Loading...
HomeMy WebLinkAboutDESIGN CALCULATIONSE as peals t ' easyseals.com DESIGN CALCULATIONS FOR BURGER KING #576 MONUMENTSIGN 6598 US Hwy i — Port St Lucie SCANNED BY St. Lucie County GENERAL NOTES: 1. Design is in accordance with the Florida Building Code 6th Edition (2017) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein, exceptwhere noted. otherwise.. 3. These engineering calculations pertain only to the structural integrity of Index: those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The Pg 1 Cover existing host structure (if any) is assumed to be in good condition, Pg 2 wind Loads capable of supporting the loaded system, subject to building department Pg 3 Footing Design approval. No warranty, either expressed or implied, is contained herein. Pg4 Primarysupport(s) 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. S. Where site conditions deviate from those noted herein, revisions may be Y required or a separate site -specific engineering evaluation performed. ``41r1uur..*4,s Eng;�e � t�ial valid ,� ��. •� Q` 1�,g 6. Aluminum components in contact with steel or embedded in concrete••tn� shall be protected as prescribed in the 2015 Aluminum Design Manual, No. 67 8 Part 1-A. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. -'� ;• 7. Engineer seal affixed hereto validates structural design as shown only. TA •�� '�%�Ot•: Jun ..S9,'4. . Use of this specification by contractor, et. AI, indemnifies and saves .".. Cti fi # 67382 harmless this engineer for all costs & damages including legal fees & ,q@ apellate fees resulting from deviation from this design. EOSy:Se�19nnn( �Auth # 31124 Federal Hwy, nzoo Easy Seals .com Page 1 BocaRaton, ton, FL 33432 EasySeals mm CALCULATIOI FOR FREESTANDING SIGNS ASCE 7-10 Design Wind Loads FREESTANDING SOLID SIGNS AND WALLS (AT GRADE) Building Specs V = j' ik mph i Basic wind speed Risk Category 1 Structure Exposure - C ASD Load Combo Coeff- �0.6 Calculations a=9.5 3-sec gust speed power law exponent Zg = 900' Nominal ht. of atmos. boundary layer G = 0.85 150 mph - Exp "C" Monuments at grade W/Ht Ratios 0.5 DESIGN SIGN WIND HEIGHT PRESSURES 15 ft ± 32.9psf 18 ft ± 34.1 psf 20 ft ± 34.9 psf 30 ft ± 38.0 psf 35 ft ± 39.3 psf 40 ft ± _40.4 psf 45 ft ± 41.4 psf Soft . ± 42.3 psf 55 ft ± 43.2 psf 60 ft ± 44.0 psf 70 ft ± 45.4 psf 80 ft , ± 46.7 psf 90 It ± 47.9 psf 100 ft ± 49.0 psf 110 It . ± 50.0 psf 120 ft ± 50.9 psf 130 ft ± 51.8 psf 140 It ± 52.6 psf 150 ft ± 53.3 psf 175 ft ± 55.1 psf 200 It ± 56.7 psf 250 ft ± 59.4 psf Kd = 0.85 Directionality factor KA = 1.0_ =-Top�rophiefaaror_ _ _ E~-- - Cf = 1.55 Force Coefficient ..Width/Height ratio >_0.5 YQ: - --- -- -- - --- 0.85 24.9 0.88 25.9 0.90 26.5 0.98 28.9 1.01 29.8 1.04 30.7 1.07 31.4 - - - -- - - 1.09 32.1 1.12 32.8 1.14 33.4 1.17 34.5 1.21 35.5 - -------- 1.24 36.4 - - - - -- - _-- - --- --- - -- - ------ _ 1.27 37.2 -- 1.29 37.9 - - - 1.32 38.6 1.34 39.3 1.36 39.9 1.38 40.5 -- - - 1.42 41.8 1.46 43.0 1.53 45.1 Page 2 ',OEasySeals CALCULATION: 'FOR FREESTANDING SIGNS ,`M Footing Design For Freestanding Signs and Flagpoles Structure Dimensions & Loading Design wind pressure: P = j 32.9 j psf Overturning Safety Factor: Q _i 1.5 i ... FBC 1807.2.3 Sign area 1: Al= 49.5 - isq ft ... tributary area 1 for each footer (e.g. sign) Height of applied force above grade: h1= 4.0 ift ... height of area 1 centroid Sign area2: A2=; 0.0 isgft ... tributary area 2 for each footer (e.g. post) Height of applied force above grade: h2 = i 0.0 � ft ... height of area 2 centroid Overturning Moment: Mn = P*(Al*hl+A2*h2) Mn = 6.5 kip-ft LSq / Rect! Footing dimensions: Footing depth: Superstructure weight: Soil cover weight: Footing weight: Total weight: 13=3� 3.75 Ift Dr=4 --1 200__Ib Ds= 0 lb Df= 5273 lb D = 5473 lb Soil Strength ...FBc rubles 1806.2,1819.6 Soil class: r 4.'Sand, silty sand, silty gravel ' Lateral bearing strength: Plat = 150 psf/ft Vertical bearing strength: Pbrg = 2000 psf Check Vertical Soil Bearing Pressures e = - 1.19 ft ...=(P)*(Al*hl+A2*h2) / D qtoe = 2*D/[3*L*(B/2-e)) qtoe = 1418 psf Resisting moment due to Dead Load: My = D*13/2 My = 10.3 p__._ —.T L=L_3'.75�-eft _ Soil cover: ds =s _ TO �;ft ... = 100pcf*B*L*ds ... = 150pcf*B*L*d ...=Dr+Ds+of ...reaction below footer at toe kip-ft Total Resisting Moment: Mtot = My / 0 Mtot= 6.8 kip-ft ... > B/6 qtoe < Pbrg OK Mtot > Mn OK Page 3 . ) EasySeaLs CALCULATIOI, FOR FREESTANDING SIGNS Hollow Structural Pipe in Bending Allowable Stress Design per 2010 AISC Spec for Structural Steel Buildings Material Properties Yield Stress, A53 Grd B Steel: Fy =1 '35 rv.'r ksi Safety Factor =!_ -,1.69 Per section 133.4 Modulus of Elasticity: E = . 29000 ksi End Supports: I Cantilever Member Properties ANSI 5" Schedule 40 steel pipe Nominal size: _Vidiam - (Sch 40 Outside Diameter _ d =( 5.563 'in Moment of Inertia: Ix = 15.2 in' Wall Thickness t=1J0.258 Iin Section Modulus: S= _SAS in' �V Deflection Limit: Defl Design wind pressure: P = 32.9 j psf Sign area: Al = 49.5 j sq ft ... tributary area for each post (e.g. sign+post) Eccentricity of applied force: e1= t _4`0 . ft ... distance to area centroid (weighted avg hl,h2) (1): Yielding Limit State Mn = Fy*S Allowable Moment: Mallow = Mn / 1.67 Mn = 190.8 kip -in Mallow = 114.2 kip -in Check Member Bending Moment in member: Mmax = P*Al*el Mmax = 78.1 kip -in Check Member Deflection: Allowable-beflection: Aaiiuw = 0.60 in Deflection in member: Amax= P*(A*eA3) / (3*E*1) Amax= 0.14 in L/80 Mmax < Mallow... OK Amax < Aallow ... OK Page 4