Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
} 9 Right -Suite® Universal 2017 Short Form Job: wri htsoft UNIT ONE SCANNED Byte: May 08, 2018 BY St. Lucie County Projeci Information For: 3500 S US #1, Wildar Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI Htg Clg Htg Clg Outside db (°F) 42 90 Inside db (°F) 70 75 Outside RH N - 60 Inside RH N - 50 Outside wb (°F) - 78 Inside wb (°F) - 63 Daily range (°F) - 15 Design TD (°F) 28 15 Moisture diff. (gr/lb) - 61 Heating Equipment Cooling Equipment Make Make TRANE Model Model TTA0724 Type Elec strip Type Split AC Efficiency 100 EFF COP / EER / SEER 11.5 Heating Input 13.1 kW Sensible Cooling 57.0 MBtuh Heating Output 44.7 MBtuh Latent Cooling 19.0 MBtuh Humidifier 9.4 gpd Total Cooling 76.0 MBtuh Leaving Air Temp 96.1 °F Leaving Air Temp 55.0 °F Actual Heating Fan 1559 cfm Actual Cooling Fan 2400 cfm Equipment Location UNIT ONE System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area ft' I Heat Loss I Sensible Gain I Latent Gain I Htg cfm I Clg cfm I Time bath 1 88 2017 1612 230 94 110 Jul 1700 LOT bath 2 76 1775 1152 190 83 92 Jul 1700 LDT a/h 12 13 0 0 0 0 Jul 1700 LDT open space 1 968 38278 35894 19947 1382 2197 Jul 1700 LDT storage 40 44 0 0 0 0 Jul 1700 LDT stairs 15 16 0 0 0 0 Jul 1700 LDT UNIT ONE 1199 42143 1 38659 1 20367 1 15591 24001 Jul 1700 LDT {� zaleJaF1s17:22: wrightsoft Right -Suite® Universal Page I ... A3500 S US#1 Duct redesigned -fort pierce.rup Calc=CLTD Front Door faces:E Right wrightsoft° $u ite® Universal 2017 Short Form pate: May 08, 2018 UNIT TWO By: For: 3500 S US #1, Wildar Golf Carts and Trailers 3500 S US #1, Fort Pierce, A Htg Clg Htg Clg Outside db (°F) 42 90 Inside db (°F) 70 75 Outside RH N - 60 Inside RH N - 50 Outside wb (°F) - 78 Inside wb (°F) - 63 Daily range (°F) - 15 Design TD (°F) 28 15 Moisture diff. (gr/lb) - 61 Heating Equipment Cooling Equipment Make Make TRANE Model Model TTA0724 Type Elec strip Type Split AC Efficiency 100 EFF COP / EER / SEER 11.5 Heating Input 13.6 kW Sensible Cooling 57.0 MBtuh Heating Output 46.5 MBtuh Latent Cooling 19.0 MBtuh Humidifier 13.1 gpd Total Cooling 76.0 MBtuh Leaving Air Temp 93.0 °F Leaving Air Temp 55.0 °F Actual Heating Fan 1836 cfm Actual Cooling Fan 2400 cfm Equipment Location UNIT TWO System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area fta I Heat Loss I Sensible Gain I Latent Gain I Htg cfm Clg cfm I Time SHOW ROOM 1224 45286 41921 26832 1730 2223 Jul 1700 LDT A/H2 16 17 0 0 0 0 Jul 1700 LDT hall 225 1152 1674 564 49 102 Jul 1700 LDT bath 4 48 705 595 120 29 37 Jul 1700 LDT bath 3 48 705 595 120 29 37 Jul 1700 LDT UNIT TWO 1561 47866 44786 27637 1836 2400 Jul 1700 LDT 2018-JuF19 17:22A1 wrightsofr Right -Suite® thiversal 201717.0.17 FEU06570 page 2 ... A3500 S US#1 Dud redesigned -fort pierce.rup Cale =CLTD Front Door faces: E wrightSoft' RightSuite® Universal 2017 Load Summary UNIT ONE Job: Date: May 08, 2018 By: Project Informatid"n' For: 3500 S US #1, Wildar Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI Zone_000LING.LOAD_.:_---��_,_..._ 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 60 % MoistDiff. 