HomeMy WebLinkAboutSUBMITTED PAPERS (2).;,--D E&T DUNKELBERGER ENGINEERING & TESTING, INC. Project Name: Proposed Guardian Self-Sto�' �J I Report Date: 02-05-02 y Port St. Lucie, Florida /- C lent Name: PSL. Ltd. �1D 2a�2 ' 1800 Bering Drive, Suite 10 0 F Project No.: 01-10-I 110 Houston, Texas 77057 = rubllC WOfks Date Tested: 01-22-02 gt, I Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 4 (Sheet I of 3 Laborator e Proctor Field Tests Test No. Probe Depth in Maximum. Dry Density c Optimum -- Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 113.8 9.2 114.3 10.0 95 100+ Pass 2 12 113.8 9.2 113.6 --- 10.2 95 99.8 Pass 3 12 113.8 9.2 112.8 --- 10.6 95 99.1 Pass 4 12 113.8 9.2 1 1 1.3 1 - - - 9.3 95 97.8 Pass 5 12 1 13.8 9.2 1 13.3 - - - 9.9 1 95 99.6 Pass 6 12 113.8 9.2 112.0 10.9 95 98.4 Pass 7 12 1 13.8 9.2 109.5 - - - 9.8 95 96.2 Pass 8 12 113.8 9.2 110.3 --- 10.9 95 96.9 Pass I ype of Field Density "1'esl: 0 AS"I M 1) 1556 (X) AS'I'M 1) 2922 O ASTM D 2937" Minimum Required Compaction Based on: (X) AASI ITO *1*-180 (ASI'M D 1557) O AASI 1-10 '1 -99 (ASfM I) 698) Compaction percent estimated Gum cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test location: Building E 1 1 15.5 Northwest corner of buildin ad 2 1 15.5 Northeast corner of building ad 3 1 15.5 Southwest corner of building ad 4 1 15.5 Southeast corner of building ad 5 1 15.5 60' east and 50' south of northwest comer of pad A 6 1 15.5 70' east and 60' north of southwest corner of pad 7 1 15.5 95' south and 20' east of northwest corner of pad St 8 1 15.5 120' north and 30' west of southeast corner of pad Counh, Elevation Referenced to: (X) NGVD () MSL () Other Soil Type I Structural Fill 2 Final Grading Fill Mass Grading Fill Utility Backfill - Sanitary Utility Backfill - Water E Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: cc: Kimley-Horn, Inc. (Stuart), Mr. Mike Grezlka, P.E.... (1) Edgecomb & Associates. Mr. Clark Edgecomb... (1) Dooley & Mack Construction, Mr. Vince Gorman ... (1) Craig E. Dunkel FL Registration NA .E. 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 02-05-02 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1 1 10 Houston, Texas 77057 Date Tested: 01-22-02 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 4 (Sheet 2 of 3) Laborato Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 9 12 113.8 9.2 110.8 - - - 9.7 95 97.4 Pass 10 12 113.8 9.2 113.5 - 10.8 95 99.7 Pass 11 12 113.8 9.2 112.9 - - - 9.5 95 99.2 Pass 12 12 113.8 9.2 109.9 - - - 10.2 95 96.6 Pass 13 12 113.8 9.2 8.3 - - - 10.5 95 95.2 Pass 14 12 113.8 9.2 0.2 10.0 95 96.8 Pass 15 12 113.8 9.2 2.5 il --- 9.8 95 98.9 Pass 16 12 113.8 9.2 93 - - - 10.0 95 96.0 Pass I v c or Field Density lest: O ASI M I) 155fi (X) AS'I'M U 2922 O ASM U 2937 Minimum Required Compaction Based on: (X) AASI 1 ['0 *1-I80 (ASTM D 1557) O AASHTO'1'-99 (AS'IM D 698) 'Compaction percent estimated from cone penetrometer reading ohtained with Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test location: Building E 9 I 16.5 Northwest comer of build7ing pad 10 1 16.5 Northeast corner of building ad I 1 1 16.5 Southwest corner of buildin • pad 12 1 16.5 Southeast comer of building ad 13 1 16.5 60' east and 50' south of northwest comer of pad 14 I 1 16.5 1 70east and 60' north of southwest comer of pad 15 I 1 16.5 95' south and 20' east of northwest corner of pad 16 1 16.5 120' north and 30' west of southeast corner of pad Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2 Final Grading Fill 3 - Mass Grading Fill 4 Utility Backfill - Sanitary 5' Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Craig E. Dunkelberger FL Registration No. 4,0 F'El 5 2002 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 ®E&T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 02-05-02 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 01-23-02 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 4 (Sheet 3 of 3) Laborator Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c OptimumgDensity Moisture % Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Densit Test Result 1 12 113.8 9.2 --- 10.4 95 95.2 Pass 2 12 113.8 9.2 --- 9.5 95 98.1 Pass 12 113.8 9.2 - - - 9.8 95 98.0 Pass 4 12 113.8 9.2 110.3 --- 10.1 95 96.9 1 Pass 5 12 113.8 9.2 112.9 --- 10.8 95 99.2 Pass 6 12 113.8 9.2 112.1 --- 8.7 95 98.5 Pass 7 12 113.8 9.2 113.6 --- 9.8 95 99.8 Pass 8 12 113.8 9.2 109.9 - - - 10.6 95 96.6 Pass 'I ype of Field Uensilv'lest: O AStM D 1556 (X) ASI M D 2922 11 AS'I'M U 2937 Minimum Required C'ompa$:tion Based on: (X) AASI110 "1'-180 (AS1 M D 1557) O AASI ITD "1'-99 (ASfM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location: Building B 1 1 16.5 Northwest corner of buildin ad 2 1 16.5 Northeast corner of building ad 3 1 16.5 Southwest corner of building ad 4 1 16.5 Southeast corner of building ad 5 1 16.5 60' east and 50' south of northwest corner of pad 6 1 16.5 70east and 60' north of southwest corner of pad 7 1 16.5 95' south and 20' east of northwest corner of pad 8 1 16.5 120' north and 30' west of southeast corner of pad Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type I Structural Fill 2 • Final Grading Fill 3 . Mass Grading Fill 4 Utility Backfill - Sanitary 5, Utility Backfill- Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Craig E. Dunkelberger, FL Registration No. 4 FEB. - 5 21 lG 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 34 -5 State of Florida Board of Professional Engineers Authorization No. 6870 FIRE MARSHAL'S OFFICE St. Lucie County Fire District (561) 462-2312 • FAX (561) 462-2323 AUTOMATIC FAN SHUT DOWN REQUIREMENTS FOR AIR HANDLING SYSTEMS. 