To Whom It May Concern:
Our office has calculated the required design pressures in accordance with ASCE 7-10
for a replacement of the windows at the above referenced address.
Wind speed: V lt: 165 mph, V.d: 128 mph
Exposure: D
Enclosure Type: Enclosed
Window Size: Per Attached Sketch (Same Size as Windows Removed).
Location: Zone 5 Worst Case (4'h Floor)
Required Design Pressure Worst Case (Zone 5): +51.3 / -68.7 PSF
Windows to be installed shall be equal to, or exceed the required design pressures as
listed above. All window and buck installations shall be in accordance with FBC 2017
and manufacturer's installation instructions.
Proposed Window: PGT Industries Inc. SH-700 NOA#17-0630.08
(+80/ -80 PSF).
Proposed Mullions: PGT Industries Inc. 1X2.75X.375 NOA#17-0630.01
(+76.2/ -76.2 PSF).
Thank you for your attention to this matter.