Loading...
HomeMy WebLinkAboutNOASCANNED BY St. Lucie County MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv CertainTeed Corporation 20 Moores Malvern, PA 19355 FILE COPY CONCEALEDARECONTRACTOR TTHERE"ISPO ORR ORDTHE�S SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. Th6 documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Buildin&ff� COUNTI BU G DIVISI!)gW This NOA renews NOA #14-0529.02 and consists of pages 1 through 42. REVIEWED FBOR I tC The submitted documentation was reviewed by Alex Tigera. DATE PLAN AND -PERMIT MUST BE KEPT ON JOB SITE OR NO INSP CTI N(S) WILL BE MADE ML4MI-DADE COUNTY OA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 THESE PLANS AND A PROPOSED WORK Page I of 42 ARE SUBJECT TO AN CORRECTIONS REQUIRED BY FIW) INSPECTORS THAT MAY ®E N9CF99ARY IN 17Rncm rn ROOFING SYSTEM APPROVAL Cateaorv: Roofing Sub-Cateeorv: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum DesiLm Pressure: -127.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 39 3/s" x 65' 10"; ASTM D 4601, Type Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. II base sheet. (2 squares) UL Type G2 Flexiglas Base Sheet 39 3/8" x 98'9'; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet. (3 squares) UL Type G2 Flintlastic Base 20 39 3/8" x 49' 6"; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintglas Ply Sheet Type IV 39 3/8" x 164'7'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet. weight: 381bs. IV (5 squares) UL Type Gl Flintglas Premium Ply Sheet 39 3/8" x 164'7'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply Type VI weight: 40 lbs. VI sheet. (5 squares) UL Type GI Flintlastic STA 39 3/8" x 32' 10'; Roll ASTM D 6222, Smooth surfaced APP Modified weight: 871bs. Grade S, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/8" x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/s" x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/a" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 2 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 ' Test Product Product Dimensions Specification Description Flintlastic FR-P 39 3/81, x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39'/s' x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight:101 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic FR Dual Cap 39 %" x 32' 10'; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 lbs. Grade G, Type I bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Flintlastic FR Cap 30 39 3/s" x 32' 10'; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 86 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T 39-318" x 32' 10'; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 100 lbs. Grade G, Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic Base 20 T 39-3/8" x 33'; Roll ASTM D 6163, Modified Bitumen, coated fiberglass Weight: 81 lbs. Grade S, Type I base sheet for torch application. (1 square) Flintlastic FR Cap 30 CoolStar 39 'Is" x 32' 10' ; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 88 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic FR Cap 30 T 39 3/8" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS CoolStar weight: 102 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic GTA CoolStar 39 3/8" x 32' 10'; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 3 of 42 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic GTA-FR CoolStar 39 3/s" x 32' 10'; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS CoolStar 39 3/s" x 3T 10' ; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 97 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic FR-P CoolStar 39 ;/8" x 32' 10' ; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium FR-P 39 3/8" x 32' 10' ; Roll ASTM D 6164, Fire resistant, granule surfaced SBS CoolStar weight: 103 lbs. Grade G, Type II Modified Bitumen Membrane with (I square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Ultra Poly SMS 39 3/8' x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. (1 Grade S, Type I Bitumen Membrane with non -woven squares) polyester mat reinforcement for mop applications. Glasbase Base Sheet 36" x 98' 9'; Roll ASTM D 4601, Type Asphalt coated, fiberglass base sheet. weight: 75 lbs. II, (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/s" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type II base sheet. (2 squares) UL Type G2 Yosemite Venting Base Sheet 39 3/s" x 32' 10' ; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897, Type buffer sheet. (1 square) II UL Type G3 Flintlastic APP Base T 39 3/8" x 65' 4'; Roll ASTM D 6509 Modified Bitumen coated fiberglass weight: 100 lbs. base sheet. (2 squares) NOA No.:17-1003.04 MIAMFD=ECOUNW Expiration Date: 06/1923 Approval Date: 04/19/18 Page 4 of 42 Flintlastic Ultra Glass SA Black DiamondTM Base Sheet APPROVED INSULATIONS: Product Name F1intBoard ISO FlintBoardx ISO ACFoam -II DensDeck DensDeck Prime 39 3/8" x 33' 11' ; Roll weight: 73 lbs. (1 square) 36" x 687'; Roll weight: 78 lbs. (2 squares) ASTM D 1970 ASTM D 1970 TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Water resistant gypsum board H-Shield