iAPPENDIx'1:ATrAQJMENT{REQUIREMENTS FOR WIND UPLIFT RESISTANCES;.',!"-''"'
`",i .,
:'''. ,, ;" ' }`.v"r. 1 - 'r"' '�
... "
_ -
Table
Deck
Application
Type
Description
Page
SA
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New or Reroof(Tear-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
6
IE
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
7
1F
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
8
1G
Wood
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
9
11-1
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
9
2A
Steel or Concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
10-14
2B
Steel or Concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
15-18
2C
Steel or Concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
19-21 -
3A
Structural concrete
New or Reroof(Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
22-26
3B
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Temporary Roof, Bonded Insulation, Banded Roof Cover
27
3C
Structural concrete
New or Reroof (Tear -Off)
F
Norrinsuiated, Bonded Roof Cover
28
3D
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover, Paver System Overburden
28 -
4A
LWIC
New or Reroof (Tear -Off)
A-1
LWC to Deck, Bonded Insulation, Bonded Roof Cover
29-32
4B
LWIC
New or Reroof (Tear -Off)
A-2
LWC to Deck, Mach. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
33
4C
LWIC
New, Reroof (Tear -Off) or Recover
C
LWC to Deck, Mech. Attached Insulation, Bonded Roof Cover
33
4D
LWIC
New or Reroof (Tear -Off)
E
LWC to Deck, Mach. Attached Base Sheet, Bonded Roof Cover
34-38
4E
LWIC
New, Reroof (Tear -Off) or Recover
E
LWC to Deck, Mech. Attached Base Sheet, Bonded Roof Cover
39
4F
LWIC
New or Reroof (Tear -OR)
F
LWC to Deck Bonded Roof Cover
39
4G
LWIC
New or Reroof (Tear -Off)
F
LWC to Deck Bonded Roof Cover, Paver System Overburden
39
SA
CWF
New or Reroof (rear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
40
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
41
5B
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
41
5C
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
42
SO
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
42
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
43
6B
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
44-45
6C
Gypsum
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
45
6D
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. AttachedInsulation, Bonded Roof Cover
46 /
6E
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
46
7
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
47 49
8
Various
Summary of FBC 423.25A.1 EHPA Systems per SSTD 12-99
50
Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report J8230.03.08-R11 for FL2948-1112
CertljJcote ofAuthorize Non 49503 6reEDITION (2017)FBC NON-HVHZ EVALUATION - Revision 11: 10/14/2017
Prepared by: Robert Nieminen, PE-59166 Johns Manville SBS Modified Bitumen Roof Systems; (303) 9784879 Appendix 1, Page 1 of 50
�I I KINIiY ERD
I
The following notes apply to the systems outlined herein:
1. The evaluation herein pertains to above -deck roof components. Roof decks and structural members shall. be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load
resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Ultral'ast Fasteners or All Purpose Fasteners with UltraFast Metal Plates. Minimum 0.75-Inch plywood penetration or minimum 1-Inch wood plank embedment.
➢ Steel. Deck: UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates. Minimum 0.75-Inch steel penetration and engage the top flute of the steel deck.
D Structural concrete: All Purpose Fasteners with UltraFast Metal Plates or Structural Concrete Fasteners with UltraFast Metal Plates (flat bottom only). Minimum 1-Inch embedment. Fasteners Installed
with a pilot hole in accordance with the fastener manufacturer's published Installation Instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurete, polystyrene, wood fiberboard, pedite, gypsum -based roof board, that meets the CIA requirements of F.A.C. Rule -3 and is
documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for, or Installed below the rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover),
whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structuraldeck shall be of equal or greater configuration to the steel and concrete deck listings.
Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified
and/or FBC Approval documentation.
S. Preliminary Insulation attachment for System Type D:Refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, Insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published instructions.
➢ Not asphalt (HA): Full coverage at 25-30lbs/square
➢ JM MBR Bonding Adhesive (MBR-BA): Continuous 0.75-Inch wide ribbons,12-Inch o.c. or full coverage at 2.0 gal/square
D 1M Two -Part Urethane Insulation Adhesive (UTA-2): Continuous 0.75-Inch wide ribbons,12-Inch o.c. Note: JM Green rwo-Port Urethane Insulation Adhesive may be used where UTA-2 Is referenced.
➢ JM Roofing System Urethane Adhesive (RSUA): Continuous 0.5 to0.75-Inch wide ribbons, 12-Inch o.c.