2400 Rhode Island Ave. Fort Pierce, FL 34950 The requirements for automatic fan shut down in air handling systems are the requirements of the Standard Mechanical Code, 1997 Edition, Chapter 4, Section 406, and the National Fire Protection Association, Life Safety Code NFPA 101. In determining which code to comply with, the following information is necessary. 1. A/C units make up a system and is referred to in the codes as an air handling system. 2. The NFPA Life Safety Code, Occupancy Chapters 8 through 31 references Heating, Ventilation, and air Conditioning and shall comply with Section 101-7-2 of the Life Safety Code. 3. - Section 101-7-2 requires air conditioning, heating, ventilating ductwork, and related equipment to be installed in accordance with NFPA 90A, Standard For The Installation Of Air Conditioning and Ventilation Systems, or NFPA 90B, Standard For The Installation of Warm Air Heating and Air Conditioning Systems. 4. NFPA 90A. Scope: This standard applies to all systems for the movement of environmental air in structures that: a.. Serves spaces over 25,000 cubic feet in total volume, or b. Serve buildings of Type III, IV, and V construction over three stories in height, regardless of volume. The construction types indicated are in accordance with NFPA 220. NFPA 90A. For the purpose of this standard, a space is considered as the entire building or a portion thereof separated from other portions of the building by fire resistance rated construction and whose environmental air does not mix with that of any other space. For spaces not exceeding 25,000 cubic feet in volume, reference the Standard Mechanical Code, Chapter 4, Section 406. 6. Spaces not exceeding 25,000 cubic feet in total volume shall be in accordance with the Standard Mechanical Code, 1997 Edition. 7. Automatic fan shut down requirements. NFPA 90A. a. Location: Smoke detectors listed for use in air distribution systems shall be located: 1.) Downstream of the air filters and ahead of any branch connections in air supply systems of greater than 2,000 cfin capacity. 2.) At each story prior to the connection to a common return and prior to any recirculation or fresh air inlet connection in air return systems over 15,000 cfin capacity and serving more than one story. Exception #1: Return systems smoke detectors are not required when the entire space served by the air distribution system is protected by a system of area smoke detectors. Exception #2: Fan units whose sole function is to. remove air from inside the building to outside the building. b. Function. Required smoke detectors shall automatically stop their respective fan(s) upon detecting the presence of smoke. Exception: Where the return air fan is functioning as part of an engineered smoke control system and a different mode is required. C. Installation. Listed duct type smoke detectors shall be installed in accordance with NFPA 72, National Fire Alarm Code. 1.) When an approved protective signaling system (fire alarm) is installed in the building the smoke detectors shall be connected to the protective signaling system in accordance with NFPA 72. Activation of any air distribution system smoke detector will cause a supervisory signal to be indicated at a constantly attended location or will cause an alarm signal. 2.) All detection devices used for the operation of smoke dampers, fire dampers, fan control, smoke doors, and fire doors shall be monitored for integrity in accordance with NFPA 72, 1-5.8 where connected to the fire alarm system serving the protected premises. 3.) When smoke detectors are installed in a building not equipped with an approved protective signaling system, the system shall a.) cause a visual and audible signal in a normally occupied area, and b.) smoke detector trouble conditions shall be indicated visually or audibly in a normally occupied area and shall be identified as air detector trouble. c.) The above signal requirements -can be annunciated with a simple remote test station with a sounder., Smoke detectors having power supplied separately from the signaling system (fire alarm) for the sole function of stopping fans do not require standby power. STANDARD MECHANICAL CODE Automatic Fan Shutdown Requirements: a. Systems serving buildings or spaces less than 25,000 cubic feet in volume shall comply with the requirements of the Standard Mechanical Code, Chapter 4, Section 406, 1997 Edition. b. Capacity greater than 2,000 cfin. Recirculating air systems with a fan capacity greater than 2,000 cfin shall automatically shut down by means of an approved smoke detector placed in the return air stream prior to any exhausting from the building or mixing with fresh air makeup. C. Capacity 2,000 cfm or less. Reciculating air systems with a fan capacity of 2,000 cfm or less, but serving an area used for egress, shall have automatic fan shutdown. This would be foyers, lobbies, stairways, corridors, and passageways. ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode island Avenue Telephone: 561-462-2312 Ft Pierce, FL • 34950 FAX: 561-462-2323 \lew Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Jurisdiction: SLC F.P.B.: See Below Occupancy: Guardian Self Storage Bldg. A - E and Officei Building Dept: See Below Address: 10725 S. US 1 Number of stories: 1. Contractor Dooley & Mack Constructors, Phone # 941-921-4636 Contractors Address: 2750 Stickney Point Rd. City: Sarasota State: Florida Zip Code: 34231 ArchitecttEngineer. Edgecomb & Associates, Inc. Phone # 713-523-2289 Building Owner: Review Date: 9/24/2001 Occupancy Type: Storage/Business/Residential Automatic sprinklers: Gross sq ft: See below Net sq ft: Occupant Load: Based On: Construction Type: SBCCI Type: IV unpNI unp NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. KNOX BOX IS REQUIRED ( ) Bldg. Dept. Permit Numbers: 21070537 21070532 21070527 21070522 21070517 21070542 REVISIONS REQUIRED KNOX KEY SWITCH REQUIRED (XX ) General: 1 1. A Knox key switch is indicated for the access gate. 2. Minimum fire extinguisher classification is 2A-10B:C i Bldg. A 7060 sq. ft. IV unp No revisions `- Fire Dept. Permit Numbers: B-01-218 B-01-219 B-01-220 B-01-221 B-01-222 B-01-223 An application can be obtained from this office. Bldg. B 26400 sq. ft. IV unp 1. The electrical room door shall have a door closer. 2. HVAC shutdown is indicated. See additional requirements. Bldg. C 26230 sq. ft, IV unp 1. The electrical room door shall have a door closer. 2. HVAC shutdown is indicated. See additional requirements. Bldg. D 21600 sq. ft. IV unp 1. Provide two additional portable fire extinguishers for Zone D-7 and D-8 at the exit doors. 2. The electrical room door shall have a door closer. 3. HVAC shutdown is indicated. See additional requirements. Bldg. E 26260 sq. ft. IV unp 1. The electrical room door shall have a door closer. 2. HVAC shutdown is indicated. See additional requirements. Rental Office/Manager's Residence 1900 sq. ft. VI unp - 1. The storage room shall be separated by 1-hr. construction with 3/4 hr. opening protectives including a self -closing device from the business occupancy. The opening protective for the separation between the residence and the storage room shall be 1 hour rated including a self -closing device. 2. Provide a portable fire extinguisher for the sales/reception area. 3. Bedroom windows shall comply with NFPA 101, 2000 Section 24.2.2.3 (c) Rescue windows shall have a minimum of 5.7 sq. ft. clear when opened. The dimensions listed in Section 24.2.2.3 only provide 3.3 sq. ti. clear opening. 4. HVAC shutdown is indicated. See additional requirements. Reviewed by: Date: 9/24/2001 polo s 37 CONSULTING ENGINEERS May 1, 2002 Mr. Robert Burnham Edgecomb & Associates, Inc. 2472 Bolsover, Suite 210 Houston, Texas 77005 (713/523-2289t,713/523-8827f) RE: Guardian Storage St. Lucie, Florida (SCA No.: 21070) Dear Mr. Burnham: It is our understanding from your fax dated April 25, 2002 that the contractor did not install the vertical reinforcing at the exterior masonry walls and pilasters for Building A of the referenced project. This situation may be remedied by drilling and epoxy anchoring rebar dowels with six inch minimum embedment into the existing concrete. If you have any questions, please call. Sincerely,, Brad L Crane, P.E- BLC/sh CORPORATE OFFICE 10101 Southwest Freeway Suite 600 -Houston, Texas 77074-1126 713/779-7252 1.800-422.7252 FAX. 713/779.1173 im@scahouston.com www.scaengineers.com { LOUISVILLE, EENTUCKY 502/426-6789 ORLANDO, FLORIDA 407/893-6200 IVE MAY St Lucie County Public Works ..A-DE&T DUNKEL,BERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REIVJKT Project Name: GP_rt Slue uardianiSelf-Stor�ageD 5� Report Date: 12-20-01 Port St. Lucie, Florida ' Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 1A ^ 3 20�2 Project No.: 01-10-1110 Houston, Texas 77057 ,A �- d ��- Date Tested: 12-12-01 echnician Initials: SM Attn: Mr. John C. West, President k1k, toe �)�� ro ress Report No.: 3 (Sheet 3 of 6 LabIProctor Field Tests Test No. Probe Depth in MaxiOptimum Dry DMoisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum DensityResult Test I 12 113.8 9.2 109.4 - - - 6.1 95 96.1 Pass 2 12 113.8 9.2 --- 40 --- 95 95 Pass 3 12 113.8 9.2 40 --- 95 95 Pass 4 12 113.8 9.2 --- 30 1 --- 95 95 Pass 5 12 113.8 9.2 108.6 - - - 5.0 95 95.4 Pass 6 12 113.8 9.2 --- 40 --- 95 95 Pass 7 12 113.8 9.2 --- 40 --- 95 95 Pass 8 12 113.8 9.2 --- 30 --- 95 95 Pass Type of Field Density Test: O AS'rM D 1556 (X) ASTM 1) 2922 O As-rM D 2937 Minimum Required Compaction Based on: (X) AASFITO T-180 (AS'rM D_1557) l) AASHTO T-99 (AS'rM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil T Elevation Test Location 1 1 16.5 Northwest comer of pad building C 2 1 15.5 Northwest corner of pad building C 3 1 14.5 Northwest comer of pad building C 4 10 13.5 Northwest corner of pad building C 5 1 16.5 Northeast comer of pad building C 6 1 15.5 Northeast corner of pad building C 7 I 14.5 Northeast comer of ad buildingC 8 10 13.5 Northeast comer of pad building C Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Stripped Grade cc: U Craig E. Dunkelberg P.E. FL Registration N 9932 U 3 1 2f ail 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 - t D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 12-20-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 12-12-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 3 (Sheet 4 of 6) Laborator i Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 9 12 113.8 9.2 112.6 - - - 10.2 95 98.9 Pass 10 12 113.8 9.2 --- 40 --- 95 95 Pass II 12 113.8 9.2 --- 40 --- 95 95 Pass 12 12 113.8 9.2 - - - 40 - - - 95 95 Pass 'type or Field Density Test 0 ASTM D 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASMfO T-180 (ASTM D 1557) O AASHTO'r-99 (ASTM D 698) 'Compaction percent estimated tom cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil TvDe Elevation Test Location 9 1 16.5 Southeast corner of pad building C 10 1 15.5 Southeast corner of pad building C I 1 1 14.5 Southeast corner of pad building C 12 10 13.5 Southeast corner of pad building C Elevation Referenced to: (X) NGVD ( ) NISL ( ) Other 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Stripped Grade cc: FU_raig E. Dunkelberg L Registration No. EC J I 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 3� State of Florida Board of Professional Engineers Authorization No. 6870 b t r- , D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 12-20-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1 110 Houston, Texas 77057 Date Tested: 12-13-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 3 Sheet 5 of 6 Test No. Probe Depth in Laborator Proctor Field Tests Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 113.8 9.2 109.0 --- 11.0 95 95.8 Pass 2 12 113.8 9.2 35 --- 95 95 Pass 3 12 113.8 9.2 --- 40 --- 95 95 Pass 4 12 113.8 9.2 --- 40 --- 95 95 Pass 5 12 113.8 9.2 110.1 - - - 11.5 95 96.7 Pass 6 12 113.8 9.2 - - - 40 - - - 95 95 Pass 7 12 113.8 9.2 --- 40 --- 95 95 Pass 8 12 113.8 9.2 --- 40 --- 95 95 Pass Type of Field Density'fest _ __ 0 A%TM D 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASHTO T-I8n (AS'1'M D 1557) O AASH'1'0'1'-99 (ASTM D 698) Compaction percent estimated rrom cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil TvDe Elevation Test Location: Building PadC 1 1 16.5 60' south and 60' east of northeast corner of pad 2 1 15.5 60' south and 60' east of northeast corner of pad 3 1 14.5 60' south and 60' east of northeast corner of pad 4 10 13.5 60' north and 60' west of northwest corner of pad 5 1 16.5 60' north and 60' west of northwest corner of pad 6 1 15.5 60' north and 60' west of northwest corner of pad 7 1 14.5 60' north and 60' west of northwest corner of pad 8 10 13.5 60' north, and 60' west of northwest corner of pad Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Stripped Grade cc: V Craig E. Dunkelb FL Registration I 1,1 r.0 .5 I 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. Project Name: Proposed Guardian Self -Storage Report Date: 12-20-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 12-13-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 3 (Sheet 6 of 6) Laborator r Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 9 12 113.8 9.2 109.0. - - - 12.2 95 96.2 Pass 10 12 113.8 9.2 - - - 35 95 95.0 Pass 11 12 113.8 9.2 - - - 40 - - - 95 95.0 Pass 12 12 113.8 9.2 40 - - - 95 95.0 1 Pass Type of Field Density Test 0 ASTM D 1556 (X) AS-1 M D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASII'1-0 T-180 (ASTM D 1557)- - -- O AASH'1-0 T-99 (ASTM D 698) Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 9 1 16.5 Southwest corner of pad building C 10 1 15.5 Southwest corner of pad building C I 1 I 14.5 Southwest corner of pad buildin • C 12 10 13.5 Southwest corner of pad building C Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course to Other: Stripped Grade cc: Craig E. FL Regi R P.E. 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (5 i 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 .DE&T DUNKELBERGER ENGINEERING & TESTING, INC. -Project Name: Proposed Guardian Self -Storage t Port St. Lucie. Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Houston, Texas 77057 Mr. John C. West, President APR 0 2 2002 Lucie county Publlc Repyate: Pl/rrojj((!4ct Nt� Date Tested: ician Initials: 03-20-02 01-10-I110 03-06-02 SM 6 (Sheet I of 3 Laborato Proctor Field Tests Test No. Probe Depth in Maximum Dry Density Optimum Moisture % Dry Density Cone Resistance' is Moisture "/o Minimum Required Compaction % Percent Maximum Density Test Result 1 12 113.8 9.2 115.0 - - - 9.8 95 100+ Pass 2 12 113.8 9.2 112.0 - - - 10.6 95 98.4 Pass 3 12 113.8 9.2 113.2 - - - 8.3 95 99.5 Pass 4 12 113.8 9.2 112.6 - - - 1 8.9 95 98.9 Pass 'Type of Field Uensity'Test: O ASTM D 1556 (X) ASTM 1)2922 1) ASTM D 2937 Minimum Required Compaction Based on: (X) AASIITO T-180 (ASTM D 1557) 1) AASHT0'I'-99 (ASTM U 698) 'Compaction percent estimated from cone penetrometer reading obtained,with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location: Building A 1 I 0-12 Southwest comer of building 2 I 0-12 75' north and 25' east of southwest comer 3 I 0-12 150' north and 10' east of southwest comer 4 I 0-12 Northeast corner of building Elevation Referenced to: () NGVD ( ) MSL Soil Type I Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade' 9 Base Course 10 Other: (X) Other Inches below top of final fill cc: Kimley-Hom. Inc. (Stuart). Mr. Mike Grezlka. RE .... (1) Edgecomb & Associates, Mr. Clark Edgecomb... (1) Dooley & Mack Construction. Mr. Vince Gorman ... (1) -raig E. Dunkelberg F&gtr'tion N�o/ 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6970 04/16/2002 10:39 3216770285 RICK DOOLEY MACK PAGE 05 0 REQUEST FOR 30. DAY TEMPORARY POWER RELEASE DATE: ST. LUCIE COUNTY :DLDG. & ZONING 23 DO VIRGINIA AVE FORT PIERCE, FL 34952-5652 PERMIT NUMBER: Ph. (561) 462-2165 � F f (� AX (561) 462-1148 UCPRO2�o70SZrl j E PERTY ADDRESS:2�OZ caw le Works THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTI.ICA'i POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO EX CEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Po:3cy, which is incorporated herein by reference. 