Polyisocyanurate foam insulation ENRGY 3 Polyisocyanurate foam insulation ENRGY 3 25 PSI Polyisocyanurate foam insulation Multi -Max FA-3 Polyisocyanurate foam insulation SECUROCK Gypsum -Fiber Roof Board homogenous fiber reinforced Structodek High Density Fiberboard Roof Insulation High Density Wood Fiber Insulation board Self -adhering, fiberglass reinforced, SBS modified bitumen baselply sheet. Self -adhering fiberglass reinforced modified bitumen base sheet Manufacturer (With CurrentNOA) CertainTeed Corporation CertainTeed Corp. Atlas Roofing Corp. Georgia Pacific Gypsum LLC Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. Johns Manville Corp. RMax Operating, LLC USG Corp. Blue Ridge Fiberboard, Inc. FescoBoard Expanded perlite and fiber insulation Johns Manville Corp. NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 5 of 42 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With CurrentNOA) 1. Trufast # 12 DP Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. 2. Trufast 3" Metal Galvalume steel plate 3" round Altenloh, Brinch & Co. U.S., Insulation Plate Inc. 3. FlintFast #12 Coated, carbon steel screw various CertainTeed Corp. 4. F1intFast 3" Insulation Galvalume AZ50 steel plate 3" round CertainTeed Corp. Plate 5. F1intFast #14 Insulation fastener for wood various CertainTeed Corp. and steel decks 6. Simplex MAXX Cap Polymer fastner I" long Simplex Nails, Inc. 7. OMG #12 Standard Insulation fastener for wood various OMG, Inc. Roofgrip and steel. 8. OMG 3" Galvalume Steel Galvalume stress plate 3" round OMG, Inc. Plate 9. Trufast #14 HD Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. 10. OMG Heavy Duty Insulation and membrane Various OMG, Inc. fastener 11. 3 in. Round Metal Plate Galvalume AZ50 steel plate 3" round OMG, Inc. 12. AccutTrac Hextra Carbon steel fastener Various OMG, Inc. 13. AccuTrac Plate Galvalume stress plate. 3" square OMG, Inc. 14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3" square OMG, Inc. Plate 15. Millennium One Step Polyurethane two component 1.5 liters Adco Products, Inc. d.b.a. Foamable Adhesive high rise insulation adhesive Royal Adhesives & Sealants, Inc. 16. Millennium PG-1 Low Polyurethane two component 1.5 liters Adco Products, Inc. d.b.a. Viscosity Insulation low rise insulation adhesive Royal Adhesives & Sealants, Adhesive Inc. 17. Insta Stik Quik Set Polyurethane one component It is supplied The Dow Chemical Company Insulation moisture curing adhesive in pressurized cylinders with a net weight of 23 lbs., with a total unit weight of 30 lbs. NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 6 of 42 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 18. OMG OlyBond 500 Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge 19. OMG OlyBond 500 Green Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 400 Ibs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gaUsq. 4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 17-1003.04 Expiration Date: 06/19f23 Approval Date: 04/19/18 Page 7 of 42 EVIDENCE SUBMITTED: Test Agency/identifier Name Report Date Factory Mutual Research Corp. FM 4470 3Y8A1.AM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 2DOAO.AM 12/23/98 FM 4470 ID7A4.AM 11/09/98 FM 4470 3039046 06/15/10 FN4 4470 3048520 09/19/13 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 Momentum Technologies, Inc. ASTM D6164 AX3108F 06/05/09 TrinitylERD TAS 114(J) 3507.08.99-1 04118/01 TAS 114(J) 3504.06.01-1 06/05/01 TAS 114 3521.07.04 07/29/04 TAS 114 3533.01.06 01/06/06 TAS 114" Letter 04/05/06 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 117 (B)/ ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 FM 4470, TAS 114, FM 4470, C8370.08.08-R1 10/05/09 TAS 114(J) ASTM Physical Properties C10080.09.08-R4 03/25/10 TAS 114(H), TAS 117(B), TAS C30560.06.10 6/10/10 114(J) FM 4470, TAS 114 C32830.07.10 7/20/10 ASTM D6164/134798 C31410.01.11-2 01/10/11 TAS 117B C35500.02.11 02/09/11 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1876 C35460.05.11 06/16/11 ASTM D1876, TAS 114 (H), C42110.08.12 08/13/12 TAS 117 (B) FM 4474/TAS 114 C39670.08.12 08/20/12 ASTMD1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R1 11/01/12 ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12 ASTMD4798 C31410.01.11-2A-Rl 02/21/13 ASTM D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13-R1 12/31/13 TAS 117, TAS 114 C30310.12.09-R1 03/07/14 ASTM D1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 ASTM D 1876, TAS 114 (H), C47320.03.14-R1 04/01/15 FM 4474 NOA No.: 17-1003.04 MLAMMAuecounrtv Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 8 of 42 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date ASTM D4601-04 (2012), Type II CTR-SC11145.09.16- 09/19/16 3A PRI Construction Materials ASTM D6163 CTC-066-02-01 08/09/11 Technologies LLC ASTM D6222 CTC-071-02-01 08/08/11 ASTM D6222 CTC-070-02-01 08/09/11 ASTM D6164/134798 CTC-093-02-01 08/09/11 ASTMD4601 CTC-126-02-01 03/12/12 ASTM D2178 CTC-122=02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTMD4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTMD1970 