HomeMy WebLinkAboutBUILDING SCHEMATIC% z.'NPy CG rUK LV "FUPoGNI.S d ULAMUTTV(s (f J I / PUN Aal& i�TV BASIC WIND SPEED = 170 mph RISK CATEGORY lI BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) I PEAK ROOF L'• LESS THAN 7'-9" L- GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" L" GREATER OR EQUAL THAN 12'-J" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25-30' 1 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4 97,4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 872 52.3 109.9 65.9 SCANNED BY St. Lucie County * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. 7k L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. ** PRODUCTS WHICH BEAR A MIAMI-DADS COUNTY OR A STATE OF FLORIDA APPROVAL 6Ul XM'S PEAK ROOF HEIGHT vs DESIGN W/ND PRESSURE FOR COMPONENTS A CLADDING (& IF.) F.) FOR AS•E 7 10 PEAK ROOF HEIGHT GREATER THAN 60 F£Fr ak BASIC WIND SPEED = 170 mph RISK CATEGORY N BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) FILE Cu"' PY PEAK ROOF L•• LESS THAN 12-3" L- GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 7 ' - 93.6 171.E 03!O 86.2 51.7 151.9 91. 1 > 80' - 90' 95.6 574 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - Too' 1 97.3 58.4 178.4 107.4 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57. 1 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - 180' 107.8 64.7 1976 1 1 & 6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350'1 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 > 350' - 400'1 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450'1 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 5OO'l 128.8 1 77.3 1 236.1 1 141.7 1 118.E 1 71.2 1 208.9 1 125.3 N07E5: 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10. FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) COWMC70R OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WINO PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE UL77M47E AND ASO. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED IWAUD IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS MAID LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/)AKE OFF SHEET, ETC). 77, pia 11'�: ••••VC 4L. No•44167 ?s"' (O i 0Go 41 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDL4N RIVER IL ECO 7mc. ASC£ 7-10 / WIND PRESSURE CHART STORM PANELS. ACCORDION & BAHAMA SHUTTERS RISK CAT. II BUTS WIND PRESSURE CHART BASIC WIND SPEED = 170 mph EXPOSURE D, Kd = 0.85 LC. +rr DRAWN BY 0B/09/17 DATE 17-194 wa DRAWING No SHEET i OF 1