HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
230D Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: LIBERTY TIRE RECYCLING
Project Address: 9675 RANGE LINE ROAD, PORT ST. LUCIE, FLORIDA 34987
MIL
Permit #: 18080418 Occupancy Type: COM Construction Type: FOUNDATION DESIGN
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition SCANNED
o Any accessory structure requiring a building permit BY
o Any non-residential structure. St. Lucie Count
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code 201�Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed _Partially Enclosed _Open
3. Risk Category: X 1 II _III IV Exposure Category: B X C D
4. Design Wind Velocity 145 mph ASO X LRFD End Zone Width: IT
5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
\WMWLp['I/�earing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes
a&&Ie a S� , /K AAL CERTIFICATION STATEMENT:
eQ`/(c�fitify tha td', g�' St of my knowledge and belief, the attached plans & specifications have been designed to
coNpiy744 11the 'applicable structural portions of the building codes currently adopted and enforced by St. Lucie
'a County* I also certi fttRt structural elements depicted on these plans provide adequate resistance to the design
S fore0Fred: ;
AHMADREZA SEDAGHAT
rs,•.___.�a \� Print Name Cent # & Co. Cert Auth.
Signature, Date, and Seal FLORIDA ENGINEERING AND DESIGN INC.
Company Name &Address
Revised 07/25/2014 NOV - 3 20181 U�
1".