CTC-199-02-01 01/22/14 ASTM D6163 CTC 319-02-01 08/22/17 NOA No.: 17-1003.04 MAMMAD; COUNTY Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 9 of 42 APPROVED ASSEMBLIES: Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 19132 " or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at woodjoists spaced maximum 24" o.c. System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener able 3 Density/ft2 ACFoam-II, Multi -Max FA-3, ENRGY 3, FlintBoard ISO, H-Shield Minimum 1.511 thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installedas the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet, (Optional) Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered. Or One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar torch adhered to base or ply sheet. NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 10 of 42 Surfacing: (Optional) Maximum Design Pressure: Any of the approved surfacing/coating options listed in Table 4. -52.5 psf (See General Limitation #7) NOA No.: 17-1003.04 MAMWADE COUMiY Expiration Date: WOW Approval Date: 04/19/18 Page 11 of 42 Membrane Type: Deck Type 1I: Deck Description: System Type A(2): SBS Modified All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexi as Base e 2 oasticPoly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Shee Glasbase Base Sheet r Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener able 3 Density/ff ACFoa_m-II ENR , ENRGY 3 25 PSI, FlintBoard ISO, H-Shield, FlintBoardu IS 'uim m•LS",,thick' N/A N/A FescoBoard Minimum'/4" thick N/A N/A Structodek i h Denai Fiberboard `oati nimrm',x"'thick N/A N/A DensDeck, DensDeck Prime Minimum'/" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq MUIMFMDE COUNTY NOA No.: 17-1003.04 �Lw• • , Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 12 of 42 Ply Sheet: ie ly of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Optional) lintiastie Base 20 lintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type 1V or Flintglas Premium Ply Sheet Type VI adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self - adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. Membrane: Qne 1 a Flintlastic GMS lintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR P, Flintlastic R- o5lStar, Flintlastic Premium FR-P, Flintlastic Premium FR P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet :with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bsJsq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply sheet. Surfacing: (Optional) Maximum Design Pressure: MIAWDADECOUNTY Any of the approved surfacing/coating options listed in Table 4. -52.5 psf (See General Limitation #7) NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 13 of 42 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o. c. System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and Systern,Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet; Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations Insulation Laver Insulation Fasteners Fastener able 3 Densi /ft2 ACFoam-H, Multi -Max FA-3, ENRGY 3, FlintBoard ISO, H-Shield Minimum 1.5" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation 47) Pressure: NOA No.: 17-1003.04 MIAMMADE COUNTY Expiration Date: 06/1923 Approval Date: 04/19/18 Page 14 of 42 Membrane Type: Deck Type 1I: SBS Modified Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o. c. System Type A(4): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flin0astic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Table 3 ACFoam-II, ENRGY 3, ENRGY 3 25 PSI, FlintBoard ISO, H-Shield, FlintBoardH ISO Minimum 1.5" thick N/A Fastener Density/ff N/A FescoBoard Minimum %11 thick N/A N/A Structodek High Density Fiberboard Roof Insulation Minimum %" thick N/A N/A DensDeck, DensDeck Prime Minimum'/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 15 of 42' Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic; Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 C6olStar adhered to base/ply sheet with approved mopping asphalt applied within.the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation #7) Pressure: NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 16 of 42 Membrane Type: Deck Type 1I: APP Modified Wood, Insulated Deck Description: 15/32" or greater CDX plywood or wood plan attached with #8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System TypeB(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener able 3 Density/ft= FlintBoard ISO, ACFoam-II, H-Shield, FlintBoardn ISO Minimum 1.5" thick 1 or 3 1:1.33 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Too Insulation Laver Insulation Fasteners Fastener able 3 Density/ft= FlintBoard ISO, ACFoam-II, B-Shield, FlintBoarda ISO Minimum 1.5" thick N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG- 1 Low Viscosity Insulation Adhesive in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered. Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4 (Optional) Maximum Design -67.5 psf (See General Limitation #7.) Pressure: NOA No.: 17-1003.04 ML4M4W, LINTY Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 17 of 42 Membrane Type: APP Modified Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced" 6" o.c. at wood joists spaced maximum W' o.c. System Type B(2): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener able 3 Density/fti FlintBoard ISO, ACFoam-II, H-Shield, FlintBoardn ISO Minimum 1.5" thick 1 or 3 1A.33 Note: Base layer shall be, mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application, Standard RAS 117 for fastening details). Too Insulation Laver SECUROCK Gypsum -Fiber Roof Board Minimum 11411 thick Insulation Fasteners Fastener able 3 Density/fe N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG- 1 Low Viscosity Insulation Adhesive, Insta-Stik Quik Set Insulation Adhesive, OMG OlyBond 500 or OMG OlyBond 500 Green Adhesive in 3/4" —1" wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. (Optional) Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -90 psf (See General Limitation #7.) Pressure: NOA No.:17-1003.04 MLAMMME COUNTY Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 18 of 42 Membrane Type: Deck Type 1I: Deck Description: APP Modified Wood, Insulated 15/32° or greater CDX plywood or wood plank attached with#8 screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type C(1): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners able 3 FlintBoard ISO, ACFoam-H, H-Shield, FlintBoardu ISO Minimum 1.5" thick N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Ton Insulation Laver Insulation Fasteners able 3 SECUROCK Gypsum -Fiber Roof Board Minimum 1/4" thick 1 or 3 Fastener Density/ftt N/A Fastener Density/ft2 1:1.33 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Ply Sheet: (Optional) Membrane: Surfacing: (Optional) Maximum Design Pressure: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Any of the approved surfacing/coating options listed in Table 4. -67.5 psf (See General Limitation #7.) NOA No.: 17-1003.04 MIAM4DAD; COUNTY Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 19 of 42 Membrane Type: APP Modified Deck Type 1I Wood, Insulated Deck Description: 15/32" or greater C6X plywood or wood plank attached with #8 screws spaced 6" o.c. at wood joists spaced maximum'24" o.c. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation'I aver Insulation: Fasteners Fastener able 3 Density/ftx FlintBoard.ISO, ACFoam-H, HShield,°Flintl3oat de ISO Minimum 1.5" thick N/A N/A Note: All layers shall be_simultaneously fastened; see top layer below for fasteners and density. Top Insulation Laver Insulation. Fasteners Fastener Table 3 Deusity/ft2 FlintBoard ISO, ACFoam-H; H-Shield, FlintBoard6ISO Minimum 1.5" thick 1 or 3 1.1.33 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and, dimensions; if larger panels are used, the number. of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One•ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. Ply Sheet: One or more plies of Flintlastic APP Base T or-Flintlastic STA,-torch adhered. Membrane: One ply of Flintlastic GTA, FlintlasficGTA CoolStar, Flintlastic GTA=FR or ElintlasticGTA- FR CoolStar, torch adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75.0 psf (See General Limitation #7.) Pressure: NOA No.i 17-1003.04 MLAMMADEGOUNTII. Expiration Date' 06/19/23, Approval Date: .04/19/18:, Page 20. of 42 . Membrane Type: SBS Modified Deck Type 1: Wood, Non -insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank mails spaced 6" ox at wood joists spaced maximum 24" o.c. System Type E(I): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather /'Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base. Sheet mechanically attached as detailed below. Fastening: Fastened with SimplexMAXX Cap fasteners spaced '9",o.c. in,the2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR- P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved mopping asphalt applied within. the',EVT range and at a rate of 20-40 Ibs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Surfacing: Any of the approved surfacing/coafmg options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation #9) Pressure: NOA No.: 17-1003.04 MIAMFDADECOUNTr Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 21 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non -insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum o.c. System.Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below. Fastening: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR P, Flintlastic FR P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR- P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf (See General Limitation 49) Pressure: MIAMFDADE COUN7Y NOA No.: 17-1003:04 . • • • � � Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 22 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in;the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar torch adhered to basdply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page'23 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(4): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Mintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 24 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8d ring