HomeMy WebLinkAboutNOASCANNED
BY
St. Lucie County
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
CertainTeed Corporation
20 Moores
Malvern, PA 19355 FILE COPY CONCEALEDARECONTRACTOR TTHERE"ISPO ORR ORDTHE�S
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. Th6
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Buildin&ff� COUNTI BU G DIVISI!)gW
This NOA renews NOA #14-0529.02 and consists of pages 1 through 42. REVIEWED FBOR I tC
The submitted documentation was reviewed by Alex Tigera. DATE
PLAN AND -PERMIT MUST BE KEPT ON JOB
SITE OR NO INSP CTI N(S) WILL BE MADE
ML4MI-DADE COUNTY OA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
THESE PLANS AND A PROPOSED WORK Page I of 42
ARE SUBJECT TO AN CORRECTIONS
REQUIRED BY FIW) INSPECTORS THAT
MAY ®E N9CF99ARY IN 17Rncm rn
ROOFING SYSTEM APPROVAL
Cateaorv:
Roofing
Sub-Cateeorv:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum DesiLm Pressure:
-127.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
All Weather/Empire Base
39 3/s" x 65' 10";
ASTM D 4601, Type Asphalt coated, fiberglass reinforced
Sheet
Roll weight: 70 lbs.
II
base sheet.
(2 squares)
UL Type G2
Flexiglas Base Sheet
39 3/8" x 98'9'; Roll
ASTM D 4601, Type Modified Bitumen coated fiberglass
weight: 90 lbs.
II
base sheet.
(3 squares)
UL Type G2
Flintlastic Base 20
39 3/8" x 49' 6"; Roll
ASTM D 6163,
Modified Bitumen coated fiberglass
weight: 90 lbs.
Grade S, Type I
base sheet.
(1.5 squares)
Flintglas Ply Sheet Type IV
39 3/8" x 164'7'; Roll
ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet.
weight: 381bs.
IV
(5 squares)
UL Type Gl
Flintglas Premium Ply Sheet
39 3/8" x 164'7'; Roll
ASTM D 2178, Type Fiberglass, asphalt impregnated ply
Type VI
weight: 40 lbs.
VI
sheet.
(5 squares)
UL Type GI
Flintlastic STA
39 3/8" x 32' 10'; Roll
ASTM D 6222,
Smooth surfaced APP Modified
weight: 871bs.
Grade S, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application.
Flintlastic GTA
39 3/8" x 32' 10' ; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application.
Flintlastic GTA-FR
39 3/s" x 32' 10' ; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application.
Flintlastic GMS
39 3/a" x 32' 10"; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 94 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application.
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 2 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1 '
Test
Product
Product
Dimensions
Specification
Description
Flintlastic FR-P
39 3/81, x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
39'/s' x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight:101 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap
39 %" x 32' 10'; Roll
ASTM D 6162,
Granule surfaced SBS modified
weight: 103 lbs.
Grade G, Type I
bitumen membrane with a nonwoven
(1 square)
polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic FR Cap 30
39 3/s" x 32' 10'; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 86 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T
39-318" x 32' 10'; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 100 lbs.
Grade G, Type I
Bitumen membrane with fiberglass
(1 square)
mat reinforcement for torch
application.
Flintlastic Base 20 T
39-3/8" x 33'; Roll
ASTM D 6163,
Modified Bitumen, coated fiberglass
Weight: 81 lbs.
Grade S, Type I
base sheet for torch application.
(1 square)
Flintlastic FR Cap 30 CoolStar
39 'Is" x 32' 10' ; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 88 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap 30 T
39 3/8" x 32' 10"; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
CoolStar
weight: 102 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic GTA CoolStar
39 3/8" x 32' 10'; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 3 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic GTA-FR CoolStar
39 3/s" x 32' 10'; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS CoolStar
39 3/s" x 3T 10' ; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 97 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P CoolStar
39 ;/8" x 32' 10' ; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 103 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Premium FR-P
39 3/8" x 32' 10' ; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
CoolStar
weight: 103 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(I square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Ultra Poly SMS
39 3/8' x 32' 10'; Roll
ASTM D 6164,
Smooth surfaced SBS Modified
Base Sheet
weight: 90 lbs. (1
Grade S, Type I
Bitumen Membrane with non -woven
squares)
polyester mat reinforcement for mop
applications.
Glasbase Base Sheet
36" x 98' 9'; Roll
ASTM D 4601, Type Asphalt coated, fiberglass base sheet.
weight: 75 lbs.
II,
(3 squares)
UL Type G2
Flintlastic Poly SMS Base
39 3/s" x 64' 3"; Roll
ASTM D 4601,
Modified Bitumen coated polyester
Sheet
weight: 90 lbs.
Grade S, Type II
base sheet.
(2 squares)
UL Type G2
Yosemite Venting Base Sheet
39 3/s" x 32' 10' ; Roll
ASTM D 3909
Mineral Surfaced fiberglass reinforced
weight: 85 lbs.
ASTM D 4897, Type buffer sheet.
(1 square)
II
UL Type G3
Flintlastic APP Base T
39 3/8" x 65' 4'; Roll
ASTM D 6509
Modified Bitumen coated fiberglass
weight: 100 lbs.
base sheet.
(2 squares)
NOA No.:17-1003.04
MIAMFD=ECOUNW
Expiration Date: 06/1923
Approval Date: 04/19/18
Page 4 of 42
Flintlastic Ultra Glass SA
Black DiamondTM Base Sheet
APPROVED INSULATIONS:
Product Name
F1intBoard ISO
FlintBoardx ISO
ACFoam -II
DensDeck
DensDeck Prime
39 3/8" x 33' 11' ; Roll
weight: 73 lbs.
(1 square)
36" x 687'; Roll
weight: 78 lbs.
(2 squares)
ASTM D 1970
ASTM D 1970
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Water resistant gypsum board
Water resistant gypsum board
H-Shield Polyisocyanurate foam insulation
ENRGY 3 Polyisocyanurate foam insulation
ENRGY 3 25 PSI Polyisocyanurate foam insulation
Multi -Max FA-3 Polyisocyanurate foam insulation
SECUROCK Gypsum -Fiber Roof Board homogenous fiber reinforced
Structodek High Density Fiberboard
Roof Insulation
High Density Wood Fiber Insulation
board
Self -adhering, fiberglass reinforced,
SBS modified bitumen baselply sheet.
Self -adhering fiberglass reinforced
modified bitumen base sheet
Manufacturer
(With CurrentNOA)
CertainTeed Corporation
CertainTeed Corp.
Atlas Roofing Corp.
Georgia Pacific Gypsum LLC
Georgia Pacific Gypsum LLC
Hunter Panels LLC
Johns Manville Corp.
Johns Manville Corp.
RMax Operating, LLC
USG Corp.
Blue Ridge Fiberboard, Inc.
FescoBoard Expanded perlite and fiber insulation Johns Manville Corp.
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 5 of 42
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With CurrentNOA)
1.
Trufast # 12 DP Fastener
Insulation fastener for wood
various
Altenloh, Brinch & Co. U.S.,
and steel decks
Inc.
2.
Trufast 3" Metal
Galvalume steel plate
3" round
Altenloh, Brinch & Co. U.S.,
Insulation Plate
Inc.
3.
FlintFast #12
Coated, carbon steel screw
various
CertainTeed Corp.
4.
F1intFast 3" Insulation
Galvalume AZ50 steel plate
3" round
CertainTeed Corp.
Plate
5.
F1intFast #14
Insulation fastener for wood
various
CertainTeed Corp.
and steel decks
6.
Simplex MAXX Cap
Polymer fastner
I" long
Simplex Nails, Inc.
7.
OMG #12 Standard
Insulation fastener for wood
various
OMG, Inc.
Roofgrip
and steel.
8.
OMG 3" Galvalume Steel
Galvalume stress plate
3" round
OMG, Inc.
