HomeMy WebLinkAboutCALCULATIONSForensic tngineering Consult 'ants, Inc. METAL PANEL ATTACHMENT CALCULATIONS Project Name Gazebos Report No.: SRI-MP-18.001 Project Address 10410 South Ocean Boulevard Jensen Beach, FL Deck Substrate Wood Insulated Mean Roof Height 15.0 Feet Configuration Steep Slope Roof Area (Approx.) Sq.Ft. Category II Roof Width 40.0 Feet Exposure Condition D Perimeter Width 4.0 Feet Building Type Not Enclosed Parapet Height 0.0 Feet Base Wind Speed 170 mph Sloped Roof Type Slope V 6.0 Slope H 12.0 Slope Angle° 26.57 Slope V 6.0 Slope H 12.0 Slope Angle° 26.57 Uplift Pressures q� = 0.00256 K� Ka Kd V2 P = q� (GCP - GCP;) qZ Kz Ke Kd V GCP GCP1 65.097 1.030 1,005 0.85 170 -0.90 0.55 Field -1.70 0.55 Perimeter -2.60 0.55 Comer Field P1 UK. -94.39 psf P1 asd -56.63 psf SCANNED Perimeter P2A -145.47 psf P2asd -87.88 psf BY Corner P3an. -205.06 psf P3asd-123.03 psf St. Lucie County Proposed System Englert Series 2000 0.032" Aluminum Snap -Lock Roof Panel System Product Approval No. FL11751.2-R6 Panel Width 18 inches (Per NOA) 18 inches (Actual) System Design Pressure -82.5 psf (Field)-123.75 psf (Perimeter/Corner) Fasteners Approved Clips with 2 corrosion resistant #10 Pancake Head Screws per clip, that are long enough to penetrate through decking a minimum of 3/16" Max. Clip Spacing per NOA 18 inch (Field) 12 inches (Perimeter) # Rows 1 Fastener Withdrawal Resistance-185.63 Ibf (Field)-185.63 Ibf (Perimeter/Comer) Min. Characteristic Resistance Force-185.63 Ibf (Field)-185.63 Ibf (Perimeter/Comer) Fastener Spacing ((MCRF/Pi) x 144)/(Panel Width/No. of Rows of Fasteners) Field Clip Spacing 26.22 inches Perimeter Clip Spacing 16.90 inches Corner Clip Spacing 12.07 inches RECOMMENDED FASTENER SPACING Field Clips installed at 18" o.c. Perimeter Clips installed at 12" o.c. Comer Clips installed at 12" o.c. ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIAIJ/F REVIEWED BY. MUST BE KEPT ON JOb OR NO INSPECTION WILL Eq= MAE These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Ensure that roof system meets all life and fire safety requirements of the Florida Building Code, before installation. Sincerely Fo an Engineering Consultants, Inc. N R. N. Sailappan, P.E.. ZAU�11191111.8 Principal Engineer Florida Registration No. 46696 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY COFIRECTIONS REQUIRED BY FILD INSPECTORS THAT WY UE NECE^SUff IN ORDER TO COMPLY WITH ALL APPLICADILE CODES. : ONCWB FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD Forensic Engineering Consultants, Inc. (CA #8265), P.O. Box 970034, Boca Raton, FL - 33497 Ph