shank nails spaced 6" o.c. at wood joists spaced 24" o.c. System Type E(5): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as described below. Fastening: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bsJsq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: MIAM4DADE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 25 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non-hisulated Deck Description: 1 9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at wood joists spaced maximum 24" o. c System Type E(6): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar torch adhered to base/ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation #7) Pressure: MiAMMADE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 26 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 1 9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c, at wood joists spaced maximum 24" o. c System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with I 1 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf. (See General Limitation #7) Pressure: MIAMFOADE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 27 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or -greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced at maximum 24" o.c. System Type E(8): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet orFlintlastic Ultra Poly SMS Base Sheet, mechanically attached asdescribed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8" o.c, at the 3" lap and 8" o.c. in three, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -60 psf (See General Limitation #7.) Pressure: MIAMMADE COUNTY NOA No.:17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18' Page 28 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(9): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Glasliase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SM&Base Sheet, mechanically attached as•described below. Fastening: Anchor sheet shall be fastened with FBC RYHZ nails and tin caps spaced 8" o.c. at the 3" lap and 8" o.c. in three, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (optional) Maximum -Design -60 psf (See General Limitation #7.) Pressure: MUUIFnADE COUNTY NOA No.: 17-1003.04 . • • . , , Expiration Date: 06/19/23 Approval Date: 04119/18' Page 29'of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(10): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Glasbase-Base Sheet, Yosemite Venting Base Sheet Flexiglas Base Sheet, Flintlastic Base 20, Flintlastiq Poly SMS Base Sheet of Flintlastic Ultra Poly SMS Base , Sheet, mechanically attached asdescribed below. Fastening: OMG #12 Standard Roofgrip fasteners with OMG 3" Galvanized Steel Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or Flintfast #12 fasteners with Flintfast 3" plates spaced 7" o.c. at the 4" wide laps and 7" o.c. in two, equally spaced staggered center rows. Ply Sheet: One ply of Flintlastic Ultra Glass SA, selfadhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -67.5 psf. (See General Limitation 47) Pressure: MIAMFDADE COUNTY NOA No.: 17-1003.04 � , • .. , , Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 30 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 11/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c.' at wood joists spaced maximum 24" o.c. System Type E(11): Base'sheet mechanically fastened All General and, SystemLimitations apply. Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Fli_mlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All-Weather/Empire Base Sheet, mechanically attached as described Below. Fastening: Anchor sheet shall be fastened with HVM nails and tin caps spaced 6" o.c. at the 3" lap and 6 o.c. in four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P,.Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T. CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf (See General Limitation #7.) Pressure: MIAM4nADECOUNTY NOA No.: 17-1003.04 • • • � � .Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 31 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(12): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One of more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All Weather/Empire Base Sheet, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 3 o.c. is four, equally spaced staggered center rows. Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -82.5 psf (See General Limitation #7.) Pressure: MIAMFDADE COUNTY NOA No.: 17-1003.04 , • • • � � Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 32 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/3z' or greater CDX plywood or wood plank attached with#10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(13): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic FR Cap 36, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, FlintlasticFR:P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -90 psf. (See General Limitation#9) Pressure: NOA No.: 17-1003.04 nwnFoanecourrry Expiration Date: 06/19/23 Approval Date: 04/19/18' Page33 of 42 £3 Membrane Type: APP Modified, Deck Type 1: Wood, Non -Insulated =_ Deck Description: is/az" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6 o coat wood joists spaced r` J P maximum 24" o.c. System Type E(14): Base sheet mechanically fastened. 