Loading...
HomeMy WebLinkAboutMANUALGRATE Alva) F Model Nun VGB WARNING Read and keep 2008 A owner'smanua injuryand/or do IMPORTANT SAFETY INSTR WARNING -SUCTION ENTRAPI Suction in suction outlets and/or su covers which are damaged, broken, �. missing, or unsecured can cause see or death due to the following entral Hair Entrapment: Hair can become entangled in OWNER'S MANUAL 640-477XV 18"x18"Grate&Frame !se instructions for future reference. Follow all instructions in this id on the equipment. Failure to follow instructions can cause severe h. TIONS r HAZARD Body Suction Entrapment: A negative pressure applied to a large outlet portion of the body or limbs can result in an entrapment uryand/ hazards: cover. Limb Entrapment: A limb inserted into an opening of `suction outlet sump or suction outlet coverthat is damaged, broken, crAed, missing, or not securely attached can result in a mechanical bind orswelling of the limb. j Evisceration / Disembowelment Entrapment: A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration / disembowelment entrapment. Mechanical Entrapment: There is potential forjewelryeswimsuit, ..... -- hair decorations, finger, toe, or knuckle to —be Caught -in' —an opening of a suction outlet cover resulting in mechanical entrapment. TO REDUCE THE RISK OF ENTRAPMENT HAZARDS: r7 • Use two or more suction fit019 on each any listed (per ASME A112.19.8-2007) suction outlet cover installed. IUpc'I pump suction line. The suction r�fittings In the event of one suction outlet being completely blocked, the shall be separated by a in nimrI of ft. remaining suction outlets serving the system shall have a flow rating (91.44cm),orifanyarelocatedcloserthey capable of the full flow of thepump(s). shall be located on two differe t planes Never use a pool or spa if any suction outlet component is damaged, (i.e., one on the bottom and one on the vertical wall, or he each on broken, cracked, missing, or not securely attached. two separate vertical wall). Replace damaged, broken, cracked, missing, or not securely attached • In the event of one suction outlet being completely blocked, the suction outlet components immediately. remaining suction outlets serving that system shall have a flow • Two or more suction outlets per pump should be installed in rating capable of the full flow of the pump(s)for the spelificsuction accordance with latest APSPStandards and CPSCguidelines, and system. follow all National, State, and Local codes applicable. • Dual suction fittings shall not be located on seating area :or on the • Replace the suction within 7 years from the installation date. backrest for such seating areas. • Installation of a vacuum release system, which relieves entrapping • The maximum system flow rate shall not exceed the flov 'rating of suction, is recommended. USE ONLY GENUINE WATERWAY REPLACEMENT PARTS. , SCANNED tt,, ICS'BY Designed. Si. Lucie COUiTtj'};;yyM Engineered & Manufactured - in the USA. 2200 East Sturgis Road, Wald CA 93030 • Phone 805.981.0262 • Fax 805.981.9403 02015 waterway Plastics www.waterwayplistics.com • waterway@waterwayplasties.com 810-4n0.091e WARNING Failure to remove pressure test plugs outlets can result in an increased pot Failure to keep suction outlet comp can result in an increased potential r plugs used in winterization of the pool/spa from the suction for suction entrapment as described on the previous page. clear of debris, such as leaves, dirt, hair, paper and other material, tion entrapment as described on the previous page. A Suction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at least every seven years, or if found to be damaged, broken, cracked, missing, or not securely attached. The 18"x 18"/ 640-477XV fitting broken, replace with a fitting of entrapment of the body which a Do not use or operate pool, spa, or instructions. The suction fitting is missing, broken or improperly sea at 788 GPM for floor and 517 GPM for wall. If the fitting is missing or ent rating or higher. Use of a lower rated suction fitting could result in ult in serious injury including drowning. if this suction fitting is missing, broken or not secured per d to prevent entrapment of the body. Use of the spa hot tub with a tion grate may result in serious personal injury including drowning. When the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must 1 be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or hot tub blocks this fitting with his/her body, serious personal injury or drowning may -occur. In order to remove the suction cover (for service or winterization), using a Phillips head screw driver remove C ` the screws. Inspect both the suction cover and suction fitting for any cracks or damages. It is imperative to securely attach th suction cover to the wall fittings (use only the original supplied screws r� or obtain original replacements). Do rot over tighten the screws. Inspection of fasteners and observation for damaged/tampered with suction fittings is required. I be replaced prior to starting spa or pool pump. Never operate spa or Any and all broken or missing parts pool without drain cover in place andproperly affixed, death or serious injury can result. [' Do not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower. Do not allow children to sit, play or interact with main drains or suction outlet. u 1i 6 1 M J A t � J4 . 610-4770.0916 ®2016 Waterv+ay Plastics 6 Head Loss Cume-18"08" 5- 4 II a = 3 o o so 1W ,So IN no 50o ISO 160 i_ FI"waau l6Ptl) 02016 Watemay Plastics 810-4770.0916 A C INSTRUCTIONS IN 1.5 A min. A min. 1.5 A min. Amin. GENERAL NOTES: (a) D= inside diameter of pipe. (b) All dimensions shown are minimums. (c) A broken line (_ _ -j indicates suggested sump configuration. The design of field fabricated sumps shall b the considerations of cover/grate loadings, particular to the site. THE USE OF FIELD BUILT SUMPS FIELD BUILT SUMP F11 Amin. 15 Amin. 7,71 nM :7� specified by a Registered Design Professional so as to fully address 1, hair, finger, and limb entrapment issues, as well as features waRRar�r For product registration v(sit: wwTw waterwayplastics.com. For Warranty questions or claims please contact point of purchase. @2016 Waterway Plastics 1 810-4770.0916