Plate
9.
Trufast #14 HD Fastener
Insulation fastener for wood
various
Altenloh, Brinch & Co. U.S.,
and steel decks
Inc.
10.
OMG Heavy Duty
Insulation and membrane
Various
OMG, Inc.
fastener
11.
3 in. Round Metal Plate
Galvalume AZ50 steel plate
3" round
OMG, Inc.
12.
AccutTrac Hextra
Carbon steel fastener
Various
OMG, Inc.
13.
AccuTrac Plate
Galvalume stress plate.
3" square
OMG, Inc.
14.
AccuTrac Flat Bottom
A2-SS aluminized steel plate
3" square
OMG, Inc.
Plate
15.
Millennium One Step
Polyurethane two component
1.5 liters
Adco Products, Inc. d.b.a.
Foamable Adhesive
high rise insulation adhesive
Royal Adhesives & Sealants,
Inc.
16.
Millennium PG-1 Low
Polyurethane two component
1.5 liters
Adco Products, Inc. d.b.a.
Viscosity Insulation
low rise insulation adhesive
Royal Adhesives & Sealants,
Adhesive
Inc.
17.
Insta Stik Quik Set
Polyurethane one component
It is supplied
The Dow Chemical Company
Insulation
moisture curing adhesive
in pressurized
cylinders with
a net weight
of 23 lbs.,
with a total
unit weight of
30 lbs.
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 6 of 42
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
18. OMG OlyBond 500 Spray polyurethane foam 10 gal. bag -in- OMG, Inc.
Adhesive insulation adhesive box set and
1.5 liters
SpotShot
cartridge
19. OMG OlyBond 500 Green Spray polyurethane foam 10 gal. bag -in- OMG, Inc.
Adhesive insulation adhesive box set and
1.5 liters
SpotShot
cartridge
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
System Number Manufacturer Application
1. Generic Gravel applied at 400 Ibs/sq., adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gaUsq.
4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
NOA No.: 17-1003.04
Expiration Date: 06/19f23
Approval Date: 04/19/18
Page 7 of 42
EVIDENCE SUBMITTED:
Test Agency/identifier
Name
Report
Date
Factory Mutual Research Corp.
FM 4470
3Y8A1.AM
03/23/96
FM 4470
OD3A3.AM
04/04/97
FM 4470
2DOAO.AM
12/23/98
FM 4470
ID7A4.AM
11/09/98
FM 4470
3039046
06/15/10
FN4 4470
3048520
09/19/13
Underwriters Laboratories, Inc.
UL 790
R11656
01/11/13
United States Testing Company
ASTM D 5147
97457-4
06/03/88
ASTM D 5147
97-457-2R
12/02/87
Momentum Technologies, Inc.
ASTM D6164
AX3108F
06/05/09
TrinitylERD
TAS 114(J)
3507.08.99-1
04118/01
TAS 114(J)
3504.06.01-1
06/05/01
TAS 114
3521.07.04
07/29/04
TAS 114
3533.01.06
01/06/06
TAS 114"
Letter
04/05/06
TAS 117 (B)
3503.10.06
10/10/06
TAS 117 (B)
06490.04.07-R1
06/27/07
TAS 117 (B)/ ASTM D 6862
C8500SC.11.07
11/30/07
TAS 114
C8370.08.08
08/19/08
FM 4470, TAS 114, FM 4470,
C8370.08.08-R1
10/05/09
TAS 114(J)
ASTM Physical Properties
C10080.09.08-R4
03/25/10
TAS 114(H), TAS 117(B), TAS
C30560.06.10
6/10/10
114(J)
FM 4470, TAS 114
C32830.07.10
7/20/10
ASTM D6164/134798
C31410.01.11-2
01/10/11
TAS 117B
C35500.02.11
02/09/11
ASTM D4601
C40050.09.12-1
09/28/12
ASTM D1876
C35460.05.11
06/16/11
ASTM D1876, TAS 114 (H),
C42110.08.12
08/13/12
TAS 117 (B)
FM 4474/TAS 114
C39670.08.12
08/20/12
ASTMD1970
C40050.09.12-2
09/28/12
ASTM D5147/D4798
C31410.10.10-R1
11/01/12
ASTM D5147/D4798
C31410.01.11-1-R1
11/01/12
ASTMD4798
C31410.01.11-2A-Rl
02/21/13
ASTM D4798
C31410.12.13
12/05/13
ASTM D6222
C40050.12.13-R1
12/31/13
TAS 117, TAS 114
C30310.12.09-R1
03/07/14