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 8637 - 3. TRANSMISSION GAINS Sensible 10221 - Walls: 2789 - - Glass: 3355 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 4077 4. INTERNAL HEAT GAIN Sensible Latent 7255 2890 Occupants: 3612 2890 - - Lights: 3643 - Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 194 3100 8098 6. SUBTOTAL: Space load Sensible Latent 29213 10988 Envelope 29213 10988 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 4855 - 8. SUBTOTAL: Space load + supply duct 34068 Actual cfm: 2400 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 225 3590 9379 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 1000 - 12. TOTAL LOADS ON EQUIPMENT 38659 20367 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 14072 Walls: 4032 - Glass: 6478 - Doors: 0 - Partitions: 0 - Floors: 2050 - Ceilings: 1512 - 15. INFILTRATION: Outside air cfm: 384 11827 16. SUBTOTAL: Spaceload 25899 Envelope 25899 - Less external 0 - Less transfer 0 Redistribution 0 - 17. SUPPLY DUCT: 5137 18. VENTILATION: Make-up air cfm: 225 6909 19. HUMIDIFICATION 3445 Piping 0 20. RETURN DUCT 753 21. TOTAL HEATING LOAD ON EQUIPMENT 42143 wrightSOft201&Jul-0Jul17:22: RighFSuite® Universal 201717.0.17 r6U06570 I page ... J13500 S US #1 Dutl redesigned -fort pierce.rup Cale= CLTD Front Door faces: E wrightsoft' Right -Suite® Universal 2017 Load Summary UNIT TWO Project Information For: 3500 S US #1, Wilder Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI Job: Date: May 08, 2018 By: Zone:�2, T_T1No: 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 90 OF RH: 60 % MoistDiff: 61.5 gr1lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 2392 Glass: 4890 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 5308 4. INTERNAL HEAT GAIN Sensible Occupants: 4567 Lights: 4973 Motors: 0 Appliances: 0 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Spaceload Sensible Envelope 40048 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 2400 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 15 OF Mult: 1.0 Ins.wb Sensible 13276 12591 Latent 3654 0 290 Latent 15777 0 20 284 9540 4641 40048 165 40212 4540 0 34 44786 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 16675 Walls: 3348 - Glass: 9444 - Doors: 0 Partitions: 0 Floors: 1915 Ceilings: 1969 - 15. INFILTRATION: Outside air cfm: 565 17399 16. SUBTOTAL: Spaceload 34074 Envelope 34074 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 211 18. VENTILATION: Make-up air cfm: 284 8736 19. HUMIDIFICATION 4814 Piping 0 20. RETURN DUCT 31 21. TOTAL HEATING LOAD ON EQUIPMENT 47866 63 OF Latent 3654 12124 15777 11859 27637 2018-Jukl9 17:22:41 wrightsoft Right-SuiL4 Lhivemal 20l7l7.0.17 F6L06570 Page 2 ... M500S US#1 Dud redesigned -fort pierce.rup Cale =CLTD Front Door faces:E wrightsoft Duct System Summary UNIT ONE For: 3500 S US #1, Wilder Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1559 cfm Job: Date: May 08, 2018 By: Cooling 0.10 in H2O 0 in H2O 0.10 in H2O 0.061 / 0.039 in H2O 0.038 in/100ft 2400 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk bath c 1578 94 110 0.044 6.0 Ox0 VIFx 23.6 115.0 st4 barn 2 c 1317 83 92 0.045 6.0 Ox 0 VIFx 20.3 115.0 st4 open space 1 c 6276 276 439 0.045 12.0 Ox 0 VIFx 20.6 115.0 st4 open space 1-F c 6276 276 439 0.038 12.0 W 0 VIFx 41.6 120.0 st3 open space 1-H c 6276 276 439 0.039 12.0 Ox 0 VIFx 37.0 120.0 st3 open space 1-1 c 62761 2761 439 0.045 12.0 Ox 0 VIFx 19.2 115.0 st4 open space W c 62761 2761 439 0.045 12.0 Ox 0 VIFx 19.6 115.0 st4 a °°Supply.Tru"nk°DetaH Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 553 879 0.038 629 16.0 0 x 0 VinlFlx st4 Peak AVF 1007 1521 0.044 861 18.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matt Trunk rb4- - -- Ox 0. 