g "Ei 'Product Approval
+t USER: Pubk User
S`q h..yi-
PmdudAnorovalMenu>PmtludorAvorratbneearch>Aooira[ionLat>Appliimtionlietail SCANNED
FL # FL1850-Ril BY
Application Type Revision St. Lucie County
Code Version 2017
Application Status Approve0
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
lrodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method - Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
n Evaluation Report - Hardmpy Received
Florida Engineer or Architect Name who developed the Walter A. Tillit, Jr., P.E.
Evaluation Report
Florida License
PE-44167
Quality Assurance Entity
National Accreditation and Management Institute
Quality Assurance Contract Expiration Date
12/31/2018
Validated By
John Henry Kampmann Jr.
P Validation Checklist - Hardcopy Received
Certificate of Independence FLI850 RI1 COI AMERICAN SHUTTER SYSTEMS INC DRAWING
17-102 CERTIFICATE OF IND P NDEN E PDF
Referenced Standard and Year (of Standard) Standard Year
ASTM E1886 2005
ASTM E1996 2005
ASTM E330 2002
TAS 201, 202, 203 - 1994
Equivalence of Product Standards
Certified By
1 of 3 12/15/2017, 3:18 PM
Florida Building Cdde Online
https://www.floriaar)uilding.oi&r: pr_app_dtl.aspx?param=7JGEVXQw...
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/03/2017
10/13/2017
10/17/2017
12/12/2017
FL # ( Model, Number or Name Description
1850.1 ( Bertha HV Accordion -Blade 3 (HVHZ) i; Extruded aluminum blades folded together thru knuckles and
Drawing# 17-103 (retained by tracks to provide hurricane protection.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D". Max span is 12'-7" for 35 psf
positive ASD load and 13'-0" for 35 psf negative ASD load for
one specific condition shown in span tables. See additional
loads and spans on engineered drawings.
1850.2 Bertha HV Accordion Shutter
(Combo) - HVHZ - Drawing#17-102
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D". Max. span is 13'-2" for 30 psf
positive ASD load w/o window blade, 16'-0" for 30 psf negative
ASD load for HV1 blade w/o window blade for conditions
indicated on schedule #1, sheet 12. And 12'-3" for 30 psf
positive ASD load w/o window blade and 15'-5 for 30 psf
negative ASD load for HV2 blade w/o window blade. See sheets
number 12, 25, 28 and 28A of installation drawings for other
spans and pressures.
Installation Instructions
FLIB50 RII II AMERICAN SHUTTER SYSTEMS ASSOC INC
DRAWING 17-103 BERTHA HV ACCORDION SHUTTER
SYST..PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL1850 R11 AE AMERICAN SHUTTER SYSTEMS ASSOC
INC DRAWING 17-103 PRODUCT EVALUATION REPORT PDF
Created by Independent Third Party: Yes
Extruded aluminum interlocking blades retained by tracks (top
and bottom) for storm protection
Installation Instructions
FLIB50 1111 II AMERICAN SHUTTER SYSTEMS INC
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
Created by independent Third Party: Yes
1850.3 Bertha HV Accordion Shutter- Blade '.. Extruded aluminum interlocking blades retained by tracks (top
1 Only (HVHZ) - Drwg# 17-122, and bottom) for storm protection
Limits of Use �^
Approved for use in HVHZ/
Approved for usee HVHZ: Yes
Impact Resistan Yes
Design Pressure:
Other: Large missile level "D". Max, span is 16'-0" and 14'-9"
for 30 psf ASD negative load depending on centermates and
locking rod configuration forthe HVS blade, B'-0" for +64, -72
psf load for HV blade for Keystone mountings 7'-0" for +75, -75
psf for metals stud mountings and W-0" for 110 psf. for HVI
and HVSA working in unison. See sheets 7, 11, 20 and 19
respectively of installation drawings for other spans and
pressures.
Installation Instructions
FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC INC
DRAWING 17-122 BERTHA HV ACCORDION SYST PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
Created by Independent Third Party: Yes
oatl Hart
fyL iict U :: 1601 ar qmm Rand. Tataha«ce FL 32199 Phone' 850-487-1824
The State of Florida is an weeOempbyen C,avright -7013 state of Flag :: Privacy Statement::Arn«PoS�F•at�,_e_ent:: Refund Statement
Under Fonda law, email addresses are pubic records. ryou do not want your e-maladdress released in response to a pubic -records request, do not send electronic mall
0 this catty. Instead, contact the office by phone or by traditional man. If you have any quWtons, phase contact 850.487.1395.-Pumuent to Section 455A75(1), Florida
statutes, effective October 1, 2012, kemem Ocorved under Chapter 455, F.S. most pmvtle the Department wth an email address lithe, have one. The emalls pmvlied
may be used for official communication with the licensee. However email addresses are public record. V you do pot woub to supply a personal address, please provide the
Departmentwith an amid address which can be made avalable to the polik. To determine t you are a kamee under Chapter 455, FS., please tick he, .
product Approval Accepts:
2 of 3 12/15/2017, 3:18 PM
Florida Bdilding Cbde Online • https://www.floridabuilding.org/p r/pr_app_dtl.aspx?param=wGEVXQw...
securitvntsriiocs'
3 of 3 12/15/2017, 3:18 PM