ASTM D1876, TAS 114 (H),
C45620.03.14
03/27/14
FM 4474
ASTM D 1876, TAS 114 (H),
C47320.03.14-R1
04/01/15
FM 4474
NOA No.: 17-1003.04
MLAMMAuecounrtv Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 8 of 42
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
ASTM D4601-04 (2012), Type II CTR-SC11145.09.16- 09/19/16
3A
PRI Construction Materials ASTM D6163
CTC-066-02-01
08/09/11
Technologies LLC ASTM D6222
CTC-071-02-01
08/08/11
ASTM D6222
CTC-070-02-01
08/09/11
ASTM D6164/134798
CTC-093-02-01
08/09/11
ASTMD4601
CTC-126-02-01
03/12/12
ASTM D2178
CTC-122=02-01
03/13/12
ASTM D2178
CTC-123-02-01
03/13/12
ASTMD4601
CTC-127-02-01
03/13/12
ASTM D6163
CTC-128-02-01
06/11/12
ASTM D6163
CTC-129-02-01
06/11/12
ASTM D6164
CTC-132-02-01
06/11/12
ASTM D6164
CTC-161-02-01
05/09/13
ASTM D6162
CTC-183-02-01
10/02/13
ASTM D6164
CTC-190-02-01
12/02/13
ASTMD1970
CTC-199-02-01
01/22/14
ASTM D6163
CTC 319-02-01
08/22/17
NOA No.: 17-1003.04
MAMMAD; COUNTY Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 9 of 42
APPROVED ASSEMBLIES:
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19132 " or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
woodjoists spaced maximum 24" o.c.
System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft2
ACFoam-II, Multi -Max FA-3, ENRGY 3, FlintBoard ISO, H-Shield
Minimum 1.511 thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installedas the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet,
(Optional) Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of
Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered.
Or
One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-
FR CoolStar torch adhered to base or ply sheet.
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 10 of 42
Surfacing:
(Optional)
Maximum Design
Pressure:
Any of the approved surfacing/coating options listed in Table 4.
-52.5 psf (See General Limitation #7)
NOA No.: 17-1003.04
MAMWADE COUMiY Expiration Date: WOW
Approval Date: 04/19/18
Page 11 of 42
Membrane Type:
Deck Type 1I:
Deck Description:
System Type A(2):
SBS Modified
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexi as Base
e 2 oasticPoly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Shee Glasbase
Base Sheet r Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and
approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver Insulation Fasteners Fastener
able 3 Density/ff
ACFoa_m-II ENR , ENRGY 3 25 PSI, FlintBoard ISO, H-Shield, FlintBoardu IS
'uim m•LS",,thick' N/A N/A
FescoBoard
Minimum'/4" thick N/A N/A
Structodek i h Denai Fiberboard `oati
nimrm',x"'thick N/A N/A
DensDeck, DensDeck Prime
Minimum'/" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs./sq
MUIMFMDE COUNTY
NOA No.: 17-1003.04
�Lw• • , Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 12 of 42
Ply Sheet: ie ly of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
(Optional) lintiastie Base 20 lintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet
or one or more plies of Flintglas Ply Sheet Type 1V or Flintglas Premium Ply Sheet Type VI
adhered in full mopping of approved asphalt applied within the EVT range and at a rate of
2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -
adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied.