829 1318 104.0 0.038 944 16.0 ax 0 VIFx rb1 Ox0 730 1082 0 0 0 0 Ox 0 VIFx Bold/italic values have been manually overridden 2018.Jul-19 17:22:41 i t wrightsoft° Bight -Suite® Ur ivemal 201717.0.17 PSU06570 Page 1 ... A3500 S US #1 Dud redesigned -fort pierce.rup Cale= CLTD Front Doorfaces: E wrightsofV Duct System Summary UNIT TWO For: 3500 S US #1, Wildar Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1836 cfm 258 ft Job: Date: May 08, 2018 By: Cooling 0.10 in H2O 0 in H2O 0.10 in H2O 0.066 / 0.034 in H2O 0.039 in/100ft 2400 cfm Supply.B'ran;ch Detail -Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk SHOW ROOM c 6230 288 370 0.047 12.0 0X 0 VIFx 26.4 115.0 st1 SHOW ROOM-B c 6230 288 370 0.042 12.0 OX 0 VIFx 42.5 115.0 st5 SHOW ROOM-C c 6230 288 370 0.049 12.0 Ox 0 VIFx 20.3 115.0 st1 SHOwROOWD c 6230 288 370 0.046 12.0 Ox 0 VIFx 29.3 115.0 st1 SHOW ROOM-H c 6230 288 370 0.050 12.0 OX 0 VIFx 15.8 115.0 st1 SHOWROOM-1 c 6230 288 370 0.045 1,2 Ox 0 VIFx 32.0 115.0 sty ham C 629 29 37 0.039 4.0 Ox0 VIFx 34.9 135.0 st5 bath4 C 629 29 37 0.045 4.0 Ox0 VIFx 32.5 115.0 st5 hall c 1721 49 102 0.044 6.0 0x 0 VIFx 27.0 122.0 st5 Supply°Trtnk.Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 683 918 0.039 658 16.0 0 x 0 VinlFlx st2 st1 Peak AVF 1153 1482 0.046 839 18.0 0 x 0 VinlFlx st2 Peak AVF 683 918 0.039 658 16.0 0 x 0 VinlFlx Bold/italic values have been manually overridden 2018-Jul-1917:22:41 wrightsofr Right -Suite® Universal 201717.0.17 FSU06570 Page 2 ... J19500 S US#1 Dud redesigned -fort pierce.rup Calc=CLTD Front Door faces: E Rd6rri'Brancfi'Defa l};Tabie Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox0 865 1111 88.2 0.039 796 16.0 a( 0 VIFx rtl rb3 Ox0 971 1289 87.2 0.039 654 19.0 Ox 0 VIFx rtl ° Return-yrunk petail'Table "w Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk 0:1 Peak AVF 1836 2400 0.039 604 27.0 0 x 0 VinlFlx Soldfifalic values have been manually overridden 2018-Jul-19 17:22.41 Wrightrsoft Fight -Suite® Universal 201717.0.17 MLID6570 Page 3 ... M500S US#1 Dud redesigned -fort frierce.mp Calc=CLTD Front Door faces:E wrightsoft° Static Pressure and Friction Rate UNIT ONE Project Information For: 3500 S US #1, Wilder Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI Job: Date: May 08, 2018 By: Heating Cooling (in H2O) (in H2O) External static pressure 0 0.10 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0 0 Return grilles 0 0 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0 0.10 Total Supply Return (ft) (ft) Measured length of run -out 23 34 Measured length of trunk 19 0 Equivalent length of fittings 120 70 Total length Total effective length Supply Ducts Return Ducts Supply Return Heating (in/100ft) 0 0 4AD=60, 11M=20, 11G=5, 1A=35: TotalEL=120 5D=40, 6M=20, 11G=5, 11G=5: TotalEL=70 162 104 266 Cooling (in/100ft) < 0.06 0.038 < 0.06 < 0.06 0.038 < 0.06 2018-Jul-19 17:22:41 wrightsoft• Rghl-Sulk® Universal 201717.0.17 PSLU6570 Page 1 ... J13500 S US 01 Dua redesigned -fort pieme.mp Calc=CLTD Fmnt Door faces:E 4w + wrightsoft• Static Pressure and Friction Rate UNIT TWO Project Information For: 3500 S US #1, Wildar Golf Carts and Trailers 3500 S US #1, Fort Pierce, FI Job: Date: May 08, 2018 By: Heating Cooling (in H2O) (in H2O) External static pressure 0 0.10 Pressurelosses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0 0 Return grilles 0 0 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0 0.10 Total Effective Length Supply Return (ft) (ft) Measured length of run -out 19 21 Measured length of trunk 16 2 Equivalent length of fittings 135 65 Total length 170 88 Total effective length 258 Supply Ducts Return Duds Friction Rate Heating (in/100ft) 0 < 0.06 0 < 0.06 Cooling (in/100ft) 0.039 < 0.06 0.039 < 0.06 I_ Fitting Equivalent Length Details Supply 4AD=60, 11M=20, 11A=20, 1A=35: TotalEL=135 Return 6M=20, 11G=5, 5D=40: TotalEL=65 2018-Jul-19 17:22:41 wrightsoft' Right-SureS Lhiveisal 201717.0.17 PSU06570 Page 2 ... JX35005 US#1 Duct redesigned -fort Perce.rup Cale -CLTD Front Door taces:E