3. AU conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing" have been fulfilled and the premises is ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL LIABILITIES AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE IWCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWERDN THE EVENT OF VIOLATION OF THIS AGREEMENT. OWNER Dooley & Mack Constructors, Inc. SIGNA ELECTRICAL CONTRACTOR SIGNATURE 04/16/2002 10:39 3216770285 RICK DOOLEY MACK PAGE 04 REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATE: (ZOO 'L PERMIT NUMBER: Z/0,70 V31 PROPERTY ADDRESS: ST. LUCIE COUNTY IILDG. & ZONING 23110 VIRGINIA AVE la2zS S //.r'i/ 7?p�p st Lie FL 34952-5652 (561)462-2165 (561)462-1148 vv 0 THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FORA PERIOD NOT TO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by :ill terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. All conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing" have been fulfilled and the premises is ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEM EMPLOYEES FROM ALL LIABILITIES AND CLAIMS, OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE WCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER IN THE EVENT OF VIOLATION OF THIS AGREEMENT. , n PSL Ltd dba Guardian Self Stora e OWNER ;IG/N,A- A Dooley & Mack Constructors, Inc. l�1/G�I�Grn/ Cl~O GENERAL CONTRACTOR SIGNATURE ELECTRICAL CONTRACTOR SIGNATURE 04/16/2002 10:39 3216770285 RICK DOOLEY MACK PAGE 03 REQUEST FOR 30 DAY TEMPORARY POWER 'RELEASE DATE: /D2 ST. LUCIE COUNTY BLDG. & ZONING 2300 VIRGINIA AVE FORT PIERCE, FL 34952-5652 PERMIT NUMBER: fl Q� FAX(561) 462 1148 ;Iczor!�Uo�lc P PROPERTY ADDRESS: /11 Works Osl fo THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO Eli CEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS 'FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. AB conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing' have been fulfilled and the premises is ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEM EMPLOYEES FROM ALL LIABILITIES AND CLAM i OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE INCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER IN THE EVENT OF VIOLATION OF THIS AGREEMENT. , n OWNER Dooley & Mack Constructc GENERAL CONTRACTOR SIGNATURE C� 04/16/2002 10:39 321677 RICK DOOLEY MACK PAGE 02 REQUEST FOR 30 DAY TEMPORARY POWER ILELEASE DATE: ST. LUCIE COUNTY 3LDG. & ZONING Z/ /b OZ 23 )0 VIRGINIA AVE FORT PIEIREE, FL 34952-5652 h. (561) 462-2165 PERMIT NUMBER: FIRE 7 Q 7 � (561) 462-1148 n /O qz- u L-P L AR 16 2002 PROPERTY ADDRESS: St, LU018 County Public Works THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO EX GEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction daring this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and condition of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. All conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing" have been fuL5lled and the premises is ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL LIABILITIES AND CLAIM:; OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE 124CURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER INTHE EVENT OF VIOLATION OF THIS AGREEMENT. e & Mack GENERAL CONTRACTOR SIGNATURE CC'O Jul 09 02 02:04p DAVIDSON INSULATION PSL 5G1 335 17,9 p.l ��r,;. - l 7 .. ... ✓--J-:.,.-./J..=,/.. J_-.�)✓ .,,��,..,/. �:�i J �...,;')J;Y v..l.i_ 1 � //,Uq C - �IJJ 0 CLIMATE PRO") FIBER GLASS BLO OL2002X. Your home has been professionally insul t d im = ire ;> a thermal resist a>< ceL°°' blis 7Orks guaranteed rYti r:, � Honfhrown'�as's N!that f \ ° 7 �jS" ! r „�(ai d a r 67 u5 /v Musa' --- 1 f '•; a71• RECORD OF INSTALLATION BLOWING WOOL BATES AND ROL.S THICKNESS AREA INSULATED it wmq CUNsntU(I'ION, IFV.MRQFn'. R-VALUE �< •r D rlrnzonT DEIm( OF PRE\nOUS 15 INSUTATION CrilINGB —IN. SQ. FI'. ! F.+` NIlimHER OF BAC,S LISED INg1E5 Fr wU/'�"�C AeH A INxumijq)A& ULSTIMATEn B-Vnl.ul( OP PREVIOUS INSULATION WN.IS —1N. SQ. Fr. c <'1 j� /" TuENus OF lNsulwnoN� 11rE(s)or PRLvwus ¢: INCHES INSULATION IN ATTIC IIDORS —IN. SQ. FE R-VAI.UI: OP 1NSUTATION —IN. SQ. IT. ., III IMATF PRO. RAI', WEIGHT.25 LR. NOMINAL R-VALUE MINIMUM THICKNESS BAGS PER 1000 SO. FT. MAXIMUM NET COVERAGE MINIMUM WEIGHT PER SO. FT. To oblarn an Installed Tlv number ofbnyn Conlent<of The errighl/ier isntdolin++ nwdnlioe f n 100051. f. of this bagslmukl sq. Jr. of inabdlrcl , sislanee .dlendd nod =I area should aat nor moor huu/alien, should (R) o(.' (e less then: be 1I (hen,: n a. than, not be kss dear, I 5R in. 7.0 142 sq, ft. 0.176 Ibs. 19 8Y. in. 12.5 79.9 sq. ft. 0.313 Ibs. 22 10 in. 14.6 68.4 sq. IL 0.365 Ibs. 26 11/+ in. 17.2 58.0 sq. ft. 0.431 lbs. 30 13 in. 20.0 50.0 sq. ft. 0.500lbs. 38 16Y in. 26.3 38.0 sq. ft. 0.659 Ibs. 44 18Y in. 30.5 32.8 sq. ft. 0.763 lbs. 50 20Y in. 35.5 28.2 sq. ft. 0.8861bs. 60 23Y in. 43.0 1 23.2 sq. ft. 1.076 Ibs. ;1,rit IDSON & ACO INSulAT'lot" Ws %` PORT f Y COMPANY F^ O }v5j3 6 1-10AIE BUILDER SIGNAT'UIU'. INC. DATE. G2 '14ONE DATH •NONE. W17 Johns Manville P,99)J Wrs Mannlh Capaaimr :�\i„�l.