➢ JM One -Step Foamable Adhesive (OSFA): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
➢ ICP Adhesives CR-20: Continuous 2.5 to 3.5-Inch ribbons, 12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the speck led ribbons spacing
7. Unless otherwise noted, all Insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to'Increase' the MOP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system In the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ 1M Two -Part Urethane Insulation Adhesive(UTA-2): MDP -325.0 psf (Min. 0.5-inch thick)
➢ JM Roofing System Urethane Adhesive(RSUA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ JM One -Step Foamable Adhesive (OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ ICP Adhesives CR-20: MOP -117.5 psf (Min. 1.04nch thick)
8. Bonded polyisocyanurete insulation boards shall be maximum 4x 4 ft.
1
9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WD3, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressurefor the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis Is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5105.
Exterior Research and Design, U.C. d/b/a Trinityl ERD Evaluation Report 18230.03.08-R31 for FI2948-R12
Certificate of Authorization #9503 r EDITION (2017) FBC NON-HVHZ EVALUATION Revision 11: 10/14/2017
Prepared by: Robert Nieminen, PE-59166 Johns Manville SBS Modified Bitumen Roof Systems; (303) 978.4879 Appendix 1, Page 2 of 50
�1 I RINITY ERD
12. For existing substrates In a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation Is optional. Alternatively, an FBC Approved coverboard may be used as a separator board, preliminarily attached prior to roof cover Installation. The
existing roof system shall be suitable for a recover application.
14. Lightweight Insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-
coat thickness is 2-Inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
15. Unless otherwise noted, refer to the following references for bonded base, ply orcap sheet applications.
;, _.-' .�' .;.-.>-. ...,.: "y�`--'r '•.. 'JOHNSMANVILLEROOFCOVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
GlasBase Plus, PermaPly 28
(Base and Ply sheets,
Ply
GlasPly IV, GlasPly Premier, GlasBase Plus, PermaPly 28
Hot asphalt at 20-40 lbs/square
Asphalt -Applied)
BP -CAI
(Base and Ply sheets, Cold-
Base Ply or Ply
GlasBase Plus, PermaPly 28
1M MBR Cold Application Adhesive
Applied, 1-part)
at 1.5 to 2.0 gal/square
BP-CA2
(Base and Ply sheets, Cold-
Base Ply or Ply
GlasBase Plus, PermaPly 28
MBR Bonding Adhesive at l.5 to
Applied, 2-part)
.
2.0 gat/square
2
BP-Cf3
(Base and Ply sheets, Cold-
Base Ply or Ply
- GlasBase Plus, PermaPly 28, GlasPly IV, GlasPly Premier
rm
JM Premium Cold App at 1.5 to 2.0
gal/square
Applied, I- art)
Base Ply or Ply
DynaPly TI, Dynallase, DynaBaseXr, DynaBase PR, Dynalastic 180 S, Dynalastic 250 S, DynaLastic 250 FRS
585-AA
DynaPly TI, DynaKap TI, DynaKap FR T3, DynaKap FR TS CR, DynaKap FR T3 CR G, DynaGlas, DynaGlas FR, DynaGlas FR Xr, DynaGlas FR
(SBS, Asphalt -Applied)
Cap Ply
XT CR, DynaGlas FR XT CR G, DynaGlas FR CIL DynaGlas FR CR G, DynaGlas 30 FR, DynaGlas 30 FR CR, DynaGlas 30 FR, DynaGlas 30 FR CR
Hot asphalt at 20-40lbs/square
XT, DynaLastic 180 S, Dynalastic 250 S, DynaLastic 250 FR S, DynaLastic 180, DynaLastic 180 FR, Dynalastic 180 FR CIL Dynalastic 180 FR
CR G, Dynalastic 250, DynaLastic 250 FR, DynaLastic 250 FR CIL D nalastic 250 FR CR G, DynaMax FR, DynaMax FR CR, DynaMax FR CR G
Base Ply or Ply
DynaPly TI, DynaBase, DynaBase XT, DynaBase PR, DynaLastic 1805, DynaLastic 2505, DynaLastic 250 FRS
SBS-CAS
