HomeMy WebLinkAboutTECHNICAL DATA0
O
J
Pool, Spa & Fountain Finishes
DIAMOND BRITE
Exposed Aggregate Pool Finish
TECHNICAL DATA � � 0 CP
APPLICABLE STANDARDS
ASTM International (ASTM) ANSI American National Standard Institute (ANSI)
ASTM D 4086, ASTM E1477, ASTM E 1347
tj Many building departments and health departments require commercial swimming
pool and spa finish coatings shall be comprised of a non -pigmented white
cementitious binder and shall have a dry Lightness level (CIE L value) of 80.0 or
-` - - - greater and a wet Luminous Reflectance Value (CIE Y value) of 50.0 or greater. The
Reflectance Value wet test shows the reflective value of a finish with "0" being the least relective and "100" being the
most reflective. Please see the recorded test values in the table below.'
"Pool finish, including bottom and sides, shall be of white or light colored material determined visually to contrast
least with a value of gray whiter than 50 percent black on an artist's gray scale, or shown by reflectance testing to
reflect more than 50 percent of visible light." Please see the recorded test values in the table." Please consult your
state's compliance requirements for commercial pool and spa finishes.
r)
c
W
c
0
ty
U
41
E
E
E
U
1L
0
01
Diamond Brite Color
CIE L Value
DRY
CIE Y Value
WET
Reflectance Value
WET 0 -100
PREMIUM WHITE
88.28
65.67
81
SUPER BLUE
81.09
52.3
73
BLUE
82.65
53.79
74
COOL BLUE
84.43
54.33
76
BLUE -QUARTZ
84.00
54.1
67
095A86.03
58.49
78
OYSTER QUARTZ
82.22
57.55
77
AQUA QUARTZ
84.08
54
66
PEARL
85.34
56.25
68
MARLIN BLUE
81.89
52.98
72
AQUA BLUE-
.83.83
54.06
75
CLASSIC
82.19
53.33
74
ONYX
44.54
7.71
39
FRENCH GRAY
64.2
21.5
48
TAHOE BLUE
65.13
25.07
49
MIDNIGHT BLUE
56.04
16.89
41
MOJAVE BEIGE
72.76
28.37
48
VERDE
65.28
26.27
44
'Wighlighted finishes comply with Florida Building Code 454.1.2.4 for commercial use.
"Refers to Florida building and health requirements "North Carolina rules governing public swimming pools 15A NCAC 18A.2514
requirements.
fn
Our material is tested and certified by independent laboratories. All data is given in good faith, however, we reserve the right to change
products and specifications without notice. SGM advises interested parties to satisfy themselves as to the accuracy of any data and seek
cerfification If appropriate.