Membrane: Qne 1 a Flintlastic GMS lintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic
FR P, Flintlastic R- o5lStar, Flintlastic Premium FR-P, Flintlastic Premium FR P
CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet
:with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bsJsq.
or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply
sheet.
Surfacing:
(Optional)
Maximum Design
Pressure:
MIAWDADECOUNTY
Any of the approved surfacing/coating options listed in Table 4.
-52.5 psf (See General Limitation #7)
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 13 of 42
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o. c.
System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and Systern,Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet; Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet, Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations
Insulation Laver Insulation Fasteners Fastener
able 3 Densi /ft2
ACFoam-H, Multi -Max FA-3, ENRGY 3, FlintBoard ISO, H-Shield
Minimum 1.5" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation 47)
Pressure:
NOA No.: 17-1003.04
MIAMMADE COUNTY Expiration Date: 06/1923
Approval Date: 04/19/18
Page 14 of 42
Membrane Type:
Deck Type 1I:
SBS Modified
Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o. c.
System Type A(4): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flin0astic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Laver
Insulation Fasteners
Table 3
ACFoam-II, ENRGY 3, ENRGY 3 25 PSI, FlintBoard ISO, H-Shield, FlintBoardH ISO
Minimum 1.5" thick N/A
Fastener
Density/ff
N/A
FescoBoard
Minimum %11 thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum %" thick N/A N/A
DensDeck, DensDeck Prime
Minimum'/4" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 15 of 42'
Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
(Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI
adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic; Ultra Glass SA self -adhered
or Flintlastic Ultra Poly SMS Base Sheet torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 C6olStar adhered to base/ply sheet with approved
mopping asphalt applied within.the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR
Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation #7)
Pressure:
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 16 of 42
Membrane Type:
Deck Type 1I:
APP Modified
Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plan attached with #8 screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System TypeB(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft=
FlintBoard ISO, ACFoam-II, H-Shield, FlintBoardn ISO
Minimum 1.5" thick 1 or 3 1:1.33
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details).
Too Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft=
FlintBoard ISO, ACFoam-II, B-Shield, FlintBoarda ISO
Minimum 1.5" thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG-
1 Low Viscosity Insulation Adhesive in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered.
Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-
FR CoolStar, torch adhered.
Surfacing: Any of the approved surfacing/coating options listed in Table 4
(Optional)
Maximum Design -67.5 psf (See General Limitation #7.)
Pressure:
NOA No.: 17-1003.04
ML4M4W, LINTY Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 17 of 42
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced" 6" o.c. at
wood joists spaced maximum W' o.c.
System Type B(2): Base layer of insulation mechanically fastened, top layer adhered with approved
adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/fti
FlintBoard ISO, ACFoam-II, H-Shield, FlintBoardn ISO
Minimum 1.5" thick 1 or 3 1A.33
Note: Base layer shall be, mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application, Standard RAS 117 for fastening
details).
Too Insulation Laver
SECUROCK Gypsum -Fiber Roof Board
Minimum 11411 thick
Insulation Fasteners Fastener
able 3 Density/fe
N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG-
1 Low Viscosity Insulation Adhesive, Insta-Stik Quik Set Insulation Adhesive, OMG OlyBond 500 or OMG
OlyBond 500 Green Adhesive in 3/4" —1" wide beads spaced 12 inch o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered.
Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered.
(Optional)
Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-
FR CoolStar, torch adhered.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -90 psf (See General Limitation #7.)
Pressure:
NOA No.:17-1003.04
MLAMMME COUNTY Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 18 of 42
Membrane Type:
Deck Type 1I:
Deck Description:
APP Modified
Wood, Insulated
15/32° or greater CDX plywood or wood plank attached with#8 screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type C(1): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Laver Insulation Fasteners
able 3
FlintBoard ISO, ACFoam-H, H-Shield, FlintBoardu ISO
Minimum 1.5" thick N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Ton Insulation Laver Insulation Fasteners
able 3
SECUROCK Gypsum -Fiber Roof Board
Minimum 1/4" thick 1 or 3
Fastener
Density/ftt
N/A
Fastener
Density/ft2
1:1.33
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet:
Ply Sheet:
(Optional)
Membrane:
Surfacing:
(Optional)
Maximum Design
Pressure:
One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered.