DynaPly T1, DynaKap TI, DynaKap FR TI, DynaKap FR TI CIL DynaKap FR TI CR G, DynaGlas, DynaGlas Fit, DynaGlas FR XT, DynaGlas FR
JM MBR Cold Application Adhesive
(SOS, Cold -Applied, 1-part)
Cap Ply
XT CR, DynaGlas FR XT CR G, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas 30 FR, DynaGlas 30 FR CR, DynaGlas 30 FR, DynaGlas 30 FR CR
at 1.5 to 2.0 gal square
XT, DynaLastic 180 5, DynaLastic 250 S, Dynalastic 250 FR 5, DynaLastic 180, Dynalastic 180 FR, DynaLastic 180 FR CR, Dynalastic 180 FR
CR G, Dynalastic 250, Dynalastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G, DynaMax FR, DynaMax FR CR, DynaMax FR CR G
Base Ply or Ply
DynaPly TI, DynaBase, DynaBase XT, DynaBase PR, DynaLastic 180 S, Dynalastic 250 S, Dynalastic 250 FRS
DynaPly Ti, DynaKap 71, DynaKap FR 71, DynaKap FR TS CIL DynaKap FR TS CR G, DynaGlas, DynaGlas Fit, DynaGlas FR XT, DynaGlas FR
SBS-CA2
Cap Ply
XT CR, DynaGlas FR XT OR G, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas 30 FR, DynaGlas 30 FR CR, DynaGlas 30 FR, DynaGlas 30 FR CR
JM MBR Bonding Adhesive at 1.5 to
(SB5, Cold -Applied, 2-part)
XT, DynaLastic 190 5, DynaLastic 2505, DynaLastic 250 FR S, Dynalastic 180, Dynalastic 180 FR, DynaLastic 180 FR CR, Dynalastic 180 FR
2.0 gal/square
CR G, DynaLastic 250, DynaLastic 250 FR, Dynalastic 250 FR CR, DynaLastic Z50 FR CR G, DynaMax FR, DynaMax FR CR, DynaMax FR CR G
Note:
SBS-CA2 applications shall not be'mixed'wlth SBS-AA applications
Exterior Research and Design, LLC. d/b/a TrinItyI ERD Evaluation Report J8230.03.08-1131 for FL2948-R12
CerN/Jcate of Authorization g9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 11: 10/14/2017
Prepared by: Robert Nleminen, PE-59166 Johns Manville SOS Modified Bitumen Roof Systems; (303) 9784879 Appendix 1, Page 3 of 50
111� NTINITYIERD
'JOHNS MANVILLE Roof COVERS(C'O'NTINUED)";
Reference
Layer
Material
Application
Base Ply or Ply
DynaPly T1, Dynallase, DynaBase XT, DynaBase PR, Dynalastic 180 S, DynaLastic 250 S, Dynalastic RO FRS
SBS-CA3
DynaPly T1, DynaKap T1, DynaKap FR T1, DynaKap FR TI CR, DynaKap FR T1 CR G, DynaGlas, DynaGlas FR, DynaGlas FR XT, DynaGlas FR
JM Premium Cold Apo at 1.5 to 2.0
(SBS, Cold -Applied, 1-part)
Cap Ply
)(T CR, DynaGlas FR XT CR G, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas 30 FR, DynaGlas 30 FR CR, DynaGlas 30 FR, DynaGlas 30 FR CR
gal/square
XT, Dynalastic 180 S, DynaLastic 250 S, Dynalastic 250 FR S, DynaLastic 280, DynaLastic 180 FR, DynaLastic 180 FR CR, DynaLastic 180 FR
CR G, DynalastIc 250, Dynalastic 250 Fit, DynaLastic 250 FR CR, Dynalastic 250 FR CR G, DynaMax FIR, aMax FIR CR, aMax FR CR G
Base Ply or Ply
DynaBase HW, DynaWeld Base, DynaWeld 180 S
SBS-TA
DynaWeld Cap FR, DynaWeld Cap FR CR, DynaWeld Cap FR CR G. DynaWeld Cap 180, DynaWeld Cap 180 CR, DynaWeld Cap 180 FR,
Torch -Applied
(SBS,Torch-Applied)
Cap Ply
DynaWeld Cap 180 FR CR, DynaWeld Cap 180 FR CR 6, DynaWeld Cap 250, DynaWeld Cap 250 CR, DynaWeld Cap 250 FR, DynaWeld Cap
250 FR CR, DynaWeld Cap 250 FR CR G, DynaClad, DynaClad Copper
SBISI�A
Base P or P
2,2 Gdp Base SD/SA, DynaGrip Base SA/SA, JMCIeanBond SBS Base Sheet
(SBS,a
SBIf-adhering)
p ZY
1 DY,!Ejp Cap, JMClean3ond SBS Cap Sheet
Self -Adhering
16. Modified bitumen vapor barrier options for use over structural concrete deck followed by adhered Insulation applied as follows carry the following Maximum Design Pressure (MDP) limitations. The lesser of the
MDP listings below vs. those in Table 3A applies:
,VAPbRBARR]iROPTIONs,'SiRO&V"LCbNCiEt,b
PC , K111OU640 BWA&dim fgiaATIok P'ERTAq , I; 3A:,
Option N
Primer
Vapor Barter
Insulation Adhesive
MDP (Pso
VB-1.
