CertlJknte OfAuthorhatlan 0950 6r"EDITION (2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8; 10/09/2017
Page 5 of 9
6.2.1 Minimum Nailing-TruDeflnition Oakridge°, OakridgeO:
41ULPiU m
Esgrratu ten..<chws,;
Standard Fastening Pattern
f. I RJNITY, ERD
_ -I
'6'NaOPAtero
ES9ft@l!l eon6Wws
+°
r
..,
66/0"Etpmrin
Ev➢oslrlw+d/6676Wd&�
CNNab 661a'. Eapowie
EW+rc6tnb 66/BNd@.
o-wan rastening Pattern
. _.__ _. FOb,iJnp Par alopgp Gnab,.iLai 2Lt@
b.waew�
�rYit+i
jl_^fl
IP
r� t!i,eNaspreeengieoim
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing— WeatherGuardO HP:
d
1` - - 7 IilRplstWllfbta
a -
Eaterfor Research and Design, I.I.C. Evaluation Report O37940.OL12•RS
Cernlrote ofAudor4ntbn2'9503 6'"EDITION (2017)FBC NON-NVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 6 of 8
PJNj.TY ERD
-_ 4
6_3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and PrDEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge' Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples arenot permitted..
6.3.3 Minimum Nailing — Berkshlree Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Exterior Research and Design, LLC. Evaluation Report 037940.02:12-Rli
C6-6ffmteofAuthorlmtion09M GPEDITION (2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles. Revision 8: 10/09/2017
Page 7 of 8
`,_ 1 K1N1Ti ERD
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
PMVOMng
Win✓d-OiroOdott Be" Sttfp
6' Expasm
Fades 7%' _
s
6.3.6 Minimum Nailing — DuraRldge" Hip& Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation Instructions for their minimum requirements.
�'-06sNwl� .�riret0a:d�wx
Dlndtrii dJ dm proda�ral�
P YfW+ojvubr
1
I.
CID
Egg
1.2
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt.shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 Oq
requirements.
10.. QUALITY ASSURANCE ENnTy:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -