Loading...
HomeMy WebLinkAboutPROJECT SUMMARYShort Desc: POLARIS Owner: Addressl: U.S. HWY. 1 Address2: PROJECT SUMMARY Description: POLARIS City: State: Zip: Type: Office Class: Jurisdiction: ST LUCM COUNTY, ST LUCM COUNTY, FL (661000) Conditioned Area: 600 SF Conditioned & UnConditioned Area: No of Stories: 1 Area entered from Plans Permit No: 0 Max Tonnage If different, write in: FT. PIERCE FL 0 New Finished building 600 SF 0 SF 2.4 SCANNED BY St. Lucie County EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page I of 7 Component Design Criteria Result Gross Energy Cost (in $) 425.0 452.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS No Entry PIPING SYSTEMS No Entry Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@) Fla/Com-2010. Section 506.4 Compliant Software, Effective Date: March 15, 2012 4/14/2015 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date: N /s%s Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: / gno7' Plumbing Designer: Reg No: (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page 3 of 7 Project: POLARIS Title: POLARIS Type: Office Building End Uses 1) Proposed 2) Baseline Total 27.20 3610 $425 $565 ELECTRICITY(MBtu/kWh 27.20 36.10 /$) 7956 10570 $425 $565 AREA LIGHTS 1.30 6.90 383 2021 $20 $108 MISC EQUIPMT 9.00 9.00 2637 2637 $141 $141 PUMPS & MISC 0.10 0.10 19 22 $1 $1 SPACE COOL 6.70 9.20 1967 2699 $105 $144 SPACE HEAT 0.30 0.80 88 240 $5 513 VENT FANS 9.80 10.10 2862 2951 $153 $158 Credits Applied: None PASSES Passing Criteria = 452 Design (including any credits) = 425 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 75.1% EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page of External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: POLARIS Title: POLARIS Type: Office (WEA File: FL_ST_LUCIEE_CO_EVM.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Pr0Zol Sp 1 16 O1Fce -Open Plan 600 1 1 PASSES PASSES Project: POLARIS Title: POLARIS Type: Office (WEAFile: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Efi Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 28600 20.00 12.23 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 28000 10.00 7.70 PASSES (Heating Mode) Split System < 65000 Btu/h Cooling Capacity Air Handling System Air Handler (Supply) - 1000 0.80 0.82 PASSES -Supply Constant Volume PASSES EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page 5 of Plant Compliance Description Installed Size Design Min Design Min Category Camp No Eff Eff IPLV IPLV Hance None -::::1j Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss Hance None Piping System Compliance Category Pipe Din Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] M SF.F] None EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page 6 of 7 tt: POLARIS POLARIS Office LFile: FL_ST_LUCIE_CO_INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 506.4.2 Input Report Print -Out from EnergyGauge F1aCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows & Doors 502.3.2 Glazed swinging entrance & revolving doors: max. 1.0 cfn/ft2; all other products: 0.3 cftn/112 Joints/Cracks 502.3.3 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 502.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat (exceptions); separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply & exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s) tested & balanced. Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water. Ih accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2. Heat trap required. Swimming Pools 504.7 Vapor -retardant or liquid cover or other means proven to reduce heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit® Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 4/14/2015 Page 7 of 7 EnergyGauge Summit® v5.00 Proiect Information Project Name: pOLARIS Orientation: North Project Title: POLARIS Building Type: Office Address: U.S. HWY. 1 Building Classification: New Finished building State: FL No.of Stories: ] Zip: 0 GrossArea: 600 SF Owner: Zones No Acronym Description Type Area [sf] Multiplier Total Area [sfl 1 PrOZol Zone 1 CONDITIONED 600.0 1 600.0 ❑ Spaces No Acronym Description Type Depth [ft] Width Height Multi IN [ft] plier Total Area [sf] Total Volume lcf] 4/14/2015 EnergyGauge Summit® v5.00 1 -PrOZol ' ron 1 PrOZo1Sp1 Zo0Sp1 Office -Open Plan 20.00 30.00 9.00 1 600.0 5400.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 5 25 125 Manual On/Off 1 ❑ Walls No Description Type Width H (Eflec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/cf] [h.s£F/Btu] [Btu/sf.F] In Zone: PrOZol I PrOZolWal Metal 20.00 9.00 1 180.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+R1 2 Pr0Zo1Wa2 IBatt/5/8"Gyp Metal 30.00 9.00 1 270.0 East 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 3 PrOZOlWa3 1Batt/5/8"Gyp Metal 30.00 9.00 1 270.