HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATIONNOTICE 01 � `'RODUCT CERTIFICA . -ON
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
REVISION DATE:
NI011110.01-R1
05/22/2012
Structural
JELD-WEN
822-1
01/04/2016
To verify that the "Notice of Product Certification" is valid, please visit www.NAMTCertificatioti.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME -AND ADDRESS
PRODUCT DESCRIPTION
JELD-WEN
"Premium Atlantic Aluminum Sliding
3737 Lakeport Boulevard
Patio Door" Sliding Glass Door
Klamath Falls, OR 97601
Configuration: XXXXX
SCANNEDInsulating
Gluing: Monolithic (Tempered) or
Glass (Tempered)
BY
St. Lucie County
Frame: W-3026mm(237.25") H-2438mm(96")
Panel: W-1257mm(49.5") H-2381mm(93.75")
SPECIFICATION PRODUCT RATING
TAS 202-94 Design Pressure: +80/-80 psf
Product Tested By: National Certified Testing Laboratories, Inc.
Report No: NCTL-210-3382-2
Expiration Date: February 28, 2020
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax:(804) 684-5122
NOTICE Of .i RODUCT CERTIFICA';i 'ON
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
REVISION DATE:
NI011110.02-111
05/22/2012
Structural
JELD-WEN
822-1
01/04/2016
To verify that the "Notice of Product Certification" is valid, please visit www.NAMTCertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
JELD-WEN
"Premium Atlantic Aluminum Sliding
3737 Lakeport Boulevard
Patio Door" Sliding Glass Door
Klamath Falls, OR 97601
Configuration: XXX
Glazing. Laminate-3/16" Heat Strengthened Glass/0.090"
SentryGlass Plus/3/16" Heat Strengthened Glass or IG-3/16"
Tempered Glzss/Urninate-3/16" Heat Strengthened Glass/0.090"
SentryGlas Plus/3/I6" Heat Strengthened Glass
Frame: W-3626mm(142.75") H-2438mm(96")
Panel: W-1257rnm(49.5") H-2381mm(93.75")
SPECIFICATION
PRODUCT RATING
TAS 201/202/203-94
Design Pressure: +80/-80 psf
Large Missile Impact Rated
Product Tested By:
Report No:
Expiration Date:
National Certified Testing Laboratories, Inc.
NCTL-210-3382-3
February 28, 2020
Administrator's Signature:
..;;04.rD
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax:(804) 684-5122
,- I
NOTICE 01 �4tRODUCT CERTIFICA. 'ON
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
REVISION DATE:
NI011110.04-11I
05/22/2012
Structural
JELD-WEN
822-1
01/04/2016
To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
JELD-WEN
"Premium Atlantic Aluminum Sliding
3737 Lakeport Boulevard
Patio Door" Sliding Glass Door
Klamath Falls, OR 97601
Configuration: OXXXXX
Glazing: Monolithic (Tempered) or
Insulating Glass (Tempered)
Frame: W-7201mm(283.5") H-2438mm(96")
Panel: W-1257mm(49.5") 1-1-2407mm(94.75")
SPECIFICATION PRODUCT RATING
TAS 202-94 Design Pressure: +80/-80 psf
Product Tested By:
Report No:
Expiration Date:
National Certified Testing Laboratories, Inc.
NCTL-210-3360-2.
May 31, 2020
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122