Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online https://www.floridabuilding.o_,- _'pr_app_dtl.aspx?paramwGEVXQw... mv aCZ Home Ing in I User Registration I Hof Topics Submt Surcharge Stats & Fads Publbatbrt ( Fec st ff I K S Ste Map I Unks j Seamh dba r g "Ei 'Product Approval +t USER: Pubk User S`q h..yi- PmdudAnorovalMenu>PmtludorAvorratbneearch>Aooira[ionLat>Appliimtionlietail SCANNED FL # FL1850-Ril BY Application Type Revision St. Lucie County Code Version 2017 Application Status Approve0 Comments Archived Product Manufacturer American Shutter Systems Association, Inc. Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 (561) 209-8263 bfeeley@easternmetal.com Authorized Signature Bill Feeley lrodriguez@easternmetal.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Shutters Subcategory Accordion Compliance Method - Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer n Evaluation Report - Hardmpy Received Florida Engineer or Architect Name who developed the Walter A. Tillit, Jr., P.E. Evaluation Report Florida License PE-44167 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By John Henry Kampmann Jr. P Validation Checklist - Hardcopy Received Certificate of Independence FLI850 RI1 COI AMERICAN SHUTTER SYSTEMS INC DRAWING 17-102 CERTIFICATE OF IND P NDEN E PDF Referenced Standard and Year (of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2005 ASTM E330 2002 TAS 201, 202, 203 - 1994 Equivalence of Product Standards Certified By 1 of 3 12/15/2017, 3:18 PM Florida Building Cdde Online https://www.floriaar)uilding.oi&r: pr_app_dtl.aspx?param=7JGEVXQw... Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 10/03/2017 10/13/2017 10/17/2017 12/12/2017 FL # ( Model, Number or Name Description 1850.1 ( Bertha HV Accordion -Blade 3 (HVHZ) i; Extruded aluminum blades folded together thru knuckles and Drawing# 17-103 (retained by tracks to provide hurricane protection. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Level "D". Max span is 12'-7" for 35 psf positive ASD load and 13'-0" for 35 psf negative ASD load for one specific condition shown in span tables. See additional loads and spans on engineered drawings. 1850.2 Bertha HV Accordion Shutter (Combo) - HVHZ - Drawing#17-102 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Level "D". Max. span is 13'-2" for 30 psf positive ASD load w/o window blade, 16'-0" for 30 psf negative ASD load for HV1 blade w/o window blade for conditions indicated on schedule #1, sheet 12. And 12'-3" for 30 psf positive ASD load w/o window blade and 15'-5 for 30 psf negative ASD load for HV2 blade w/o window blade. See sheets number 12, 25, 28 and 28A of installation drawings for other spans and pressures. Installation Instructions FLIB50 RII II AMERICAN SHUTTER SYSTEMS ASSOC INC DRAWING 17-103 BERTHA HV ACCORDION SHUTTER SYST..PDF Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports FL1850 R11 AE AMERICAN SHUTTER SYSTEMS ASSOC INC DRAWING 17-103 PRODUCT EVALUATION REPORT PDF Created by Independent Third Party: Yes Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection Installation Instructions FLIB50 1111 II AMERICAN SHUTTER SYSTEMS INC Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports Created by independent Third Party: Yes 1850.3 Bertha HV Accordion Shutter- Blade '.. Extruded aluminum interlocking blades retained by tracks (top 1 Only (HVHZ) - Drwg# 17-122, and bottom) for storm protection Limits of Use �^ Approved for use in HVHZ/ Approved for usee HVHZ: Yes Impact Resistan Yes Design Pressure: Other: Large missile level "D". Max, span is 16'-0" and 14'-9" for 30 psf ASD negative load depending on centermates and locking rod configuration forthe HVS blade, B'-0" for +64, -72 psf load for HV blade for Keystone mountings 7'-0" for +75, -75 psf for metals stud mountings and W-0" for 110 psf. for HVI and HVSA working in unison. See sheets 7, 11, 20 and 19 respectively of installation drawings for other spans and pressures. Installation Instructions FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC INC DRAWING 17-122 BERTHA HV ACCORDION SYST PDF Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes oatl Hart fyL iict U :: 1601 ar qmm Rand. Tataha«ce FL 32199 Phone' 850-487-1824 The State of Florida is an weeOempbyen C,avright -7013 state of Flag :: Privacy Statement::Arn«PoS�F•at�,_e_ent:: Refund Statement Under Fonda law, email addresses are pubic records. ryou do not want your e-maladdress released in response to a pubic -records request, do not send electronic mall 0 this catty. Instead, contact the office by phone or by traditional man. If you have any quWtons, phase contact 850.487.1395.-Pumuent to Section 455A75(1), Florida statutes, effective October 1, 2012, kemem Ocorved under Chapter 455, F.S. most pmvtle the Department wth an email address lithe, have one. The emalls pmvlied may be used for official communication with the licensee. However email addresses are public record. V you do pot woub to supply a personal address, please provide the Departmentwith an amid address which can be made avalable to the polik. To determine t you are a kamee under Chapter 455, FS., please tick he, . product Approval Accepts: 2 of 3 12/15/2017, 3:18 PM Florida Bdilding Cbde Online • https://www.floridabuilding.org/p r/pr_app_dtl.aspx?param=wGEVXQw... securitvntsriiocs' 3 of 3 12/15/2017, 3:18 PM