HomeMy WebLinkAboutENGINEERINGy
Architectonic Inc
St. Lucie County
Planning & Development Services
Building and Code Regulation Division
August 14, 2018
RE: 2995 S. 251h Street
To Whom It May Concern:
a -C;13»
ST. LUCIE COUNTY
BUILDING DIVISIOWA
REVIEWED
FOR COMP
REVIEW
DATE
LAN, 3 AND P RMIT
MUST BE KEPT N JOB OR
NO INSPECTION ILL BE MADE
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Store Front is in compliance with the 2017 Florida Building Code, 160 mph wind zone,
Exposure "B", Risk Category H.
From Table 1609.3.1: v,,,= 160mph
Va:d= 124mph
From Table 1609.6.2 Zone 5 enclosed 1.34
Required Design Pressures: 23.Sx 1.34 = 31.49
-28 x 1.34 = -37.52
THESE PLANS AND ALL PROgOSEO VWX
ARE SUBJECT TO ANY CA"RECTICNS
REQUIRED BY FIELD INSKOTORS MIAT
"VOE NECES•SARy IN ORDER TO
CONPI.YWITNALLAPPLICAUE CODES,
Product: Coral FL500 Dry Glaze and FL500 Framing System, FL# 10467-R5 and FL# 15793-R3
Product Pressures: + 1/45 and +70/-80
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CON&CTOR OF RECORD
'SCANNED
St. Lucie County
i
d 4 %:a _r�•� � I
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of.1