Loading...
HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com July 11, 2018 Re: Window Replacement SCANNED 10200 S. Ocean Dr. Suite 410 BY Jensen Beach, FL 34957 St. LUCIE County To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 for a replacement of the windows at the above referenced address. Wind speed: V lt: 165 mph, V.d: 128 mph Exposure: D Enclosure Type: Enclosed Window Size: Per Attached Sketch (Same Size as Windows Removed). Location: Zone 5 Worst Case (4'h Floor) Required Design Pressure Worst Case (Zone 5): +51.3 / -68.7 PSF Windows to be installed shall be equal to, or exceed the required design pressures as listed above. All window and buck installations shall be in accordance with FBC 2017 and manufacturer's installation instructions. Proposed Window: PGT Industries Inc. SH-700 NOA#17-0630.08 (+80/ -80 PSF). Proposed Mullions: PGT Industries Inc. 1X2.75X.375 NOA#17-0630.01 (+76.2/ -76.2 PSF). Thank you for your attention to this matter. Submitted by: PAU LCH INC. ST. LUCIE CpUNTy Paul ch, P.E. REVIEWED FOR Ep REVIE Reg. No 29945 DATE W7 7 SITE OR NO FILE COPS' WILL BE MADE