Loading...
HomeMy WebLinkAboutBUILDING SCHEMATIC191 DM'a ffAK ROOF hWJGNT n DESIGN WIND_ PASS M FOR COMPONENTS A a AFPM (M F,) FOR ASCE_7-110 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET �r BASIC WIND SPEED = 170 mph RISK CATEGORY /1 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I- LESS THAN 7'-9' I- GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3' I' GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGANVE POSITIVE ' NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. UL77MATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15, 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 1077 64.6 773 46.4 974 58.4 > 30'-40' 90.7 54.4 127.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-s0' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 872 52.3 709.9 65.9 BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I- LESS THAN 12-3' 1- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE - NEGATIVE POSH/VE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTMATE A.S.D. > 60' - 70' 97.5 54.9 167.7 100.6 84.3 50.6 748.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 j FQ;d" o;A 95.6 aL7 Aay a 175.2 aTD5. 88.0 52.8 155.0 93.0 > 90' - 100' 97.3 - .4 178.4 107.4 1 89.7 53.8 1579 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57.1 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - Lao' 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 55.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 30o' - 350, 121.0 72.6 221.9 133.1 1 111.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.'9 120.5 > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 77.3 236.1 141.7 118.6 71.2 208.9 125.3 N 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A B451C WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & DIPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORM477ON FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER /F USED TO OBTAIN A ONE 77ME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART WIND PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC). INDICATED DESIGN WMD PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. L-= STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. it PRODUCTS WHICH BEM A MAMI-DARE COUNTY OR A STATE OF FLORIDA APPROVAL ,ZOOif 101 Go FILE COPY N. No. g4167 L AP 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER