HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553
Certification for Design Load Compliance
Project Name: Roof
Project Address: 900 Rock Rd. Fort Pierce, FL
Permit #:
Occupancy Type: R Construction Type: V
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
1. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed —Partially Enclosed Open
3. Risk Category: _ 1 II X III IV Exposure Category: _ B X CD
4. Design Wind Velocity 170 mph 132 ASD N/A LRFD End Zone Width_ 5 ft
5. Mean Roof Height: 12.3 ft Roof Pitch: o.s :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
16.0 16.0 16.0
Zone 1: 37.3 Zone 2: -58 8 Zone 3: -83.9 Zone 4: N/A Zone 5: N/A Garage:
7. Design Loads: Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:_ N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
8. Were Shear Walls Considered For Structure? —&--Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? —X_Yes_Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: _Jy(A__PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT,
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certjfy that structural elements depicted on these plans provide adequate resistance to the design
forces specified: I
Signature, Date, adq Seal
SLCCDV Form # 020-12 Revised 3/15/12 (1S)
Paul Welch P.E. 29945 / 5115
Print Name Cert # & Co. Cert Auth.
Paul Welch Inc.
1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
Company Name & Address