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl IBatt/5/8"Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: PrOZol In Wall: EAST I PrO ol%2W1l User Defined No 0.6000 0.42 0.39 20.00 7.00 1 140.0 El 2 Pr0ZOlWa2W12 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 01 4/14/2015 EnergyGauge Summit® v5.00 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sE F] [lb/cf] [Btu/sE F] [h.sEFBtu] In Zone: In Wall: El Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R Value [ft] Ft] plier Isf] [deg] [Btu/hr. SE F] [Btu/sE F] [Ib/cf] [h.sEF/Btu] In Zone: PrOZol 1 PrOZolRfl Mtl Bldg Roof/R-19 20.00 30.00 1 600.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Ef ec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] ISf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sE F] Ob/cf] [h.sEFBtu] In Zone: PrOZol 1 PrOZolFl1 1 ft. soil, concrete 20.00 30.00 1 600.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad 4/14/2015 EnergyGauge Summit® v5.00 Systems Pr0Sy1 System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 28600.00 20.00 8.00 28000.00 10.00 1000.00 0.80 ❑ ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit3Cap.Unit UP Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sVft/No] Control Type Wattage M El _J1 Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] 4/14/2015 EnergyGauge Summit® v5.00 Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btu/b.sf.Fl ASHULSg1C1rA11 User Defined 1 1.2500 0.8200 0.7600 ❑ Frm ASHULDblTntW User Defined 2 0.6000 0.4200 0.3900 ❑ d-Vy-Fg firm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtul IN [Btu/h.ft.F] [Ib/cQ [Btu/lb.F] 1811 MatI187 UYF OR PLAS No BOARD,1/2IN 178 MatI178 CARPET W/RUBBERPAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 MatI48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc+RII Batt No 10.4179 0:2917 0.0280 7.11 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.]] [Btu/sCFI Db/ctl [h.sf.FBtul 1055 Metal siding/2x4@24"+RI1Batt/5/8"Gyp No No 0.09 1.07 19.38 10.9 ❑ 4/14/2015 EnergyGauge Summit® v5.00 5 Layer Material Material Thickness Framing No. [ft] Factor 1 4 Steel siding 0.0050 0.000 ❑ 2 271 2x4@24" oc+RII Batt 0.2917 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [Ib/cf] [h.sEF/Btu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [lb/cf] [h.sEFBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 4/14/2015 EnergyGauge Summit® v5.00 6 Ri ht-Suite® Universal 2015 Short Form ate �- wrightsoft• � Date: Date: Sep 03, 2074 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772r16&6796 Email: QUIIXCALCS@AOLCOM rroject Intormation For. POLARIS FT. PIERCE, FL Htg Clg Htg Clg Outside db (OF) 42 90 Inside db (OF) 70 75 Outside RH M - 59 Inside RH (%) - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 15 Moisture diff. (gr/lb) - 61 Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Tem p Actual Heating Fan Elec strip 100 EFF 7.6 kW 26.0 MBtuh 10.9 gpd 96.3 OF 900 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static PressureAcross Fan Cooling Equipment Make Model Type COP/EER/SEER Sensible Cooling Latent Cooling Total Cooling Leaving Air Tem p Actual Cooling Fan Entire House PEAKCV PACKAGE 0 % 0 in H2O MITSUBISHI Split AC 20.0 19.6 MBtuh 8.4 MBtuh 28.0 MBtuh 55.0 OF 900 cfm NAME Area Heat Sensible Latent Htg Clg Time ft' Loss Gain Gain cfm cfm INSIDE ROOM 600 26040 19080 9023 900 900 Jul 1600 LDT WAREHOSUE 1850 0 0 0 0 0 Jul 1600 LDT Entire House 2450 26040 19080 9023 900 900 Jul 1600 LDT ft^ ht wri so2015-Apr-1510:20:37 9 RightSutle® UnNersal 2015 15.0.02 RSU08101 Page 1 ... lck Cal=NDomments%WrigMmR WACIPOLARIS.mp Calc=CLTD Fmnt Worfam& N RightSuite® Universal 2015 Load Summary Job: -� wrightsofto W74REHOSUE By e: Sep 03, 2014 QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone 772-466-6799 Fax 77246645796 Email: 0Ul0(CALCS@ADL.COM •a r1111507F• For. POLARIS FT. PIERCE. FL Zone: .WAREHO,SUE__COOLING_LOAD__... 1. DESIGN CONDITIONS at Jul 1600 LDT Peak load at Jul 0100 LOT Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 59 % MoistDiff: 61.5 gdlb Mult: 0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 0 Walls: 0 - - Glass: 0 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 0 - - 4. INTERNAL HEAT GAIN Sensible Latent 0 0 Occupants: 0 0 - - Lights: 0 - Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 111 0 0 6. SUBTOTAL: Space load Sensible Latent 0 0 Envelope 0 0 - - Less external 0 - Redistribution 0 0 - 7. SUPPLYDUCT 0 - 8. SUBTOTAL: Space load + supply duct 0 Actual cfm: 0 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETURNAIR LOAD: Lighting + plenum (net) 0 - 11. RETURNDUCT 0 - 12. TOTAL LOADS ON EQUIPMENT 0 0 --- . ..�_ _ ._ HEATING. LOAD,_ 13. DESIGN CONDITIONS Mult: 0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 0 Walls: 0 - Glass: 0 - Doors: 0 - Partitions: 0 - Floors: 0 - Ceilings: 0 - 15. INFILTRATION: Outside air cfm: 167 0 16. SUBTOTAL: Space load 0 Envelope 0 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCF: 0 18. VENTILATION: Make-up air cfm: 0 0 19. HUMIDIFICATION 0 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ONEQUH'MENT 0 hYSOfC 2015-Apr-1510:20:37 Wrl 9 RightSutte® Universal 201515.0.02 RSU06101 Page 2 ...Idc CalaXWcuments\Wrightsoft INACIPOLARIS.rup Cale =CLTD Frord Door ferns N