Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FLOOR PLAN
SITE SPECIFiLk; FLOOR PLAN: SCALE: N.T.S. N 155' MIN. BUILDING DIM. BUILDING FOOTPRINT PLAN VIEW UNIT NEXT 6CANNED BY ' ude County WALKWAY DESIGN NOTES: FLORIDA BUILDING CODE SIXTH EDITION (2017) ASCE 7-10 Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED STRU�G9'U1.2©N N RISK CATEGORY=II, Kd=0.65, Kzt=1.0, Kz=TABLE 30.3-1, GCpi=+/-0.18 �� V _ �Q ,'' UC P = qh ((GCp)-(GCpi)) Kd*V*V MRH=200', ZONE(S) AS NOTED, ROOF TYPE'MONOSLOPE', ROOF SLOPE 0.00 No PE PRESSURES: NOTED BELOW - INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS GENERAL NOTES: ,')p'', I T STATE 1. THIS ENGINEERED PLAN IS INTENDED TO PROVIDE SITE -SPECIFIC DESIGN PRESSURES FOR THE R6FEt(dEDE( O RI STRUCTURE FOR THE PURPOSE OF THE INSTALLATION OF GLAZED/NON-GLAZED PRODUCTS AS PROPO,SCsID'Q1NU -, PROVIDED BY OTHERS. NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IS OFFERED AS TO THE dpLlDtPriA OR APPLICABILITY OF ANY PROPOSED SYSTEM OR COMPONENT USED ALONG WITH THESE PRESSURES UNIl§�Y/ VA PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN. / / / 1 I I 2. NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS REQUIREMENTS. ALL EGRESS ISSUES ARE TO BE ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL. 3. THIS CERTIFICATION APPLIES TO THE STRUCTURAL PERFORMANCE OF THE SYSTEM ONLY DOES NOT INCLUDE THE CERTIFICATION OF WATER INFILTRATION OF FIRE SAFETY. 4. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS WORK REPLACES THE EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISTING HOST STRUCTURE, THIS ENGINEER SHALL BE NOTIFIED BEFORE CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO RE -INSPECT AND RE-EVALUATE DESIGN, NO WARRANTY, EITHER EXPRESSED OR IMPLIED, IS CONTAINED HEREIN. SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL VERIFY DURING CONSTRUCTION THAT THE SUBSTRATE IS OF THE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE WITH THE INTENT OF THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS. 5. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN. 6. ANY JUNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS OUTSIDE THE SCOPE OF THIS CERTIFICATION. 7. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 8. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND SHALL BE MINIMUM S.SX THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR — — — — EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND NON -REACTIVE. 9. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 10. ALL FASTENERS TO BE #12 X 3/4" OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH ALL APPLICABLE FEDERAL,STATE, AND LOCAL CODES. 11. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION. 12. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. at. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 13. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE UNIT OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY NEXT TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 14. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. DOOR * ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION - DESIGN INFORMATION: HARK Qw W x H (in.) ZONE DESIGN PRODUCT MODEL APPROVAL PRESSURE MULLION MULLION 511E PRESSURE (psf) APPROVAL (�N APPROVAL (In.) 1a (1) 3).00x3].00 4 +52.4]/-65.8] SERIES SH-700 ALUMINUM SINGLE HUNG 1)-0630.O1lb WINDOW•60/-80 3).00x37.00 4 +52.9)/-65.6] N17�630.08 SERIES SH-]00 ALUMINUM SINGLE HUNG(I) 1]-0630.O1 1x2.]5 x0.3]5 WINWW-80/-00 2 (I) 10fi.00x B0.00 0 +4].83/-61.9] PGT SERIFS])0-HP SLIDING GLASS DOOR b0/-T00 WA WA 3 I I10.00x S0.00 9 +49.69/-63.59 HR-710 HORIZONTAL ROWNG WINDOW M3.8/-6).8 WA WA 4 (1) 36.ODx3].00 9 +52.4)/-65.8) SERIES SH-700 ALUMINUM SINGLE HUNG .80/40 WA WA WINDOW DRAWING NOTES: FILE COPY LEVEL OF ALTERATION I ONLY. IF LEVEL OF ALTERATION IS DIFFERENT, THIS Y DOOR PRODUCT SHALL EXIT ONLY TO METING BALCONIES WAH IXLSTING 42' HIGH APPROVED GUARDS WHICH SHALL NOT MUST HAVE MINIMUM SILL HEIGHT OF 24 INCHES. OPERABLE WINDOWS WITH SILL HEIGHTS LOWER THAN 42 INCHES THAT DO NK L BENN RDO, P.E. PE0046549 aHUP, vsvwFAu rmv Iptgl M. 0, P.E. 82328 ICE: IF THIS SHEET DOES CONTAIN ANgRIGINAL NWAS G[NEER SEA' HERE IPA L VATURE 1LEET I, THIS HT 15 OE A DIGITALLY V��qQ SAA-REMAIN IN F'Pn RN)AT, & PRINTED �I[�O THIM DOCUMENT :`NOT CONSIDERED SIGCE 1 SEALED. IFTHERE IS NO RAL SIGNATURE ON SHEET 1 THIS SHEET DOES NOT RAIN AN ENGINEER'S 31ML SIGNATURE & SEAL, y to N 0 Z 'v o Ul T® -m goo LLlll� mum W TiI O � w a (A y1,� LLN xwae _Wry• wLUU 'zQF /Z�LI w U': xs U ~>Q0-cwa �Q W wL70 Tome WWR4 anizww �� W n.ZU m0 U. U) W diw OLU to W w to ti0 U Z_ En _1 Q w w O z U) w LL 002 LLI 0 o Q Z Z 0 w Z aaU) fUri EEA n m Li. C3On, Z 0 U) �" L9 LU F- MIR F��GD 1 18-6456 1 FLOOR PLAN AND UNIT LAYOUT PRODUCTS HAVE BEEN CALCULATED USING WIDTH - HEIGHT/ 3 (EFFECTIVE AREA a H•H/3)