One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered.
One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-
FR CoolStar, torch adhered.
Any of the approved surfacing/coating options listed in Table 4.
-67.5 psf (See General Limitation #7.)
NOA No.: 17-1003.04
MIAM4DAD; COUNTY Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 19 of 42
Membrane Type: APP Modified
Deck Type 1I Wood, Insulated
Deck Description: 15/32" or greater C6X plywood or wood plank attached with #8 screws spaced 6"
o.c. at wood
joists spaced maximum'24" o.c.
System Type C(2): All layers of insulation simultaneously
attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation'I aver
Insulation: Fasteners Fastener
able 3 Density/ftx
FlintBoard.ISO, ACFoam-H, HShield,°Flintl3oat de ISO
Minimum 1.5" thick
N/A
N/A
Note: All layers shall be_simultaneously fastened; see top
layer below for fasteners and density.
Top Insulation Laver
Insulation. Fasteners
Fastener
Table 3
Deusity/ft2
FlintBoard ISO, ACFoam-H; H-Shield, FlintBoard6ISO
Minimum 1.5" thick
1 or 3
1.1.33
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and, dimensions; if larger panels are used, the number. of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One•ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered.
Ply Sheet: One or more plies of Flintlastic APP Base T or-Flintlastic STA,-torch adhered.
Membrane: One ply of Flintlastic GTA, FlintlasficGTA CoolStar, Flintlastic GTA=FR or ElintlasticGTA-
FR CoolStar, torch adhered.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75.0 psf (See General Limitation #7.)
Pressure:
NOA No.i 17-1003.04
MLAMMADEGOUNTII. Expiration Date' 06/19/23,
Approval Date: .04/19/18:,
Page 20. of 42 .
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank mails spaced 6" ox at
wood joists spaced maximum 24" o.c.
System Type E(I): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather /'Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base. Sheet
mechanically attached as detailed below.
Fastening: Fastened with SimplexMAXX Cap fasteners spaced '9",o.c. in,the2" side lap and 12" o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap,
Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-
P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved
mopping asphalt applied within. the',EVT range and at a rate of 20-40 Ibs/sq. or one ply of
Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied.
Surfacing: Any of the approved surfacing/coafmg options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #9)
Pressure:
NOA No.: 17-1003.04
MIAMFDADECOUNTr Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 21 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non -insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6" o.c.
at wood joists spaced maximum o.c.
System.Type E(2): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below.
Fastening: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap,
Flintlastic FR P, Flintlastic FR P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-
P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of
Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation 49)
Pressure:
MIAMFDADE COUN7Y
NOA No.: 17-1003:04
. • • • � � Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 22 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet:
One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening:
Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in;the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet:
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional)
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar
torch adhered to basdply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page'23 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(4): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic
Ultra Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Mintlastic FR Cap 30 CoolStar adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR
Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 24 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8d ring shank nails spaced 6" o.c.
at wood joists spaced 24" o.c.
System Type E(5): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as
described below.
Fastening: Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four,
equally spaced staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-401bsJsq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
MIAM4DADE COUNTY NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 25 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non-hisulated
Deck Description: 1 9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c. at
wood joists spaced maximum 24" o. c
System Type E(6): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar
torch adhered to base/ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation #7)
Pressure:
MiAMMADE COUNTY NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 26 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 1 9/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 4" o.c, at
wood joists spaced maximum 24" o. c
System Type E(7): Base sheet mechanically fastened.
All General and System Limitations apply
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with I 1 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic
Ultra Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR
Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf. (See General Limitation #7)
Pressure:
MIAMFOADE COUNTY NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 27 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or -greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced at maximum 24" o.c.
System Type E(8): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet orFlintlastic Ultra Poly SMS Base
Sheet, mechanically attached asdescribed below.
Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8" o.c, at the 3" lap
and 8" o.c. in three, equally spaced center rows.
Ply Sheet:
One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered.
Membrane:
One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar,
Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet
with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.
or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing:
Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -60 psf (See General Limitation #7.)
Pressure:
MIAMMADE COUNTY NOA No.:17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18'
Page 28 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(9): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more layers of Glasliase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SM&Base
Sheet, mechanically attached as•described below.
Fastening: Anchor sheet shall be fastened with FBC RYHZ nails and tin caps spaced 8" o.c. at the 3" lap
and 8" o.c. in three, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR
torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(optional)
Maximum -Design -60 psf (See General Limitation #7.)
Pressure:
MUUIFnADE COUNTY
NOA No.: 17-1003.04
. • • . , , Expiration Date: 06/19/23
Approval Date: 04119/18'
Page 29'of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6"o.c. at
wood joists spaced maximum 24" o.c.
System Type E(10): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid.
(Optional)
Base Sheet: One or more layers of Glasbase-Base Sheet, Yosemite Venting Base Sheet Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastiq Poly SMS Base Sheet of Flintlastic Ultra Poly SMS Base ,
Sheet, mechanically attached asdescribed below.
Fastening: OMG #12 Standard Roofgrip fasteners with OMG 3" Galvanized Steel Plates or AccuTrac
Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or Flintfast #12
fasteners with Flintfast 3" plates spaced 7" o.c. at the 4" wide laps and 7" o.c. in two, equally
spaced staggered center rows.
Ply Sheet: One ply of Flintlastic Ultra Glass SA, selfadhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet
with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.
or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -67.5 psf. (See General Limitation 47)
Pressure:
MIAMFDADE COUNTY NOA No.: 17-1003.04
� , • .. , , Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 30 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 11/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c.' at wood
joists spaced maximum 24" o.c.
System Type E(11): Base'sheet mechanically fastened
All General and, SystemLimitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Fli_mlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All-Weather/Empire Base Sheet, mechanically attached as described Below.
Fastening: Anchor sheet shall be fastened with HVM nails and tin caps spaced 6" o.c. at the 3" lap and 6
o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic
FR-P,.Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P
CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered
to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20
to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T. CoolStar torch adhered to
ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf (See General Limitation #7.)
Pressure:
MIAM4nADECOUNTY
NOA No.: 17-1003.04
• • • � � .Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 31 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(12): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One of more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All Weather/Empire Base Sheet, mechanically attached as described below.
Fastening: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 3
o.c. is four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR
torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -82.5 psf (See General Limitation #7.)
Pressure:
MIAMFDADE COUNTY
NOA No.: 17-1003.04
, • • • � � Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 32 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/3z' or greater CDX plywood or wood plank attached with#10 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(13): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet:
One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and
6" o.c. in two evenly divided, staggered rows in the center of the sheet.
Membrane:
One ply of Flintlastic FR Cap 36, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap,
Flintlastic FR-P, FlintlasticFR:P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P
CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of
Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied.
Surfacing:
Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design
-90 psf. (See General Limitation#9)
Pressure:
NOA No.: 17-1003.04
nwnFoanecourrry Expiration Date: 06/19/23
Approval Date: 04/19/18'
Page33 of 42
£3
Membrane Type: APP Modified,
Deck Type 1: Wood, Non -Insulated =_
Deck Description: is/az" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6 o coat
wood joists spaced r`
J P maximum 24" o.c.
System Type E(14): Base sheet mechanically fastened. 4
1
,,-
All General and System Limitations apply.
sx
a: _s
Base Sheet:
One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap
fasteners
spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in
the cent"'
of the sheet.
Membrane:
One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic
GTA F
CoolStar, torch -applied
as
Surfacing:
Any of the approved surfacing/coating options listed in Table 4.
(Optional)
94
Maximum Design
-90 psf. (See General Limitation #4)
}
Pressure:
xu
=v55
LPr
APPROVED
NOA No.:
Expiration Dad
Approval Dad
Page 34 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(15): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheetmechanically attached as
described -below.
