Loading...
HomeMy WebLinkAboutMISC LETTERRICHA"SON ENGINEERING 131 Zelma Street Orlando, Florida 32803 LIC#00012380 / ID# EB 26251 407-425-4002 / Fax # 407-841-7932 rengacct a,bellsouth net July 12, 2018 FILE Copy Tami Hanson 321-313-1779 tami@myaffordableroof.com SGANNE� 5t. Luce GOuntY RE: Two Story Residential Building at 5779 Deer Run, Fort Pierce, FL 34951 Dear Ms. Hanson: This letter is to confirm that we have completed our analysis of the applied wind pressures to the roof of the above referenced project, Our analysis is based on the Florida Building Code 2017, 61h Ed, referencing ASCE 7 —10. The wind velocity is 170 mph, risk category II, exposure B, GCpi = +.18,-.18, and the pressures are compatible with allowable stress design. (Ultimate pressures can be obtained by dividing the given pressures by 0.6). Pressure at comers: -73.20 psf Pressure at roof edges: -53.74 psf Pressure at interior zone:-34.2 psf Please call if we can be of any further assistance. Sincerely, Cr Felix Crommie g Richardqlrdsaonj 180471 Digitally signed by Richard t Richardson �.��,k�yo ,.: Reason: This item has been ,, `4`\*`,',P�`B•�A k\ electronically sealed using a SHA-1 authentication code. Printed copies ' 0 4this document are not considered %90�00•,.°'•"-'! WW s, signed and sealed and the SHA-1 : ", syr+°-'%*,Z,.• F— autheiil6tlori code must be verified on electronic �oples. Date: 2018.07.12 15:35:27 -04'00'