Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE4 1=• -' J i� Planning & Development Services Department RECEIVED • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462- 553 JUL 2 5 2018 Certification for Design Load Compliance ST. Lucie County, permitting Project Name: BURGER KING #575 kiCU #2 Project Address: U.S. Hwy 1 & S.E. Leninard Road Port St. Lucie, FL 34952 Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed _Open 3. Risk Category: X I X 11 _III _ IV Exposure Category: _B X C _D ' 4. Design Wind Velocity mph X ASD _LRFD End Zone Width: N/A` ft 5. Mean Roof Height 30 ft Roof Pitch: N/A :12 Parapet: 30 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +36.1 Zone 5: +46.0 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: SIGNAGE ONLY 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,stortblerlag Hof my knowledge and belief, the attached plans & specifications have been designed to compil 4bjtK n..1i?a,b fructural portions of the building codes currently adopted and enforced by St. Lucie Cou 7atsyaE`SCruttural elements depicted on these plans provide adequate resistance to the design foe' ec'fed: o. 67382 CHRISTIAN LANGLEY PE 67382 / CA 31142 =. a , *Digitally sigfe&by Print Name Cert # & Co. Cert Auth. Christian Langley am Na,ATarEE%Fe:208 ya9 EASY SEALS ENGINEERING, LLC (dba EASY SEALS) 0. Signat 1200 N FEDERAL HWY, #200 - BOCA RATON, FL 33432 I,,,II110gooCompany Name &Address Revised 07/2S/2014 HLE "NOPY