\!\. .. .�\.(�\_+v\ �\.�\� �:'/..„\J�\f�\:/U\i;�✓\J.�l,:\�.v„✓,\..\.%/„Cv\!-�:/„`iJ.`:�Ci„C �,C•",;�: ichm Manville Co wo,ion• P.O. Box 5100, Denver, CO BU17.5108, Inlemee hupffwww.lm.com. For more Inlormmion call 1-100854-3103, 04/16/2002 10:39 3216770285 RICK DOOLEY MACK PAGE 06 n REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATE: / / ST. LUCIE COUNTY I3LDG. & ZONING 23110 VIRGINIA AVE ---IIF �Ft17�rt I I R CE, FL 34952-5652 PERMIT NUMBER: _V ,� Ph. (561) 462-2165 to APR 16 2002 :FAX (561) 462-1148 PROPERTY ADDRESS: s .s �07�fS- 41 u St. Lucie County Public Works * 64,k D THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO EX CEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release in requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by ail terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. All conditions and requirements listed in the attached document entitled 'Requirements for 30 Day Power for Testing" have been fulfilled and the premises is ready for compliance inspection. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST'. LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL LIABILITIES AND CLAIM:; OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGES WHICH MAY BE IIQCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER IN THE EVENT DF VIOLATION OF THIS AGREEMENT. n PSL, L OWNER & Mack Const CONTRACTOR SIGNATURE CED Pp � r� 7 OSVZ� D E &T DUNKELBERGER ENGINSftG & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self-Storag ' Report Date: 1 1-09-01 Port St. Lucie, Florida �~ Client Name: PSL, Ltd. I 1800 Bering Drive, Suite 1010 Houston, Texas 77057 JAN 0 4 2002 " Project No.: Date Tested: 01-10-11 10 10-16-01 Attn: Mr. John C. West, President St. Lucie County Public VJor, ¢Technician Initials: _o ress Report No.: SM 1 (Sheet I of 10 Laborator Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 1 1 1.5 11.2 113.5 1 - - - 9.8 100 100+ Pass 2 12 1 1 1.5 11.2 112.8 - - - 10.5 100 100+ Pass 3 12 1 1 1.5 11.2 113.0 - - - 9.0 1 100 100+ Pass 4 12 111.5 11.2 111.9 11.3 100 100+ 1 Pass 5 12 1 1 1.5 11.2 112.2 - - - 9.4 100 100+ Pass 'type of Field Density'resC O AS'I'M 1) 1556 (X) AS'1•M D 2922 O AS'rM D 2937 Minimum Required Compaction Based on: O AASH'1'O T-f80 (AS'I'M D 1557) (X) AASH,r0'1'-99 (AS'rM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model 5-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 1 6 11.5 West side of 5-02, north side of pipe 2 6 11.5 East side of S-01, south side of pipe 3 6 11.5 South side of 5-01, east side of pipe 4 6 11.5 100' south of 5-01, west side of pipe 5 6 11.5 200' south of 5-01, east side of pipe Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2. Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8• Stabilized Subgrade 9 Base Course 10 Other: cc: Kimley-Horn, Inc. (Stuart), Mr. Mike Grezlka, P.E.... (1) Edgecomb & Associates, Mr. Clark Edgecomb... (1) Dooley & Mack Construction, Mr. Vince Gorman ... (1) Craig E. Dunkel FL Registration ADY 14 2 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 11-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1 110 Houston, Texas 77057 Date Tested: 10-16-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: I (Sheet 2 of 10) Laborator Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 6 12 I 1 1.5 11.2 113.7 - - - 11.0 100 100+ Pass 7 12 1 1 1.5 11.2 1 1 1.8 - - - 9.9 100 100+ Pass 8 12 1 1 1.5 11.2 112.4 - - - 11.9 100 100+ Pass 9 12 1 1 1.5 11.2 113.3 - - - 10.7 100 100+ Pass 10 12 1 1 1.5 11.2 114.0 - - - 12.0 100 100+ Pass 11 12 1 1 1.5 11.2 112.7 - - - 10.2 100 100+ Pass 12 12 1 1 1.5 11.2 112.1 - - - 9.5 100 100+ Pass 13 12 111.5 II.2 II3.9 10.7 100 100+ Pass 14 12 1 1 1.5 11.2 112.4 ... -- 100 100+ Pass. Type of Field Density Test: O ASTM 1) 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: O AASH'1'0 T-I80 (AS'I'M 1) 1557) (X) AASH'1-0 T-99 (ASTM D 698) 'Compaction percent estimated from cane penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location 6 6 12.5 West side of S-02 7 6 12.5 East side of S-01 8 6 12.5 South side of S-01 9 6 12.5 100' south of S-01 10 ' 6 12.5 200' south of S-01 11 6 13.5 West side of S-02 12 6 13.5 East side of S-01 13 6 13.5 South side of S-01 14 6 13.5 100' south of S-01 Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 . Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7- Roadway Subgrade 8 Stabilized Subgrade 9 Base Course • 10 Other: cc: FL Registration No. NQY 14 200'ytj 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) Y4 State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 1 1-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 10-17-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: I Sheet 3 of 10 Laboratory Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Densit Test Result 1 12 1 1 1.5 11.2 1 1 1.7 - - - 12.4 100 100+ Pass 2 12 1 1 1.5 11.2 112.8 - - - 9.5 100 100+ Pass 3 12 1 1 1.5 11.2 114.2 - - - 10.3 100 100+ Pass 4 12 1 1 1.5 1 11.2 112.0 - - - 9.3 100 100+ Pass 5 12 1 1 1.5 11.2 113.7 - - - 9.9 100 100+ Pass 6 12 1 1 1.5 11.2 113.2 - - - 10.4 100 100+ Pass Type of Field Density Test O ASI'M 1) 1556 (X) ASI'M 1) 2922 O ASI'M D 2937 Minimum Required Compaction Based on: O AASFI'f0-1'-I80 (ASTM D 1557) (X) AASH'1-0 T-99 (ASfM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. soil Type Elevation Test Location 1 6 13.5 200' south of S-01 2 - 6 14.5 West side of S-02 3 6 14.5 East side of S-01 4 6 14.5 South side of S-01 5 - 6 14.5 100' south of S-01 6 6 14.5 200' south of S-01 Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type I. Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: cc: lJ Craig E. Dunkelbe FL Registration N N 141 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 11-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 10-29-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: I (Sheet 4 of 10 Laboratory Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result I 12 113.8 9.2 114.7 - - - 9.7 95 100+ Pass 2 12 113.8 9.2 106.5 - - - 10.1 95 93.6 Fail 3 12 113.8 9.2 105.9 --- 11.4 95 93.1 Fail 'rype or Field Density'1'esC O ASTM 1) 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASI1'I'0'r-180 (ASTM D 1557) O AASH"r0 T-99 (ASTM D 698) 'Compaction percent estimated Rom cone penetrometer reading obtained with a Brainard-Kilman Model 5-214 hand-held cone penetrometer. Test No. Soil Tvpe Elevation Test Location 1 10 13.5 Proposed office building, center of pad 2 ' 10 14.5 60' east and 45' north of southwest comer of Building "D" 3 10 14.5 Northwest comer of Building "B" Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1- Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 . Base Course 10 Other: Stripped Grade cc: raig E. Dugnnkelbeerger, FL Regllttl6 to 1�3 4 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 1 1-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 1'0-30-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: 1 (Sheet 5 of 10) Laborato Proctor Field Tests Test No. Probe Depth in Maximum Dry Density c Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 1 12 113.8 9.2 110.4 - - - 10.4 95 97.0 Pass 2 12 1 13.8 9.2 - - - 40 - - - 95 95 Pass 3 12 1 113.8 9.2 110.8 - - - 10.1 95 97.4 Pass 4 12 113.8 9.2 --- 35 95 95 Pass 5 12 113.8 9.2 109.1 9.7 95 95.9 Pass 6 12 1 13.8 9.2 - - - 40 - - - 95 95 Pass 7 12 113.8 9.2 1 1 1.0 - - - 9.5 95 97.5 Pass 8 12 113.8 9.2 --- 40 --- 95 95 Pass 'type of Field Density Test: O ASTM D 1556 (X) ASTM D 2922 O ASTM 1) 2937 Minimum Required Compaction Based on: (X) AAS[IT0 T-I80'(AS 'I'M D 1557) O AASHTO T-99 (ASTM D 698) 'Compaction percent estimated I}om cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location: Building B 1 1 14.5 Southeast corner 2 10 13.5 Southeast comer 3 1 14.5 60' south and 60' east of northwest corner 4 10 13.5 60' south and 60' east of northwest comer 5 1 14.5 Northwest corner RETEST of #3, 10-29-01 6 10 13.5 Northwest comer 7 I 14.5 Northeast corner 8 10 13.5 Northeast comer Elovation Referenced to: (X) NGVD ( ) MSL ( ) Other --- Soil T ype 1- Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 . Base Course 10 Other: Stripped Grade cc: FL RegistrKt y NV. 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) State of Florida Board of Professional Engineers Authorization No. 6870 DE&T DUNK' ELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 1 1-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1 1 10 Houston, Texas 77057 Date Tested: 10-30-01 Technician Initials: SM .Attn: Mr. John C. West, President Pro ress Report No.: I (Sheet 7 of 10) Laborato Proctor Field Tests Minimum Probe Maximum Optimum Dry Cone Required Percent Test Depth Dry Density Moisture Density Resistance' Moisture Compaction Maximum Test No. in c % c is % % Density Result 13 12 113.8 9.2 112.3 - - - 10.3 95 98.7 Pass 14 12 113.8 9.2 --- 40 --- 95 95 Pass 15 12 1 113.8 9.2 113.5 --- 9.8 95 99.7 Pass 16 12 113.8 9.2 --- 40 --- 95 95 Pass 17 12 1 13.8 9.2 110.7 - - - 9.2 95 97.3 Pass 18 12 113.8 9.2 --- 40 --- 95 95 Pass 19 12 113.8 9.2 112.7 - - - 10.5 95 99.0 Pass 20 12 1 13.8 9.2 - - - 40 - - - 95 95 Pass Type of Field Density'rest: 0 ASTM 1) 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASFITO I-180 (ASTM D 1557) O AASHTO T-99 (ASTM D 698) 'Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No: Elevation Test Location: BuildingD 13 14.5 Northeast comer 14 13.5 Northeast corner 15 14.5 25' east and 10' south of northwest corner 16 13.5 25' east and 10' south of northwest comer 17 15 14.5 10' north and 10' west of southeast corner 18 10 13.5 10' north and 10' west of southeast corner 19 I 14.5 70' south and 20' east of northwest comer ' 20 10 13.5 70' south and 20' east of northwest corner Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade A • Stabilized Subgrade 9 Base Course 10 Other: Stripped Grade cc: !✓Craig E. Dunkelberger, FL Registration No 4 NOV � 12GOi 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (56t)^34 -9404 State of Florida Board of Professional Engineers Authorization No. 6870 D E &T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: 1 1-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite IWO Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 10-30-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: I (Sheet 8 of 10 Laborato Proctor Field Tests Test No. Probe Depth in Maximum Dry Density e Optimum Moisture % Dry Density c Cone Resistance' is Moisture % Minimum Required Compaction % Percent Maximum Density Test Result 21 12 113.8 9.2 110.9 - - - 9.4 95 97.5 Pass 22 12 113.8 9.2 - - - 40 - - - 95 95 Pass 23 12 113.8 9.2 114.1 --- 9.8 95 100+ Pass 24 12 113.8 9.2 --- 40 --- 95 95 Pass 'Type of Held Density'I'est: O ASTM 1) 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASII'T0 T-180 (ASTM D 1557) O AASH'1-0 T-99 (ASTM D 698) 'Compaction percent estimated Itom cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No. Soil Type Elevation Test Location: Building D 21 1 14.5 Southwest comer 22 - 10 13.5 Southwest corner 23 1 14.5 60' east and 45' north of southwest comer RETEST of f12, 10-29-01 24 10 13.5 60' east and 45' north of southwest corner Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other Soil Type 1 . Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm • 7• Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Stripped Grade cc: FL Registration NOV 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 3 State of Florida Board of Professional Engineers Authorization No. 6870 i DRY UNIT WEIGHT POUNDS PER CUBIC FOOT 4 6 8 10 12 14 WATER CONTENT --- PERCENT OF DRY WEIGHT MOISTURE - DENSITYRELATIO. Sample Location: On -site, building pad fill Proposed Guardian Self -Storage Port St. Lucie, Florida Sample Description: Brown fine to medium SAND, slightly silty, trace clay (-200: 10.4%) an DET ��,...��o��.. GeoteeLniml•MrtesrideTcdd Tested By: KM/RM Date: VM -()I Checked Bv: CD Date: I I-08-01 :ESULTS T-180 113.8 9.2 SP-SM 3510 Sheet: 9 of DE&T I I,Odt32 DRY UNIT WEIGHT POUNDS PER CUBIC FOOT 6 8 10 12 14 16 WATER CONTENT --- PERCENT OF DRY WEIGHT Sample Location: On -site, pipe backfill Sample Description: Brown tine to medium SAND, TTT slightly silty, trace clay LEI 1 (-200: 8.6%) 1 Tested BY: 'VAZ - "z1yallI l[CLHIIVI Proposed Guardian Self -Storage Port St. Lucie, Florida KM/RM Date: 10-23-01 CD Date: II-08-01 :ESULTS T-99 111.5 11.2 SP-SM 3521 DIDGIIQ DE&T IIIUdl32 D E &T DUNKELBERGER ENGIN°EERING & TESTING, INC. (/i '1 : Proposed Guardian Self-Stor Y" Port St. Lucie, Florida Report Date: I I-09-01 PSL, Ltd. LAttn:' Bering Drive, Suite 1010 \ Houston, Houston, Texas 77057 ` 1� (Y @ua� Project No.: ' 01-10-1110 Date Tested: r30 OI Mr. John C. West, President Technician Initials: SM Progress Report No.: I (Sheet 7 of I Laborato Proctor Field Tests Probe Maximum Optimum Dry Cone Minimum Test No. Depth in Dry Density Moisture Density Resistance' Reqred Percent Moisture Compaction Maximum 13 12 113.8 9.2 112.3 % % Densit Test Resul 14 12 113.8 9.2 --- 40 10.3 95 98.7 Pass 15 12 113.8 9.2 113.'. 5 _ _ --- 9'8 95 95 �PaSS: 16 12 113.8 9.2 40 95 99.7 s 17 12 113.8 9.2 9'2 95 95 18 12 113.8 9.2 40 95 97.3 19 12 113.8 9.2 112.7 10.5 95 95 95 Rass� 20 12 113.8 9.2 99.0 �P us 'rype of Field Density Test: () ASI'M D 1556 (X) ASTM D 2922 Compaction Based on: (X) AASH'1'0'1'-18u (ASTD 1557) Minimum-Required1) AS'fM D 2937 'Compaction percent estimated from cone (1 AASH'fO T-99 (ASfM D 698) penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test Soil No. T e Elevation 13 Test Location: aiidin D 1 14.5 Northeast corner 14 10 13.5 Northeast comer 15 . 1 14.5 25' east and 10' south of northwest corner 16 10 13.5 25' east and I O'south of northwest corner 17 1 14.5 10' north and 10' west of southeast corner 18 10 13.5 10'north and 10' west of southeast corner 19 1 14.5 70'south and 20' east of northwest corner 20 10 13.5 70' south and 20' east of northwecr Elevation Referenced to: (X) NGVD () MSL () Other I Structural FIII 2 Final Grading Fill 3 Mass Grading Fill a4 Utility Backfll - Sanitary 5 Utility-Backfill - Water 6 Utility Backfill - Storm 7- Roadway Subgrade S -Stabilized Subgrade 9 Base Course cc: r: Stripped Grade I IJCraig E. Dunkelberg FL Registration No. i'Vi 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 . Fax: (56t)-34 State of Florida Board of Professional Engineers Authorization No. 6870 DE&T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Proposed Guardian Self -Storage Report Date: I 1-09-01 Port St. Lucie, Florida Client Name: PSL, Ltd. 1800 Bering Drive, Suite 1010 Project No.: 01-10-1110 Houston, Texas 77057 Date Tested: 10-30-01 Technician Initials: SM Attn: Mr. John C. West, President Progress Report No.: I (Sheet 8 of 10) Laborato Proctor Field Tests Test No. 21 22 23 24 Probe Depth in 12 12 12 12 Maximum Dry Density c 113.8 113.8 II3.8 113.8 Optimum Moisture % 9.2 9.2 9.2 9.2 Dry Density c 110.9 _ - - 114.1 --- Cone Resistance' is - - - 40 Moisture % 9.4 - - - Minimum Required Compaction % 95 95 95 95 Percent Maximum DensityResult 97.5 95 I00+ 95 Test [P-assJ Pass 6P-ass=-� W40- Type of field Density Test: 0 ASTM D 1556 (X) ASTM D 2922 0 AS"1'M D 2937 Minimum Required Compaction Based on: (X) AAS11TO T-180 (ASTM 1) 1557) 0 AASHTO T-99 (ASTM O 698) 'Compaction percent estimated from cone penetrometer reading ohtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Test No: Soil T e Test Location: wild n M 21 1 .5 Southwest corner22 10 jElevation .5 Southwest corner23 1 .5 60'east and 45' north of southwest corner (RETEST of H2, 10-29-0124 10 .5 60' east and 45' north of southwest corner Elevation Referenced to: (X) NGVD ( ) MSL ( ) Other I Soil Tvoe I I Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water .6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course Grade cc: Craig E. Dunkel FL Registration 523A NW Enterprise Drive, Port St. Lucie, Florida 34986 • Phone: (561) 343-9787 • Fax: (561) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870