ASTM D41
Two plies GlasPly IV, GlasPly Premier In hot asphalt
JM Roofing System Urethane Adhesive
-180.0
(RSUA), 12-Inch o.c.
VB-2.
ASTM D41
Two plies GlasPly IV, GlasPly Premier In hot asphalt
JM One -Step Foamable Adhesive (OSFA),
-180.0
12-inch O.C.
DynaPly T1, Dyna8me, DynaBase XT, DynaBase PR, Dynalastic 180 S, Dynalastic 2SO S, Dynalastic 250 FR S In hot asphalt
JM One -Step Foamable Adhesive (CSFA),
VB-3.
ASTM D41
or DynaBase HW, DynaWeld Base, DynaWeld 1805 torch -applied
12-Inch o.c.
-180.0
VB-4.
JIvI SA Primer Low
JM Vapor Baffler SA, self -adhered
JM Two -Part Urethane Insulation
-277.5
VOC
Adhesive (UIA-2), 12-inch o.c.
VB-S.
JM SA Primer Low
JM Vapor Barrier SA, self -adhered
JM Roofing System Urethane Adhesive
-277.5
VOC
(RSUA), 12-Inch o.c.
DynaPly T1, DynaBase, DynaBase Xr, DynaBase PR, Dynalastic 180 S, DynaLastic 2505, Dynalastic Z50 FR S In hot asphalt
JM Two -Part Urethane Insulation
VB-6.
ASTM D41
or DynaBase KW, DynaWeld Base, DynaWeld 180 S torch -applied
Adhesive (UIA-2),12-inch o.c.
-277.5
VB-7.
ASTM D41
DynaPly T1, DynaBase, DynaBase XT, DynaBase PR, DynaLastic 180 S, Dynalastic 250 S, Dynalastic 250 FR 5 In hot asphalt
JM Roofing System Urethane Adhesive
-277.5
(RSUA), 12-Inch o.c.
VB-8.
ASTM D41
DynaBase HW, DynaWeld Base, DynaWeld 180 S torch -applied
JM Roofing System Urethane Adhesive
- 292.5
I
I
(RSUA), 12-Inch o.c.
17. "MDP' = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a Trinity] ERD Evaluation Report J8230.03.OB-R11 for FL294&R72
certiflcate of Authorization 49503 Gt" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 11: 10/14/2017
Prepared by: Robert Nlemlnen, PE-59166 Johns Manville SBS Modified Bitumen Roof Systems; (303) 9784879 Appendix 1, Page 4 of 50
�i TRJNITYERD
-
W CONSTRUCTION Da REROOF
,..
SYSTEM,d1fPEE'IMECHANICA�LL9 ATiACHEDBA5E5FIEETi B0NOEDR0OFC0VER,.:,;
,TAB
..
System
Deck
LWC
Base Sheet
Roof Cover (Note 15)
MDP
Type
Fasteners
Attach
Base Ply
Cap Ply
No.
(Note 3)
(Note 14)
(Psf)
Min. 22 ga, type B,
DynaBase, GlasPly
1M LWC OR Base
7-Inch o.c. at the 4-Inch lap and
BP -AA, BP-CA2
SBS-AA, SBS-
LWC-73
Grades steel or
Min. 300 psi, minimum 2-inch [hick CelcoreLWIC
Premier,lation ly 28
7-inch,staIn equally
SBS-AA,
-75.0
structural concrete
arVentsulation
Sheet Fastener
gtwo,
spaced, staggered center rows
CA2 dr SBSTA
CA2 or SBS-TA
Trufast Twin Loc
Min. 22 ga, type B,
Min. 498 psi, minimum 2-Inch thick Celcore MF
Tubes or 1M Ultrelok
6-Inch o.c within the min.4-
LWC-72
Grade 33 steel or
Cellular Concrete with Celcore HS Rheology
DynaFast 180 HW or
Tube (1.8-Inch)
inch wide, heat -welded side laps
(Optional) SBS
SBS-TA
-75.0
structural concrete
Modifying Admixture
DynaFast 250 HW
through Trufast
and 6-inch o.c. In one center
TA
Batten Bar or JM
row
Metal Batten TL
Min. 22 ga, type B,
Min. 430 psi, minimum 2-Inch thick Elasthell LWIC
PermaPly 28, GlasBase
JM LWC CR Base
7-Inch o.c. at the 4-Inch lap and
SBS-AA, 5B5-
LWC-73
Grade 33 steel or
with Zell -Crete Fibers
Plus, DynaBase or
Sheet Fastener, min.
