Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 Certification for Design Load Compliance Project Name: Roof Project Address: 900 Rock Rd. Fort Pierce, FL Permit #: Occupancy Type: R Construction Type: V • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed —Partially Enclosed Open 3. Risk Category: _ 1 II X III IV Exposure Category: _ B X CD 4. Design Wind Velocity 170 mph 132 ASD N/A LRFD End Zone Width_ 5 ft 5. Mean Roof Height: 12.3 ft Roof Pitch: o.s :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.0 16.0 16.0 Zone 1: 37.3 Zone 2: -58 8 Zone 3: -83.9 Zone 4: N/A Zone 5: N/A Garage: 7. Design Loads: Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:_ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? —&--Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? —X_Yes_Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: _Jy(A__PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT, I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certjfy that structural elements depicted on these plans provide adequate resistance to the design forces specified: I Signature, Date, adq Seal SLCCDV Form # 020-12 Revised 3/15/12 (1S) Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address