4 1 ,,- All General and System Limitations apply. sx a: _s Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the cent"' of the sheet. Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA F CoolStar, torch -applied as Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) 94 Maximum Design -90 psf. (See General Limitation #4) } Pressure: xu =v55 LPr APPROVED NOA No.: Expiration Dad Approval Dad Page 34 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(15): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheetmechanically attached as described -below. Fastening: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal 'Plates; ' OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, F1intFast #12 or F1intFast # 14 fasteners with F1intFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in three, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq. or one or more plies of Flintlastic Base 20 T or Flindastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic G.MS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR. P,, Flintlastic FR P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Opti(nal) Maximum Design -97.5 psf. (See General Limitation #7) Pressure: MU1MFnADE COUNOA No.: 17-1603.04 N7'r ... , , Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 35 of 42 Membrane Type: SBS Modified Deck Type 1I: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type E(16): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divined, staggered rows in the center of the sheet. Ply Sheet: None Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf. (See General Limitation #9) Pressure: MIAMFnf1DE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 36 of 42 Membrane Type: APP Modified Deck Type 1I: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4"o.c. at wood joists spaced maximum 24" o.c. System Type E(17): Base sheet mechanically fastened. All General and System Limitations apply. Base Skeet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and'6" o.c. in three evenly divided, staggered rows in the center of the sheet. Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar, torch -applied Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf. (See General Limitation 49) Pressure: NOA No.: 17-1003.04 MIAM4DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 37 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: "/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(18): Base sheet mechanically fastened All General and System Limitations apply. Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening: Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or FlintFast #12 Fasteners with F1imFast 3" Insulation Plates spaced 7" o.c. at the 4" lap and 7 o.c. in three, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105.0 psf (See General Limitation #7.) Pressure: NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 38 of 42 Membrane Type: SBS Modified Deck Type 1: Wood, Non -Insulated Deck Description: 19132" or greater plywood or wood plank attached with 48 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(19): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid (Optional) Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and 4" o.c. in four, equally spaced center rows. Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf (See General Limitation #7.) Pressure: ML4MFOADE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 39 of 42 Membrane Type: APP Modified Deck Type 1: Wood, Non -Insulated Deck Description: 11/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood joists spaced maximum 24" o.c. System Type E(20): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid (Optional) Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and 4" o.c. in four, equally spaced center rows Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered. Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Ftintiastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -105 psf (See General Limitation P.) Pressure: NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 40 of 42 Membrane Type: SBS Modified Deck Type 1I: Wood, Non -Insulated Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at wood joists spaced maximum 24" o.c. System Type. E(21): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as described below. Fastening: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, FlintFast # 12 or F1imFast # 14 fasteners with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Ftintlastic FR- P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -127.5 psf. (See General Limitation #7) Pressure: MWMFnADEt.OUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: o4/19/18 Page 41 of 42 WOOD DECK SYSTEM LIMITATIONS: I. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq, or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MUIM4MDE COUNTY NOA No.: 17-1003.04 Expiration Date: 06/19/23 Approval Date: 04/19/18 Page 42 of 42