Fastening: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal 'Plates; ' OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, F1intFast #12 or F1intFast # 14 fasteners with
F1intFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in three, equally spaced
staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq. or
one or more plies of Flintlastic Base 20 T or Flindastic Ultra Poly SMS Base Sheet, torch
applied.
Membrane: One ply of Flintlastic G.MS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR.
P,, Flintlastic FR P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Opti(nal)
Maximum Design -97.5 psf. (See General Limitation #7)
Pressure:
MU1MFnADE COUNOA No.: 17-1603.04
N7'r
... , , Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 35 of 42
Membrane Type: SBS Modified
Deck Type 1I: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(16): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and
6" o.c. in three evenly divined, staggered rows in the center of the sheet.
Ply Sheet: None
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap,
Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P
CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, adhered to base sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of
Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf. (See General Limitation #9)
Pressure:
MIAMFnf1DE COUNTY
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 36 of 42
Membrane Type:
APP Modified
Deck Type 1I:
Wood, Non -Insulated
Deck Description:
15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4"o.c. at
wood joists spaced maximum 24" o.c.
System Type E(17):
Base sheet mechanically fastened.
All General and System Limitations apply.
Base Skeet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners
spaced 6" o.c. in the 2" side lap and'6" o.c. in three evenly divided, staggered rows in the center
of the sheet.
Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR
CoolStar, torch -applied
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf. (See General Limitation 49)
Pressure:
NOA No.: 17-1003.04
MIAM4DADE COUNTY Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 37 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: "/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(18): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening: Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round
Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation
Plates or FlintFast #12 Fasteners with F1imFast 3" Insulation Plates spaced 7" o.c. at the 4" lap
and 7 o.c. in three, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR P CoolStar,
Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet
with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.
or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105.0 psf (See General Limitation #7.)
Pressure:
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 38 of 42
Membrane Type: SBS Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 19132" or greater plywood or wood plank attached with 48 wood screws spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(19): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One ply of Glasbase Base Sheet, loose laid
(Optional)
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet, mechanically attached as described below.
Fastening: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and
4" o.c. in four, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet
with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.
or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf (See General Limitation #7.)
Pressure:
ML4MFOADE COUNTY
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 39 of 42
Membrane Type: APP Modified
Deck Type 1: Wood, Non -Insulated
Deck Description: 11/32" or greater plywood or wood plank attached with #8 wood screws spaced 6" o.c. at
wood joists spaced maximum 24" o.c.
System Type E(20): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet: One ply of Glasbase Base Sheet, loose laid
(Optional)
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase
Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly
SMS Base Sheet, mechanically attached as described below.
Fastening: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3"
lap and 4" o.c. in four, equally spaced center rows
Ply Sheet: One ply of Black Diamond Base Sheet, self -adhered.
Membrane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Ftintiastic GTA-FR CoolStar or
Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -105 psf (See General Limitation P.)
Pressure:
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18
Page 40 of 42
Membrane Type: SBS Modified
Deck Type 1I: Wood, Non -Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4" o.c. at
wood joists spaced maximum 24" o.c.
System Type. E(21): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as
described below.
Fastening: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, FlintFast # 12 or F1imFast # 14 fasteners with
FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced
staggered center rows.
Ply Sheet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
(Optional) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane:
One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic FR Dual Cap, Ftintlastic FR-
P, Flintlastic FR-P CoolStar, Flintlastic Premium FR P, Flintlastic Premium FR-P CoolStar,
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet.
Surfacing:
Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design
-127.5 psf. (See General Limitation #7)
Pressure:
MWMFnADEt.OUNTY
NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: o4/19/18
Page 41 of 42
WOOD DECK SYSTEM LIMITATIONS:
I. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 2040 lbs./sq, or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MUIM4MDE COUNTY NOA No.: 17-1003.04
Expiration Date: 06/19/23
Approval Date: 04/19/18