HomeMy WebLinkAboutMISC LETTER1 M.A. CORSON & ASSOCIATES. Inc. ARCHITECTURE x STRUCTURAL DESIGN 1121 S.E. Ocean Blvd., Stuart, Fl. 34996 (772) 223-8227 * Lie. #AR91665 Date: September 13, 2018 St SCgy/V' To: St. Lucie County - Building & Code Regulation Division �UCie Cobn$' Re: Mark Riley 9900 S. Ocean Drive Unit 606 Jensen Beach, Fl. , 34957 It is acceptable to replace existing sliding glass door openings for the address listed above with a new non -impact sliding glass door made by PGT Window Systems. There are existing approved hurricane shutters to cover the openings. The "5470 " vinyl sliding glass door has a Florida number NOA-#17-0420.07. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +60 / -60 design pressure. The actual building design pressures of address listed above in Zone 4 is +51.4 / -56.3. The building has a type II classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated. Thank you for your time and consideration. If you have any questions please call. Respectfully, trk. Corson -A.I.A., NCARB President CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD ST. LUCIE COUNTYZL BUILDING DIVISI REVIEWE FOR COMP ANCF MUST BE KEPT ON 40B OR NO INSPECTION WILL/SE MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS ti REQUIRED BY FIEU IMPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICAM CODES. /., eAj jqow- RECEIVED WINDOWS & DOORS September 12, 2018 St. Lucie County Building Department 2300 Virginia Ave Fort Pierce, Fl. 39482 772-462-1553 REVISION - PERMIT # 1807-0851 Please review the following corrections. SEP 13,2018 Permitting Department St. Lucie County 1. Replace engineering to reflect non -impact product approval 2. Copy of building permit for new shutters installed 3. NOA originally submitted will now concur with engineering report r Sincerely J et Milici Natural Flow 391 NE Baker Rd. • Stuart, FL 34994 (772) 334-1011 • FAX (772) 334-1078 • www.naturalflow.net m WINDOWS & DOOR; September 18, 2018 St. Lucie County Building De 2300 Virginia Ave. Fort Pierce, Fl. 34982 772-462-2172 Andrew: Attached please find revisioi 1. Architects signed lett 2. Copy of NOA Thank you, 0'anet',liciFlow 391 NE Baker Rd. • Stuart, FL 34994 (772) 334-1011 • FAX (772) 334-1078 • www.naturalflow.net rd— PAUL WELCH LNC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pcvelchinc@aol.com SCANNED June 20, 2018 —r- r:;, BY Ude County Re: Riley Shutter Installation 9900 S. Ocean Dr. (#606) Jensen Beach, FL 34957 " To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. Wind speed: V i,: 165 mph, V, d: 128 mph Exposure: D Enclosure Type: Enclosed CONTRACTOR Shutter Size: 96" Maximum Height 1 09 Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2017. - Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. Submitted by: PAUL WELCH INC. Pau Welch, P.E. Reg. No 29945