HomeMy WebLinkAboutBUILDING SCHEMATICBASIC WIND SPEED = 170 mph RISK CATEGORY 11 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, PEAK ROOF I' LESS THAN 7'-9� L- GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3' L•- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSMKE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.SD. ULTIMATE A.S.D. ULTIINTE A.S.D. ULTIMATE ASD. 0' - 15, 76.4 45.8 102.4 67.4 73.0 438 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 1076 64.6 76.6 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 671 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-3O' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4 974 58.4 > 30-40' 90.7 54.4 121.4 72.8 86.6 2.0 113.3 68.0 81.1 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 11 Z7 70.6 84. j - 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 65.9 J BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (P S F.) FOR ASCE 7-to - PEAK ROOF HEIGHT GREATER THAN 60 FEET ak BASIC WIND SPEED = 170 mph RISK CATEGORY 9 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF C*• LESS THAN 12-3" 1' GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.SD. ULTIMATE A.SD. ULTIMATE A.S.D. ULRMA7£ A.S.D. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > s0' - too' 973 58.4 178.4r 4 89.7 53.8 1579 94.7 > 100' - 120' 100.5 60.3 184.25 92.5 55.5 163.0 97.8 120"'- ig0y 103.2 6�1.9 189.25,� 95.1 57.1 167.4 100.4 > 140' - tso' 105.E 63.4 193.E 97.3 58.4 171.3 102.8 > 160' - 180' 107.8 64.7 19Z66 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.25 105.2 63.1 185.1 1I1.1 > 250' - 300' 11Z8 70.1 216.06 108.5 65.1 1911 114.7 > 300' - J50' 121.0 72.5 221.91 111.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 227. 1 1t4.1 68.5 200.9 120.5 400' - 450' 126.4 75.8 231.81 116.5 69.9 205.1 123.1>450' - 500' 128.8 773 236.17 118.E 71.2 208.9 125.3 N07E5: 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, 84SED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & DIPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORM4770M FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE 77ME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). ST. LUCIE COUNTY BUILDING D ION REVIEWED FORCOMPLIANC �_,, � PLANS AND PERMIT MUST BE KVTON JOB SITE OR NO INSPECfION(S) W L E MADE oI$' ....... p Z� a• No.44167 -o -ti STATE Of SCANNED BY St. Lucie County * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. r* L = STORM PANEL LENGTH, ACCORDION SHUTTER BADE LENGTH OR BANANA SHUTTER HEIGHT. r** PRODUCTS WHICH BEAR A M14MI-DADS COUNTY OR A STATE OF FLORIDA APPROVAL P�LoEApf to Gvkl FILE COPY CONCEALED FASTENERS OR ATTACHM6NTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD 2077 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES I ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & BAL14MA SHUTTERS *** DRAWN BY RISK .CAT. 11 SLOGS 08109117 L E C O N e. WIND PRESSURE CHART DATE STING & ENGINEERING -COMPANY BASIC WIND SPEED = 170 mph tn. 51 5T•. J VR GIRODI$ a M166 EXPOSURE D, Kd = 0.85 17- 194 DRAWING No SHEET I OF t