7-inch o.c. In two, equally
SBS-AA, SBS-TA
TA
-75.0
structural concrete
Ventsulation
1.7-Inch
spaced, staggered center rows
Min. 22 ga, type B,
Min. 430 psi, minimum 2-Inch thick Elastizell LWIC
JM LWC CR Base
7-inch o.c. at the 4-Inch lap and
SBSCAI, SBS-
505-CA-1, SBS-
Gradesteel
with Zell -Crete Fibers
DynaBase
Sheet Fastener, min.
7-Incho.c.intwo, equally
CA2
CA2
-75.0
structural
structuras l concrere te
1.7-Inch
spaced, staggered center rows
Min. 22 gad type B,
Grade 33
Min. 300 psi, minimum 2.25-inch thick Concrecel
GIasP Premier,
PermaPly2&
JM LWC CR Base
7-Inch oats of the4-inrh lap and
]-inch in
BP -AA, BP-CA2
SBS-AA SBS-
LWC-
steel or
LWIC I
r
Sheet Fastener
o.c. two, equally
SBS-AA SBS-
CA20 58ST
_ SZS
structural concrete
entsulatio
spaced, staggered center rows
CA2 or5BSTA
.
Min. 22 ga, type B,
Min. 300 psi, minimum 2.25-inch thick Concrecel
1M LWC OR Base
7-inch o.c at the 4-Inch lap and
LWC-76
Grade 33 steel or
LWIC. Note: To qualify the LWC; thefostenersholl
PermaPly 28
Sheet Fastener
7-inch o.c in two, equally
SBS-CA3
SBSCA3
-90.0
structural concrete
document min. J031bfper Note 11.
(Note 11)
spaced, staggered center row
Trufast Twin Loc
Min. 498 psi, minimum 2-Inch thick Celcore MF
Tubes orJM UltraLok
6-Inch o.c. within the min. 4-
LWC-77
Structural concrete
Cellular Concrete Celcore HS Rheology
DynaFast 180 HW or
Tube (1.8-Inch)
inch wide, heat -welded side laps
(Optional) SBS-
SBS-TA
-90.0
Modifying Admixture
re
DynaFast 250 HW
through Trufast
and 6-Inch o.c. in one center
TA
Batten Bar or lM
row
Metal Batten TL
Min. 300 psi, minimum 2-inch thick Concrxel LWIC.
PermaPly 28,
1M LWC CR Base
6-Inch oats at the4-Inch lap and
LWC-78
Structural concrete
Note. To qualify the LWC, thefastenershall
Ventsulation,
Sheet Fastener
6-Inch o.c at three, equally
BP -AA or SBS
SBS-AA
-120.0 I'
document min. 981b per
fP Note 11.
DynaBase or GlasPly
(Note 11)
spaced, staggered center rows
AA
Premier
Min. 22 ga, type B.
Trufast FM•290
7-Inch o.c. at the 4-Inch lap and
BP -AA, BP-CA2
SBS-AA, SBS-
LWC-79
Grade 33 steel or
Min. 300 psi, minimum 2-Inch thick Meadcrete
GlasPly Premier
7-inch oats in two, equally
SBS-AA, SBS
-127.5
structural concrete
Fasteners
spaced, staggered center rows
CA2 or SBS-TA
CA2 or SBS-TA
Min. 22 ga. type ed
50%strip mop plus: Fasteners 4-
BP -AA, BP-CA2
LWC-BD
Grades steelre
Min. 300 psi, minimum 2.25-Inch thick Concrecel
GlasPly Premier
JM LWC OR Base
Inch o.c. at the 4-Inch lap and 4-
SBSAA,SBS
SBS-AA, SBS-
-146.0
structural concrete
LWIC
Sheet Fastener
Inch o.c. In four equally spaced;
CA2 or SBSTA
CA2 or SBS-TA
staggered center rows
Exterior Research and Design, U.C. d/b/a Trinity(ERD Evaluation Report 18230.03.08-11I1 for FL2948-R32
Certificate of Authorization 49503 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 11: 10/14/2017
Prepared by: Robert Nieminen, PE-59166 Johns Manville SBS Modified Bitumen Roof Systems, (303) 978-4879 Appendix 1, Page 38 of 50